% IMPORTANT: The following is UTF-8 encoded. This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.
@ARTICLE{Agostini:817756,
author = {Agostini, M. and Appel, S. and Bellini, G. and Benziger, J.
and Bick, D. and Bonfini, G. and Bravo, D. and Caccianiga,
B. and Calaprice, F. and Caminata, A. and Cavalcante, P. and
Chepurnov, A. and D’Angelo, D. and Davini, S. and Derbin,
A. and Di Noto, L. and Drachnev, I. and Empl, A. and Etenko,
A. and Fomenko, K. and Franco, D. and Gabriele, F. and
Galbiati, C. and Ghiano, C. and Giammarchi, M. and
Goeger-Neff, M. and Goretti, A. and Gromov, M. and Hagner,
C. and Hungerford, E. and Ianni, Aldo and Ianni, Andrea and
Jedrzejczak, K. and Kaiser, M. and Kobychev, V. and
Korablev, D. and Korga, G. and Kryn, D. and Laubenstein, M.
and Lehnert, B. and Litvinovich, E. and Lombardi, F. and
Lombardi, P. and Ludhova, L. and Lukyanchenko, G. and
Machulin, I. and Manecki, S. and Maneschg, W. and Marcocci,
S. and Meroni, E. and Meyer, M. and Miramonti, L. and
Misiaszek, M. and Montuschi, M. and Mosteiro, P. and
Muratova, V. and Neumair, B. and Oberauer, L. and Obolensky,
M. and Ortica, F. and Otis, K. and Pallavicini, M. and Papp,
L. and Perasso, L. and Pocar, A. and Ranucci, G. and Razeto,
A. and Re, A. and Romani, A. and Roncin, R. and Rossi, N.
and Schönert, S. and Semenov, D. and Simgen, H. and
Skorokhvatov, M. and Smirnov, O. and Sotnikov, A. and
Sukhotin, S. and Suvorov, Y. and Tartaglia, R. and Testera,
G. and Thurn, J. and Toropova, M. and Unzhakov, E. and
Vishneva, A. and Vogelaar, R. B. and von Feilitzsch, F. and
Wang, H. and Weinz, S. and Winter, J. and Wojcik, M. and
Wurm, M. and Yokley, Z. and Zaimidoroga, O. and Zavatarelli,
S. and Zuber, K. and Zuzel, G.},
title = {{T}est of {E}lectric {C}harge {C}onservation with
{B}orexino},
journal = {Physical review letters},
volume = {115},
number = {23},
issn = {1079-7114},
address = {College Park, Md.},
publisher = {APS},
reportid = {FZJ-2016-04399},
pages = {231802},
year = {2015},
abstract = {Borexino is a liquid scintillation detector located deep
underground at the Laboratori Nazionali del Gran Sasso
(LNGS, Italy). Thanks to the unmatched radio purity of the
scintillator, and to the well understood detector response
at low energy, a new limit on the stability of the electron
for decay into a neutrino and a single monoenergetic photon
was obtained. This new bound, τ≥6.6×1028 yr at
$90\%$ C.L., is 2 orders of magnitude better than the
previous limit.},
cin = {IKP-2},
ddc = {550},
cid = {I:(DE-Juel1)IKP-2-20111104},
pnm = {612 - Cosmic Matter in the Laboratory (POF3-612)},
pid = {G:(DE-HGF)POF3-612},
typ = {PUB:(DE-HGF)16},
UT = {WOS:000365881500001},
pubmed = {pmid:26684111},
doi = {10.1103/PhysRevLett.115.231802},
url = {https://juser.fz-juelich.de/record/817756},
}