000807069 001__ 807069
000807069 005__ 20240711085555.0
000807069 0247_ $$2doi$$a10.1007/s00784-015-1585-2
000807069 0247_ $$2ISSN$$a1432-6981
000807069 0247_ $$2ISSN$$a1436-3771
000807069 0247_ $$2WOS$$aWOS:000376403200006
000807069 037__ $$aFZJ-2016-02100
000807069 082__ $$a610
000807069 1001_ $$0P:(DE-HGF)0$$aZingler, Sebastian$$b0$$eCorresponding author
000807069 245__ $$aEfficiency of powered systems for interproximal enamel reduction (IER) and enamel roughness before and after polishing—an in vitro study
000807069 260__ $$aBerlin$$bSpringer$$c2016
000807069 3367_ $$2DRIVER$$aarticle
000807069 3367_ $$2DataCite$$aOutput Types/Journal article
000807069 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1465392652_32490
000807069 3367_ $$2BibTeX$$aARTICLE
000807069 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000807069 3367_ $$00$$2EndNote$$aJournal Article
000807069 520__ $$aObjectiveThis aims to evaluate the efficiency of three different powered interproximal enamel reduction (IER) systems and to assess enamel roughness before and after polishing using different polishing times.Material and methodsFour metal strips of the G5 ProLign Set (swissdentacare, SDC, Grancia, Switzerland), four segmental discs of the ASR-Set 4594 and two sonic tips of the SonicLine Set (both Gebr. Basseler GmbH & Co. KG, Komet, Lemgo, Germany) were evaluated. Human extracted incisors served as the medium. Enamel reduction was determined in five intervals of 15 s each. Polishing was performed for 15 and 30 s using the manufacturers’ recommended polishing systems. Enamel roughness (Ra) was quantitatively assessed by confocal laser scanning microscopy (CLSM).ResultsSignificant differences in terms of enamel reduction were found among the working ends of all tested systems. The time needed to remove 0.1, 0.2 and 0.3 mm of enamel was determined. Surface analysis showed significantly higher mean Ra values for nine out of ten working ends before polishing. This was still the case for five working ends after 15 s and for two after 30 s of polishing.ConclusionThe graining and the system used have a significant influence on enamel reduction. The time needed for polishing depends on the last working end used; a polishing time of 30 s is not always appropriate.Clinical relevanceKnowledge about the cutting efficiency of powered IER working ends might help the clinician to estimate better the amount of enamel reduction during the stripping process.
000807069 536__ $$0G:(DE-HGF)POF3-899$$a899 - ohne Topic (POF3-899)$$cPOF3-899$$fPOF III$$x0
000807069 588__ $$aDataset connected to CrossRef
000807069 7001_ $$0P:(DE-HGF)0$$aSommer, Andreas$$b1
000807069 7001_ $$0P:(DE-HGF)0$$aSen, Sinan$$b2
000807069 7001_ $$0P:(DE-HGF)0$$aSaure, Daniel$$b3
000807069 7001_ $$0P:(DE-HGF)0$$aLanger, Jochen$$b4
000807069 7001_ $$0P:(DE-Juel1)161591$$aGuillon, Olivier$$b5
000807069 7001_ $$0P:(DE-HGF)0$$aLux, Christopher J.$$b6
000807069 773__ $$0PERI:(DE-600)1472578-2$$a10.1007/s00784-015-1585-2$$n5$$p933-942$$tClinical oral investigations$$v20$$x1436-3771$$y2016
000807069 8564_ $$uhttps://juser.fz-juelich.de/record/807069/files/art_10.1007_s00784-015-1585-2.pdf$$yRestricted
000807069 8564_ $$uhttps://juser.fz-juelich.de/record/807069/files/art_10.1007_s00784-015-1585-2.gif?subformat=icon$$xicon$$yRestricted
000807069 8564_ $$uhttps://juser.fz-juelich.de/record/807069/files/art_10.1007_s00784-015-1585-2.jpg?subformat=icon-1440$$xicon-1440$$yRestricted
000807069 8564_ $$uhttps://juser.fz-juelich.de/record/807069/files/art_10.1007_s00784-015-1585-2.jpg?subformat=icon-180$$xicon-180$$yRestricted
000807069 8564_ $$uhttps://juser.fz-juelich.de/record/807069/files/art_10.1007_s00784-015-1585-2.jpg?subformat=icon-640$$xicon-640$$yRestricted
000807069 8564_ $$uhttps://juser.fz-juelich.de/record/807069/files/art_10.1007_s00784-015-1585-2.pdf?subformat=pdfa$$xpdfa$$yRestricted
000807069 909CO $$ooai:juser.fz-juelich.de:807069$$pVDB
000807069 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)161591$$aForschungszentrum Jülich GmbH$$b5$$kFZJ
000807069 9131_ $$0G:(DE-HGF)POF3-899$$1G:(DE-HGF)POF3-890$$2G:(DE-HGF)POF3-800$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bProgrammungebundene Forschung$$lohne Programm$$vohne Topic$$x0
000807069 9141_ $$y2016
000807069 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS
000807069 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bCLIN ORAL INVEST : 2014
000807069 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection
000807069 915__ $$0StatID:(DE-HGF)0111$$2StatID$$aWoS$$bScience Citation Index Expanded
000807069 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5
000807069 915__ $$0StatID:(DE-HGF)0550$$2StatID$$aNo Authors Fulltext
000807069 915__ $$0StatID:(DE-HGF)0310$$2StatID$$aDBCoverage$$bNCBI Molecular Biology Database
000807069 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline
000807069 915__ $$0StatID:(DE-HGF)1110$$2StatID$$aDBCoverage$$bCurrent Contents - Clinical Medicine
000807069 915__ $$0StatID:(DE-HGF)0420$$2StatID$$aNationallizenz
000807069 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bThomson Reuters Master Journal List
000807069 9201_ $$0I:(DE-Juel1)IEK-1-20101013$$kIEK-1$$lWerkstoffsynthese und Herstellungsverfahren$$x0
000807069 9201_ $$0I:(DE-82)080011_20140620$$kJARA-ENERGY$$lJARA-ENERGY$$x1
000807069 980__ $$ajournal
000807069 980__ $$aVDB
000807069 980__ $$aUNRESTRICTED
000807069 980__ $$aI:(DE-Juel1)IEK-1-20101013
000807069 980__ $$aI:(DE-82)080011_20140620
000807069 981__ $$aI:(DE-Juel1)IMD-2-20101013