% IMPORTANT: The following is UTF-8 encoded. This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.
@ARTICLE{Babay:61335,
author = {Babay, P. A. and Ale, E. E. R. and Itria, R. F. and
Becquart, E. T. and Thiele, B. and Batistoni, D. A.},
title = {{S}implified determination of lipophilic metabolites of
nonylphenol ethoxylates: method development and application
in aqueous samples from {B}uenos {A}ires, {A}rgentina},
journal = {Journal of environmental monitoring},
volume = {10},
issn = {1464-0325},
address = {London},
publisher = {Royal Society of Chemistry},
reportid = {PreJuSER-61335},
pages = {443 - 452},
year = {2008},
note = {Record converted from VDB: 12.11.2012},
abstract = {In the present work we have developed an analytical
methodology for the determination of nonylphenol (NP) and
nonylphenol mono- and di-ethoxylates (NP1EO and NP2EO) in
water samples. The applicability of this methodology was
proved by means of the analysis of environmentally relevant
aqueous samples from Buenos Aires. This constitutes a
starting point for a rigorous assessment of the incidence of
NPnEO surfactants in Argentina, as only very few,
qualitative or semi-quantitative data on the occurrence of
these compounds in local systems were available up to this
time. Enrichment of the analytes was carried out by
solid-phase extraction on a C-18 sorbent, followed by
elution with ethyl acetate. Normal-phase high performance
liquid chromatography on an amino-silica column and
fluorescence detection at excitation-emission wavelengths of
230-300 nm were employed for separation and quantification
of the analytes. Confirmation of peak assignment in selected
real samples was performed by off-line coupling HPLC with
GC-MS analysis. A non-polar GC capillary column was used,
and a characteristic peak pattern was obtained for the alkyl
chain isomers of each ethoxylated homologue and NP. GC-MS
analyses yielded in all cases purity levels higher than
$80\%$ for the HPLC collected fractions. The elevated
concentrations found for the estrogenic metabolites of NPnEO
are in accordance with an unrestricted use of this class of
non-ionic surfactants in the country.},
keywords = {Argentina / Chromatography, High Pressure Liquid /
Environmental Monitoring: methods / Ethylene Glycols:
analysis / Gas Chromatography-Mass Spectrometry / Solid
Phase Extraction / Surface-Active Agents: analysis / Water
Pollutants, Chemical: analysis / Ethylene Glycols (NLM
Chemicals) / Surface-Active Agents (NLM Chemicals) / Water
Pollutants, Chemical (NLM Chemicals) / terics (NLM
Chemicals) / J (WoSType)},
cin = {ICG-3},
ddc = {333.7},
cid = {I:(DE-Juel1)ICG-3-20090406},
pnm = {Terrestrische Umwelt},
pid = {G:(DE-Juel1)FUEK407},
shelfmark = {Chemistry, Analytical / Environmental Sciences},
typ = {PUB:(DE-HGF)16},
pubmed = {pmid:18385865},
UT = {WOS:000254648300007},
doi = {10.1039/b717942a},
url = {https://juser.fz-juelich.de/record/61335},
}