000060217 001__ 60217
000060217 005__ 20240712101011.0
000060217 0247_ $$2Handle$$a2128/20625
000060217 037__ $$aPreJuSER-60217
000060217 0881_ $$aJuel-3796
000060217 088__ $$2JUEL$$aJuel-3796
000060217 1001_ $$0P:(DE-Juel1)16203$$aSmit, Herman G. J.$$b0$$uFZJ
000060217 245__ $$aEnvironmental simulation facility to calibrate airborne ozone and humidity sensors
000060217 260__ $$aJülich$$bForschungszentrum Jülich GmbH Zentralbibliothek, Verlag$$c2000
000060217 300__ $$aVII, 31 p.
000060217 3367_ $$0PUB:(DE-HGF)3$$2PUB:(DE-HGF)$$aBook
000060217 3367_ $$2DRIVER$$abook
000060217 3367_ $$01$$2EndNote$$aBook
000060217 3367_ $$2DataCite$$aOutput Types/Book
000060217 3367_ $$2ORCID$$aBOOK
000060217 3367_ $$2BibTeX$$aBOOK
000060217 4900_ $$0PERI:(DE-600)2414853-2$$81362$$aBerichte des Forschungszentrums Jülich$$v3796$$x0944-2952
000060217 500__ $$aRecord converted from VDB: 12.11.2012
000060217 520__ $$aThe Environmental Simulation Facility established at the Forschungszentrum Jülich (FZJ) is designed to investigate the performance of different types of balloon borne sensors as well as air borne humidity sensors to measure the vertical distribution of atmospheric ozone and water vapor, respectively. Key component of the facility is a temperature and pressure controlled simulation chamber with a test room volume of about 500 liter (80x80x80 cm) whereby pressure as well as temperature can be dynamically regulated between 5 and 1000 hPa and between 200 and 300 K (-2K/min $\le$ rate $\le$ +2K/min) respectively. The volume mixing ration of ozone can be dynamically regulated between 5 and 10000 ppbv up to a simulation altitude of about 35 km. The relative humidity in the chamber can be varied from about 95 % down to 2 % over a temperature range between +30$^{\circ}$C and -70$^{\circ}$C and pressure range between 1000 and 100 hPa. Ozone and humidity sensing devices can be calibrated against accurate reference instruments. A fast response dual beam UV-photometer serves as ozone reference. For the calibration of the water vapor sensors a dew point hygrometer is used for lower/middle tropospheric humidity conditions, while for middle/upper tropospheric conditions a Lyman ($\alpha$) fluorescence hygrometer seves as reference. The entire simulation process is computer controlled to provide reproducible conditions with respect to pressure, temperature, ozone concentration and humidity. Since 1994 the chamber is used for the regular (monthly) calibration of water vapor sensing devices which are flown aboard 5 civil "in-service" aircraft (Airbus-A340) within the frame of the European project MOZAIC (Measurement of Ozone and Water Vapor on Airbus In-Service Aircraft) for automatic monitoring of the water vapor distribution in the troposphere. The facility is also established as World Calibration Facility for Ozone Sondes (WCFOS) as part of the Global Atmosphere Watch (GAW) profram of the World Meteorological Organization (WMO). In the scope of this frame work several intercomparison experiments, JOSIE (= Jülich Ozone Sonde Intercomparison Experiment), were conducted to assess the performance of the major types of ozone sondes used within the global network of ozone sounding stations. Furthermore, the facility serves as platform to investigate the performance of new developed airborne sensing devices.
000060217 536__ $$0G:(DE-Juel1)FUEK72$$2G:(DE-HGF)$$aChemie der Belasteten Atmosphäre$$c36.20.0$$x0
000060217 7001_ $$0P:(DE-Juel1)VDB1594$$aSträter, Wolfgang$$b1$$uFZJ
000060217 7001_ $$0P:(DE-Juel1)VDB589$$aHelten, Manfred$$b2$$uFZJ
000060217 7001_ $$0P:(DE-Juel1)16204$$aKley, Dieter$$b3$$uFZJ
000060217 8564_ $$uhttps://juser.fz-juelich.de/record/60217/files/J%C3%BCl_3796_Smit.pdf$$yOpenAccess
000060217 8564_ $$uhttps://juser.fz-juelich.de/record/60217/files/J%C3%BCl_3796_Smit.pdf?subformat=pdfa$$xpdfa$$yOpenAccess
000060217 909CO $$ooai:juser.fz-juelich.de:60217$$pdnbdelivery$$pdriver$$pVDB$$popen_access$$popenaire
000060217 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000060217 9141_ $$y2000
000060217 9131_ $$0G:(DE-Juel1)FUEK72$$bUmweltvorsorgeforschung$$k36.20.0$$lUmweltforschung$$vChemie der Belasteten Atmosphäre$$x0
000060217 9201_ $$0I:(DE-Juel1)VDB52$$d31.12.2001$$gICG$$kICG-2$$lChemie der belasteten Atmosphäre$$x0
000060217 970__ $$aVDB:(DE-Juel1)9445
000060217 9801_ $$aFullTexts
000060217 980__ $$aVDB
000060217 980__ $$aConvertedRecord
000060217 980__ $$abook
000060217 980__ $$aI:(DE-Juel1)IEK-8-20101013
000060217 980__ $$aUNRESTRICTED
000060217 981__ $$aI:(DE-Juel1)ICE-3-20101013
000060217 981__ $$aI:(DE-Juel1)IEK-8-20101013