@ARTICLE{Weber:819881,
author = {Weber, Thomas and Bürger, Andreas and Dominiczak, Karsten
and Pintsuk, Gerald},
title = {{E}valuation of the cool-down behaviour of {ITER} {FW}
beryllium tiles for an early failure detection},
journal = {Nuclear materials and energy},
volume = {9},
issn = {2352-1791},
address = {Amsterdam [u.a.]},
publisher = {Elsevier},
reportid = {FZJ-2016-05457},
pages = {109–115},
year = {2016},
abstract = {The design of the first wall in ITER foresees several
hundred thousand beryllium tiles, which are bonded to the
water-cooled CuCrZr supporting structure. Due to the nature
of a Tokamak reactor this bonding is faced to thermal
fatigue. Since the failure of a single tile might already
have a major impact on the operability of ITER,
comprehensive high heat flux tests are performed on
prototypes prior to the acceptance of manufacturing
procedures. For a deeper understanding of the temperature
curves, which were and will be measured by IR devices of
these first wall prototypes, thermo-mechanical FEM
simulations shall demonstrate the possibilities of an early
bonding failure detection. Hereby, the maximum temperatures
for each cycle as well as the cool-down behaviour are the
input data.},
cin = {IEK-2 / IEK-4},
ddc = {333.7},
cid = {I:(DE-Juel1)IEK-2-20101013 / I:(DE-Juel1)IEK-4-20101013},
pnm = {174 - Plasma-Wall-Interaction (POF3-174)},
pid = {G:(DE-HGF)POF3-174},
typ = {PUB:(DE-HGF)16},
UT = {WOS:000391191500018},
doi = {10.1016/j.nme.2016.08.009},
url = {https://juser.fz-juelich.de/record/819881},
}