000808696 001__ 808696
000808696 005__ 20240711092304.0
000808696 0247_ $$2doi$$a10.1021/acs.energyfuels.5b02676
000808696 0247_ $$2WOS$$aWOS:000370679000021
000808696 037__ $$aFZJ-2016-02323
000808696 082__ $$a620
000808696 1001_ $$0P:(DE-Juel1)145872$$aBenito Abascal, Maria$$b0$$eCorresponding author$$ufzj
000808696 245__ $$aInfluence of Steam, Hydrogen Chloride and Hydrogen Sulphide on the Release and Condensation of Cadmium in Gasification
000808696 260__ $$aColumbus, Ohio$$bAmerican Chemical Society$$c2016
000808696 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1461132929_9235
000808696 3367_ $$2DataCite$$aOutput Types/Journal article
000808696 3367_ $$00$$2EndNote$$aJournal Article
000808696 3367_ $$2BibTeX$$aARTICLE
000808696 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000808696 3367_ $$2DRIVER$$aarticle
000808696 520__ $$aThe development of more efficient clean up techniques in coal power plants is essential in order to reduce trace metals emissions into the atmosphere. However, understanding of the behavior of the trace metals during the gasification process is necessary for the optimization of the hot gas cleaning systems. Thereby, in this work the influence of H2O, HCl, and H2S on the release and condensation behavior of Cd was experimentally investigated. The experiments were conducted in two different setups. The condensation behavior (temperature and speciation) of the trace metal vapors was investigated in a heated flow channel reactor housed in a furnace with a gas cooling zone. Experiments on the release of the inorganic vapors were carried out in a heated flow channel reactor coupled to a molecular beam mass spectrometer (MBMS) in order to analyze the gas in situ. The results of the experimental investigations were compared with Scheil–Gulliver cooling calculations performed by FactSage 6.3. Furthermore, thermodynamic pseudoequilibrium calculations were carried out to help in understanding the condensation mechanisms of the trace metal cadmium and the global kinetics in the experiments. The experimental results showed that the main chemical species detected in the condensation and release experiments were Cd, CdO, CdCl2, and CdS. In general, the speciation as well as the temperatures at which the species condensed and were present in the gas phase in the release experiments had the same trend in the calculations and in the experimental results. Thus, the Scheil–Gulliver cooling model was proved to be an excellent tool for the prediction of the release and condensation of cadmium. With this work, a better comprehension of the behavior of cadmium under gasification conditions was obtained.
000808696 536__ $$0G:(DE-HGF)POF3-111$$a111 - Efficient and Flexible Power Plants (POF3-111)$$cPOF3-111$$fPOF III$$x0
000808696 536__ $$0G:(DE-Juel1)HITEC-20170406$$aHITEC - Helmholtz Interdisciplinary Doctoral Training in Energy and Climate Research (HITEC) (HITEC-20170406)$$cHITEC-20170406$$x1
000808696 7001_ $$0P:(DE-Juel1)129688$$aBläsing, Marc$$b1
000808696 7001_ $$0P:(DE-HGF)0$$aNinomiya, Y.$$b2
000808696 7001_ $$0P:(DE-Juel1)129765$$aMüller, Michael$$b3
000808696 773__ $$0PERI:(DE-600)1483539-3$$a10.1021/acs.energyfuels.5b02676$$n2$$p943-953$$tEnergy & fuels$$v30$$x0887-0624$$y2016
000808696 8564_ $$uhttps://juser.fz-juelich.de/record/808696/files/acs.energyfuels.5b02676.pdf$$yRestricted
000808696 8564_ $$uhttps://juser.fz-juelich.de/record/808696/files/acs.energyfuels.5b02676.gif?subformat=icon$$xicon$$yRestricted
000808696 8564_ $$uhttps://juser.fz-juelich.de/record/808696/files/acs.energyfuels.5b02676.jpg?subformat=icon-1440$$xicon-1440$$yRestricted
000808696 8564_ $$uhttps://juser.fz-juelich.de/record/808696/files/acs.energyfuels.5b02676.jpg?subformat=icon-180$$xicon-180$$yRestricted
000808696 8564_ $$uhttps://juser.fz-juelich.de/record/808696/files/acs.energyfuels.5b02676.jpg?subformat=icon-640$$xicon-640$$yRestricted
000808696 8564_ $$uhttps://juser.fz-juelich.de/record/808696/files/acs.energyfuels.5b02676.pdf?subformat=pdfa$$xpdfa$$yRestricted
000808696 909CO $$ooai:juser.fz-juelich.de:808696$$pVDB
000808696 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)145872$$aForschungszentrum Jülich GmbH$$b0$$kFZJ
000808696 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129688$$aForschungszentrum Jülich GmbH$$b1$$kFZJ
000808696 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129765$$aForschungszentrum Jülich GmbH$$b3$$kFZJ
000808696 9131_ $$0G:(DE-HGF)POF3-111$$1G:(DE-HGF)POF3-110$$2G:(DE-HGF)POF3-100$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bEnergie$$lEnergieeffizienz, Materialien und Ressourcen$$vEfficient and Flexible Power Plants$$x0
000808696 9141_ $$y2016
000808696 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS
000808696 915__ $$0StatID:(DE-HGF)1160$$2StatID$$aDBCoverage$$bCurrent Contents - Engineering, Computing and Technology
000808696 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bENERG FUEL : 2014
000808696 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection
000808696 915__ $$0StatID:(DE-HGF)0110$$2StatID$$aWoS$$bScience Citation Index
000808696 915__ $$0StatID:(DE-HGF)0111$$2StatID$$aWoS$$bScience Citation Index Expanded
000808696 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5
000808696 915__ $$0StatID:(DE-HGF)0550$$2StatID$$aNo Authors Fulltext
000808696 915__ $$0StatID:(DE-HGF)0310$$2StatID$$aDBCoverage$$bNCBI Molecular Biology Database
000808696 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline
000808696 915__ $$0StatID:(DE-HGF)0420$$2StatID$$aNationallizenz
000808696 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bThomson Reuters Master Journal List
000808696 9201_ $$0I:(DE-Juel1)IEK-2-20101013$$kIEK-2$$lWerkstoffstruktur und -eigenschaften$$x0
000808696 980__ $$ajournal
000808696 980__ $$aVDB
000808696 980__ $$aUNRESTRICTED
000808696 980__ $$aI:(DE-Juel1)IEK-2-20101013
000808696 981__ $$aI:(DE-Juel1)IMD-1-20101013