001     60217
005     20240712101011.0
024 7 _ |2 Handle
|a 2128/20625
037 _ _ |a PreJuSER-60217
088 1 _ |a Juel-3796
088 _ _ |a Juel-3796
|2 JUEL
100 1 _ |0 P:(DE-Juel1)16203
|a Smit, Herman G. J.
|b 0
|u FZJ
245 _ _ |a Environmental simulation facility to calibrate airborne ozone and humidity sensors
260 _ _ |a Jülich
|b Forschungszentrum Jülich GmbH Zentralbibliothek, Verlag
|c 2000
300 _ _ |a VII, 31 p.
336 7 _ |0 PUB:(DE-HGF)3
|2 PUB:(DE-HGF)
|a Book
336 7 _ |2 DRIVER
|a book
336 7 _ |0 1
|2 EndNote
|a Book
336 7 _ |2 DataCite
|a Output Types/Book
336 7 _ |2 ORCID
|a BOOK
336 7 _ |2 BibTeX
|a BOOK
490 0 _ |0 PERI:(DE-600)2414853-2
|8 1362
|a Berichte des Forschungszentrums Jülich
|v 3796
|x 0944-2952
500 _ _ |a Record converted from VDB: 12.11.2012
520 _ _ |a The Environmental Simulation Facility established at the Forschungszentrum Jülich (FZJ) is designed to investigate the performance of different types of balloon borne sensors as well as air borne humidity sensors to measure the vertical distribution of atmospheric ozone and water vapor, respectively. Key component of the facility is a temperature and pressure controlled simulation chamber with a test room volume of about 500 liter (80x80x80 cm) whereby pressure as well as temperature can be dynamically regulated between 5 and 1000 hPa and between 200 and 300 K (-2K/min $\le$ rate $\le$ +2K/min) respectively. The volume mixing ration of ozone can be dynamically regulated between 5 and 10000 ppbv up to a simulation altitude of about 35 km. The relative humidity in the chamber can be varied from about 95 % down to 2 % over a temperature range between +30$^{\circ}$C and -70$^{\circ}$C and pressure range between 1000 and 100 hPa. Ozone and humidity sensing devices can be calibrated against accurate reference instruments. A fast response dual beam UV-photometer serves as ozone reference. For the calibration of the water vapor sensors a dew point hygrometer is used for lower/middle tropospheric humidity conditions, while for middle/upper tropospheric conditions a Lyman ($\alpha$) fluorescence hygrometer seves as reference. The entire simulation process is computer controlled to provide reproducible conditions with respect to pressure, temperature, ozone concentration and humidity. Since 1994 the chamber is used for the regular (monthly) calibration of water vapor sensing devices which are flown aboard 5 civil "in-service" aircraft (Airbus-A340) within the frame of the European project MOZAIC (Measurement of Ozone and Water Vapor on Airbus In-Service Aircraft) for automatic monitoring of the water vapor distribution in the troposphere. The facility is also established as World Calibration Facility for Ozone Sondes (WCFOS) as part of the Global Atmosphere Watch (GAW) profram of the World Meteorological Organization (WMO). In the scope of this frame work several intercomparison experiments, JOSIE (= Jülich Ozone Sonde Intercomparison Experiment), were conducted to assess the performance of the major types of ozone sondes used within the global network of ozone sounding stations. Furthermore, the facility serves as platform to investigate the performance of new developed airborne sensing devices.
536 _ _ |0 G:(DE-Juel1)FUEK72
|2 G:(DE-HGF)
|a Chemie der Belasteten Atmosphäre
|c 36.20.0
|x 0
700 1 _ |0 P:(DE-Juel1)VDB1594
|a Sträter, Wolfgang
|b 1
|u FZJ
700 1 _ |0 P:(DE-Juel1)VDB589
|a Helten, Manfred
|b 2
|u FZJ
700 1 _ |0 P:(DE-Juel1)16204
|a Kley, Dieter
|b 3
|u FZJ
856 4 _ |u https://juser.fz-juelich.de/record/60217/files/J%C3%BCl_3796_Smit.pdf
|y OpenAccess
856 4 _ |u https://juser.fz-juelich.de/record/60217/files/J%C3%BCl_3796_Smit.pdf?subformat=pdfa
|x pdfa
|y OpenAccess
909 C O |o oai:juser.fz-juelich.de:60217
|p openaire
|p open_access
|p VDB
|p driver
|p dnbdelivery
913 1 _ |0 G:(DE-Juel1)FUEK72
|b Umweltvorsorgeforschung
|k 36.20.0
|l Umweltforschung
|v Chemie der Belasteten Atmosphäre
|x 0
914 1 _ |y 2000
915 _ _ |0 StatID:(DE-HGF)0510
|2 StatID
|a OpenAccess
920 1 _ |0 I:(DE-Juel1)VDB52
|d 31.12.2001
|g ICG
|k ICG-2
|l Chemie der belasteten Atmosphäre
|x 0
970 _ _ |a VDB:(DE-Juel1)9445
980 1 _ |a FullTexts
980 _ _ |a VDB
980 _ _ |a ConvertedRecord
980 _ _ |a book
980 _ _ |a I:(DE-Juel1)IEK-8-20101013
980 _ _ |a UNRESTRICTED
981 _ _ |a I:(DE-Juel1)ICE-3-20101013
981 _ _ |a I:(DE-Juel1)IEK-8-20101013


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21