Home > Publications database > Layout and performance of the polarizing guide system for the J-NSE spectrometer at the FRM II > print |
001 | 61163 | ||
005 | 20240619091941.0 | ||
024 | 7 | _ | |2 DOI |a 10.1016/j.nima.2007.11.038 |
024 | 7 | _ | |2 WOS |a WOS:000253845300020 |
024 | 7 | _ | |2 MLZ |a Holderer2008 |
037 | _ | _ | |a PreJuSER-61163 |
041 | _ | _ | |a eng |
082 | _ | _ | |a 530 |
084 | _ | _ | |2 WoS |a Instruments & Instrumentation |
084 | _ | _ | |2 WoS |a Nuclear Science & Technology |
084 | _ | _ | |2 WoS |a Physics, Particles & Fields |
084 | _ | _ | |2 WoS |a Spectroscopy |
100 | 1 | _ | |0 P:(DE-Juel1)130718 |a Holderer, O. |b 0 |u FZJ |
245 | _ | _ | |a Layout and performance of the polarizing guide system for the J-NSE spectrometer at the FRM II |
260 | _ | _ | |a Amsterdam |b North-Holland Publ. Co. |c 2008 |
300 | _ | _ | |a 90 - 94 |
336 | 7 | _ | |a Journal Article |0 PUB:(DE-HGF)16 |2 PUB:(DE-HGF) |
336 | 7 | _ | |a Output Types/Journal article |2 DataCite |
336 | 7 | _ | |a Journal Article |0 0 |2 EndNote |
336 | 7 | _ | |a ARTICLE |2 BibTeX |
336 | 7 | _ | |a JOURNAL_ARTICLE |2 ORCID |
336 | 7 | _ | |a article |2 DRIVER |
440 | _ | 0 | |0 4642 |a Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment |v 586 |x 0168-9002 |y 1 |
500 | _ | _ | |a Record converted from VDB: 12.11.2012 |
520 | _ | _ | |a The neutron spin-echo instrument, J-NSE, that has been moved from the ELLA guide hall at the FRJ-2 in Julich to the guide hall of the new FRM II reactor, needs an intense beam of polarized neutrons. Polarization of the short wavelengths is achieved in a bent section of about 8 m and radius 160 m, with a m = 3 FeSi multilayer coating. Due to the total reflection of Fesi, longer wavelengths (lambda similar or equal to 10-20 (A) over circle) pass unpolarized and need an additional short polarizer at the entrance of the instrument. After the bent section within a 10 m straight guide section a turn of vertical polarization to longitudinal guide field is performed and a selector is inserted. Then about 10m of tapered Ni-58 covered guide follows, which end with a cross-section of 60 x 60 mm(2). We present the design criteria and first measurements on the performance of this guide concept. (c) 2007 Elsevier B.V. All rights reserved. |
536 | _ | _ | |0 G:(DE-Juel1)FUEK414 |2 G:(DE-HGF) |a Kondensierte Materie |c P54 |x 0 |
536 | _ | _ | |0 G:(DE-Juel1)FUEK415 |a Großgeräte für die Forschung mit Photonen, Neutronen und Ionen (PNI) |c P55 |x 1 |
588 | _ | _ | |a Dataset connected to Web of Science |
650 | _ | 7 | |2 WoSType |a J |
653 | 2 | 0 | |2 Author |a neutron guide |
653 | 2 | 0 | |2 Author |a polarization |
653 | 2 | 0 | |2 Author |a neutron spin-echo |
693 | _ | _ | |0 EXP:(DE-MLZ)J-NSE-20140101 |1 EXP:(DE-MLZ)FRMII-20140101 |5 EXP:(DE-MLZ)J-NSE-20140101 |6 EXP:(DE-MLZ)NL2ao-20140101 |a Forschungs-Neutronenquelle Heinz Maier-Leibnitz |e J-NSE: Neutron spin-echo spectrometer |f NL2ao |x 0 |
693 | _ | _ | |0 EXP:(DE-MLZ)NO-20140101 |6 EXP:(DE-MLZ)NO-20140101 |f Neutron Optics |x 1 |
700 | 1 | _ | |0 P:(DE-Juel1)VDB73596 |a Monkenbusch, M |b 1 |u FZJ |
700 | 1 | _ | |0 P:(DE-HGF)0 |a Borchert, G. |b 2 |
700 | 1 | _ | |0 P:(DE-HGF)0 |a Breunig, C. |b 3 |
700 | 1 | _ | |0 P:(DE-HGF)0 |a Zeitelhack, K. |b 4 |
773 | _ | _ | |0 PERI:(DE-600)1466532-3 |a 10.1016/j.nima.2007.11.038 |g Vol. 586, p. 90 - 94 |p 90 - 94 |q 586<90 - 94 |t Nuclear instruments & methods in physics research / A |v 586 |x 0168-9002 |y 2008 |
856 | 7 | _ | |u http://dx.doi.org/10.1016/j.nima.2007.11.038 |
909 | C | O | |o oai:juser.fz-juelich.de:61163 |p VDB |
913 | 1 | _ | |0 G:(DE-Juel1)FUEK414 |b Materie |k P54 |l Kondensierte Materie |v Kondensierte Materie |x 0 |z entfällt bis 2009 |
913 | 1 | _ | |0 G:(DE-Juel1)FUEK415 |b Struktur der Materie |k P55 |l Großgeräteforschung mit Photonen, Neutronen und Ionen |v Großgeräte für die Forschung mit Photonen, Neutronen und Ionen (PNI) |x 1 |
914 | 1 | _ | |y 2008 |
915 | _ | _ | |0 StatID:(DE-HGF)0010 |a JCR/ISI refereed |
920 | 1 | _ | |0 I:(DE-Juel1)VDB785 |d 31.12.2010 |g IFF |k IFF-5 |l Neutronenstreuung |x 0 |
920 | 1 | _ | |0 I:(DE-Juel1)VDB784 |d 31.12.2010 |g IFF |k IFF-4 |l Streumethoden |x 1 |
920 | 1 | _ | |0 I:(DE-Juel1)JCNS-20121112 |k Jülich Centre for Neutron Science JCNS (JCNS) ; JCNS |l JCNS |x 2 |
970 | _ | _ | |a VDB:(DE-Juel1)95841 |
980 | _ | _ | |a VDB |
980 | _ | _ | |a ConvertedRecord |
980 | _ | _ | |a journal |
980 | _ | _ | |a I:(DE-Juel1)ICS-1-20110106 |
980 | _ | _ | |a I:(DE-Juel1)PGI-4-20110106 |
980 | _ | _ | |a I:(DE-Juel1)JCNS-1-20110106 |
980 | _ | _ | |a UNRESTRICTED |
980 | _ | _ | |a I:(DE-Juel1)JCNS-2-20110106 |
980 | _ | _ | |a I:(DE-Juel1)JCNS-SNS-20110128 |
980 | _ | _ | |a I:(DE-Juel1)JCNS-ILL-20110128 |
981 | _ | _ | |a I:(DE-Juel1)JCNS-2-20110106 |
981 | _ | _ | |a I:(DE-Juel1)IBI-8-20200312 |
981 | _ | _ | |a I:(DE-Juel1)JCNS-1-20110106 |
981 | _ | _ | |a I:(DE-Juel1)ICS-1-20110106 |
981 | _ | _ | |a I:(DE-Juel1)PGI-4-20110106 |
981 | _ | _ | |a I:(DE-Juel1)JCNS-2-20110106 |
981 | _ | _ | |a I:(DE-Juel1)JCNS-SNS-20110128 |
981 | _ | _ | |a I:(DE-Juel1)JCNS-ILL-20110128 |
Library | Collection | CLSMajor | CLSMinor | Language | Author |
---|