001     818316
005     20210129224133.0
024 7 _ |a 10.1016/j.est.2015.12.006
|2 doi
024 7 _ |a WOS:000391140500031
|2 WOS
037 _ _ |a FZJ-2016-04788
082 _ _ |a 333.7
100 1 _ |a Stenzel, Peter
|0 P:(DE-Juel1)145405
|b 0
|e Corresponding author
245 _ _ |a Primary control provided by large-scale battery energy storage systems or fossil power plants in Germany and related environmental impacts
260 _ _ |a Amsterdam [u.a.]
|c 2016
|b Elsevier
336 7 _ |a article
|2 DRIVER
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1481550506_18982
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
520 _ _ |a Increasing renewable energy generation influences the reliability of electric power grids. Thus, there is a demand for new technical units providing ancillary services. Non-dispatchable renewable energy sources can be balanced by energy storage devices. By large-scale battery energy storage systems (BESSs) grid efficiency and reliability as well as power quality can be increased. A further characteristic of BESSs is the ability to respond rapidly and precisely to frequency deviations, making them technical ideal candidates for primary control provision (PCP).In this paper environmental impacts of PCP by novel Li-ion BESSs are compared to impacts of PCP by state-of-the-art coal power plants (CPPs) using a Life Cycle Assessment (LCA) approach and considering German control market conditions. The coal power plant stock is characterized by varying properties. Thus, different scenarios of CPP operation are analyzed by varying sensitive parameters like efficiency loss and required must-run capacity. Finally, PCP by BESSs and CPPs are compared in terms of environmental performance. The more must-run electricity generation is attributable to PCP of CPPs, the higher are the environmental impacts of these CPPs. This leads to a better relative environmental performance of BESSs in most scenarios. Contrary, comparative or even better environmental performance of CPPs compared to state-of-the-art BESSs can solely be achieved if power plants without load restrictions for provision of primary control and with extreme low efficiency losses caused by PCP are applied. Consequently, the results of this paper indicate that BESSs are a promising option to reduce environmental impacts of primary control provision.
536 _ _ |a 153 - Assessment of Energy Systems – Addressing Issues of Energy Efficiency and Energy Security (POF3-153)
|0 G:(DE-HGF)POF3-153
|c POF3-153
|f POF III
|x 0
588 _ _ |a Dataset connected to CrossRef
700 1 _ |a Koj, Jan Christian
|0 P:(DE-Juel1)158005
|b 1
|u fzj
700 1 _ |a Schreiber, Andrea
|0 P:(DE-Juel1)130483
|b 2
|u fzj
700 1 _ |a Hennings, Wilfried
|0 P:(DE-Juel1)130464
|b 3
|u fzj
700 1 _ |a Zapp, Petra
|0 P:(DE-Juel1)130493
|b 4
|u fzj
773 _ _ |a 10.1016/j.est.2015.12.006
|g p. S2352152X15300438
|0 PERI:(DE-600)2826805-2
|p 300-310
|t Journal of energy storage
|v 8
|y 2016
|x 2352-152X
856 4 _ |u https://juser.fz-juelich.de/record/818316/files/1-s2.0-S2352152X15300438-main.pdf
|y Restricted
856 4 _ |x icon
|u https://juser.fz-juelich.de/record/818316/files/1-s2.0-S2352152X15300438-main.gif?subformat=icon
|y Restricted
856 4 _ |x icon-1440
|u https://juser.fz-juelich.de/record/818316/files/1-s2.0-S2352152X15300438-main.jpg?subformat=icon-1440
|y Restricted
856 4 _ |x icon-180
|u https://juser.fz-juelich.de/record/818316/files/1-s2.0-S2352152X15300438-main.jpg?subformat=icon-180
|y Restricted
856 4 _ |x icon-640
|u https://juser.fz-juelich.de/record/818316/files/1-s2.0-S2352152X15300438-main.jpg?subformat=icon-640
|y Restricted
856 4 _ |x pdfa
|u https://juser.fz-juelich.de/record/818316/files/1-s2.0-S2352152X15300438-main.pdf?subformat=pdfa
|y Restricted
909 C O |o oai:juser.fz-juelich.de:818316
|p VDB
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 0
|6 P:(DE-Juel1)145405
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 1
|6 P:(DE-Juel1)158005
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 2
|6 P:(DE-Juel1)130483
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 3
|6 P:(DE-Juel1)130464
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 4
|6 P:(DE-Juel1)130493
913 1 _ |a DE-HGF
|l Technologie, Innovation und Gesellschaft
|1 G:(DE-HGF)POF3-150
|0 G:(DE-HGF)POF3-153
|2 G:(DE-HGF)POF3-100
|v Assessment of Energy Systems – Addressing Issues of Energy Efficiency and Energy Security
|x 0
|4 G:(DE-HGF)POF
|3 G:(DE-HGF)POF3
|b Energie
914 1 _ |y 2016
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
915 _ _ |a WoS
|0 StatID:(DE-HGF)0112
|2 StatID
|b Emerging Sources Citation Index
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0150
|2 StatID
|b Web of Science Core Collection
915 _ _ |a No Authors Fulltext
|0 StatID:(DE-HGF)0550
|2 StatID
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0199
|2 StatID
|b Thomson Reuters Master Journal List
920 _ _ |l yes
920 1 _ |0 I:(DE-Juel1)IEK-STE-20101013
|k IEK-STE
|l Systemforschung und Technologische Entwicklung
|x 0
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a UNRESTRICTED
980 _ _ |a I:(DE-Juel1)IEK-STE-20101013


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21