001     807069
005     20240711085555.0
024 7 _ |a 10.1007/s00784-015-1585-2
|2 doi
024 7 _ |a 1432-6981
|2 ISSN
024 7 _ |a 1436-3771
|2 ISSN
024 7 _ |a WOS:000376403200006
|2 WOS
037 _ _ |a FZJ-2016-02100
082 _ _ |a 610
100 1 _ |a Zingler, Sebastian
|0 P:(DE-HGF)0
|b 0
|e Corresponding author
245 _ _ |a Efficiency of powered systems for interproximal enamel reduction (IER) and enamel roughness before and after polishing—an in vitro study
260 _ _ |a Berlin
|c 2016
|b Springer
336 7 _ |a article
|2 DRIVER
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1465392652_32490
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
520 _ _ |a ObjectiveThis aims to evaluate the efficiency of three different powered interproximal enamel reduction (IER) systems and to assess enamel roughness before and after polishing using different polishing times.Material and methodsFour metal strips of the G5 ProLign Set (swissdentacare, SDC, Grancia, Switzerland), four segmental discs of the ASR-Set 4594 and two sonic tips of the SonicLine Set (both Gebr. Basseler GmbH & Co. KG, Komet, Lemgo, Germany) were evaluated. Human extracted incisors served as the medium. Enamel reduction was determined in five intervals of 15 s each. Polishing was performed for 15 and 30 s using the manufacturers’ recommended polishing systems. Enamel roughness (Ra) was quantitatively assessed by confocal laser scanning microscopy (CLSM).ResultsSignificant differences in terms of enamel reduction were found among the working ends of all tested systems. The time needed to remove 0.1, 0.2 and 0.3 mm of enamel was determined. Surface analysis showed significantly higher mean Ra values for nine out of ten working ends before polishing. This was still the case for five working ends after 15 s and for two after 30 s of polishing.ConclusionThe graining and the system used have a significant influence on enamel reduction. The time needed for polishing depends on the last working end used; a polishing time of 30 s is not always appropriate.Clinical relevanceKnowledge about the cutting efficiency of powered IER working ends might help the clinician to estimate better the amount of enamel reduction during the stripping process.
536 _ _ |a 899 - ohne Topic (POF3-899)
|0 G:(DE-HGF)POF3-899
|c POF3-899
|f POF III
|x 0
588 _ _ |a Dataset connected to CrossRef
700 1 _ |a Sommer, Andreas
|0 P:(DE-HGF)0
|b 1
700 1 _ |a Sen, Sinan
|0 P:(DE-HGF)0
|b 2
700 1 _ |a Saure, Daniel
|0 P:(DE-HGF)0
|b 3
700 1 _ |a Langer, Jochen
|0 P:(DE-HGF)0
|b 4
700 1 _ |a Guillon, Olivier
|0 P:(DE-Juel1)161591
|b 5
700 1 _ |a Lux, Christopher J.
|0 P:(DE-HGF)0
|b 6
773 _ _ |a 10.1007/s00784-015-1585-2
|0 PERI:(DE-600)1472578-2
|n 5
|p 933-942
|t Clinical oral investigations
|v 20
|y 2016
|x 1436-3771
856 4 _ |u https://juser.fz-juelich.de/record/807069/files/art_10.1007_s00784-015-1585-2.pdf
|y Restricted
856 4 _ |x icon
|u https://juser.fz-juelich.de/record/807069/files/art_10.1007_s00784-015-1585-2.gif?subformat=icon
|y Restricted
856 4 _ |x icon-1440
|u https://juser.fz-juelich.de/record/807069/files/art_10.1007_s00784-015-1585-2.jpg?subformat=icon-1440
|y Restricted
856 4 _ |x icon-180
|u https://juser.fz-juelich.de/record/807069/files/art_10.1007_s00784-015-1585-2.jpg?subformat=icon-180
|y Restricted
856 4 _ |x icon-640
|u https://juser.fz-juelich.de/record/807069/files/art_10.1007_s00784-015-1585-2.jpg?subformat=icon-640
|y Restricted
856 4 _ |x pdfa
|u https://juser.fz-juelich.de/record/807069/files/art_10.1007_s00784-015-1585-2.pdf?subformat=pdfa
|y Restricted
909 C O |o oai:juser.fz-juelich.de:807069
|p VDB
910 1 _ |a Forschungszentrum Jülich GmbH
|0 I:(DE-588b)5008462-8
|k FZJ
|b 5
|6 P:(DE-Juel1)161591
913 1 _ |a DE-HGF
|b Programmungebundene Forschung
|l ohne Programm
|1 G:(DE-HGF)POF3-890
|0 G:(DE-HGF)POF3-899
|2 G:(DE-HGF)POF3-800
|v ohne Topic
|x 0
|4 G:(DE-HGF)POF
|3 G:(DE-HGF)POF3
914 1 _ |y 2016
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
915 _ _ |a JCR
|0 StatID:(DE-HGF)0100
|2 StatID
|b CLIN ORAL INVEST : 2014
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0150
|2 StatID
|b Web of Science Core Collection
915 _ _ |a WoS
|0 StatID:(DE-HGF)0111
|2 StatID
|b Science Citation Index Expanded
915 _ _ |a IF < 5
|0 StatID:(DE-HGF)9900
|2 StatID
915 _ _ |a No Authors Fulltext
|0 StatID:(DE-HGF)0550
|2 StatID
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0310
|2 StatID
|b NCBI Molecular Biology Database
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0300
|2 StatID
|b Medline
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1110
|2 StatID
|b Current Contents - Clinical Medicine
915 _ _ |a Nationallizenz
|0 StatID:(DE-HGF)0420
|2 StatID
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0199
|2 StatID
|b Thomson Reuters Master Journal List
920 1 _ |0 I:(DE-Juel1)IEK-1-20101013
|k IEK-1
|l Werkstoffsynthese und Herstellungsverfahren
|x 0
920 1 _ |0 I:(DE-82)080011_20140620
|k JARA-ENERGY
|l JARA-ENERGY
|x 1
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a UNRESTRICTED
980 _ _ |a I:(DE-Juel1)IEK-1-20101013
980 _ _ |a I:(DE-82)080011_20140620
981 _ _ |a I:(DE-Juel1)IMD-2-20101013


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21