000821058 001__ 821058
000821058 005__ 20210129224736.0
000821058 020__ $$a978-1-4939-6401-7 (print)
000821058 020__ $$a978-1-4939-6403-1 (electronic)
000821058 0247_ $$2doi$$a10.1007/978-1-4939-6403-1_4
000821058 0247_ $$2ISSN$$a1064-3745
000821058 0247_ $$2ISSN$$a1940-6029
000821058 0247_ $$2WOS$$aWOS:000398304300005
000821058 037__ $$aFZJ-2016-06302
000821058 082__ $$a570
000821058 1001_ $$0P:(DE-HGF)0$$aSchmitt-Kopplin, Philippe$$b0$$eEditor
000821058 245__ $$aStatically Adsorbed Coatings for High Separation Efficiency and Resolution in CE–MS Peptide Analysis: Strategies and Implementation
000821058 260__ $$aNew York, NY$$bSpringer New York$$c2016
000821058 29510 $$aCapillary Electrophoresis / Schmitt-Kopplin, Philippe (Editor)   ; New York, NY : Springer New York, 2016, Chapter 4 ; ISSN: 1064-3745=1940-6029 ; ISBN: 978-1-4939-6401-7=978-1-4939-6403-1 ; doi:10.1007/978-1-4939-6403-1
000821058 300__ $$a53 - 75
000821058 3367_ $$2ORCID$$aBOOK_CHAPTER
000821058 3367_ $$07$$2EndNote$$aBook Section
000821058 3367_ $$2DRIVER$$abookPart
000821058 3367_ $$2BibTeX$$aINBOOK
000821058 3367_ $$2DataCite$$aOutput Types/Book chapter
000821058 3367_ $$0PUB:(DE-HGF)7$$2PUB:(DE-HGF)$$aContribution to a book$$bcontb$$mcontb$$s1479297825_29797
000821058 4900_ $$aMethods in Molecular Biology$$v1483
000821058 520__ $$aCoatings are necessary to prevent protein and peptide adsorption to the capillary surface and obtain high intermediate precision. In this protocol, we first present our basic strategy to address peptide separation using three different coatings: one neutral and two cationic coatings, the latter largely differing in their induced electroosmotic mobility. In detail, we will describe how we apply the statically adsorbed coatings to obtain very high plate numbers and high repeatability.With some model examples, we clearly describe the scope of the method for the analysis of peptide samples: tryptic digests are addressed as well as small glycoproteins and glycopeptides largely differing in their effective electrophoretic mobility. We also show that the method is suitable for a fast screening of peptide samples despite a high matrix load comprising of up to 500 mmol/L sodium chloride. We demonstrate that this basic CE-MS method is rather independent of the polarity of the analytes with a very fast near-baseline separation of very hydrophobic Aβ peptides related to the onset of Alzheimer's disease. These examples will give an impression, which coating is most suitable for a specific analytical application.Special attention is paid to difficult aspects of the coating procedure and the CE-MS method, e.g., the potential of cross-contamination when changing the coatings.
000821058 536__ $$0G:(DE-HGF)POF3-552$$a552 - Engineering Cell Function (POF3-552)$$cPOF3-552$$fPOF III$$x0
000821058 588__ $$aDataset connected to CrossRef Book Series
000821058 7001_ $$0P:(DE-Juel1)141687$$aPattky, Martin$$b1
000821058 7001_ $$0P:(DE-HGF)0$$aBarkovits, Katalin$$b2
000821058 7001_ $$0P:(DE-HGF)0$$aMarcus, Katrin$$b3
000821058 7001_ $$0P:(DE-Juel1)131988$$aWeiergräber, Oliver H.$$b4$$ufzj
000821058 7001_ $$0P:(DE-Juel1)138805$$aHuhn, Carolin$$b5$$eCorresponding author
000821058 773__ $$a10.1007/978-1-4939-6403-1_4
000821058 8564_ $$uhttps://juser.fz-juelich.de/record/821058/files/Statically%20Adsorbed%20Coatings%20for%20High%20Separation%20Efficiency%20and%20Resolution%20in%20CE%E2%80%93MS%20Peptide%20Analysis%3A%20Strategies%20and%20Implementation_2016%20.pdf$$yRestricted
000821058 8564_ $$uhttps://juser.fz-juelich.de/record/821058/files/Statically%20Adsorbed%20Coatings%20for%20High%20Separation%20Efficiency%20and%20Resolution%20in%20CE%E2%80%93MS%20Peptide%20Analysis%3A%20Strategies%20and%20Implementation_2016%20.pdf?subformat=pdfa$$xpdfa$$yRestricted
000821058 909CO $$ooai:juser.fz-juelich.de:821058$$pVDB
000821058 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)131988$$aForschungszentrum Jülich$$b4$$kFZJ
000821058 9131_ $$0G:(DE-HGF)POF3-552$$1G:(DE-HGF)POF3-550$$2G:(DE-HGF)POF3-500$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bKey Technologies$$lBioSoft – Fundamentals for future Technologies in the fields of Soft Matter and Life Sciences$$vEngineering Cell Function$$x0
000821058 9141_ $$y2016
000821058 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline
000821058 915__ $$0StatID:(DE-HGF)0310$$2StatID$$aDBCoverage$$bNCBI Molecular Biology Database
000821058 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS
000821058 920__ $$lyes
000821058 9201_ $$0I:(DE-Juel1)ICS-6-20110106$$kICS-6$$lStrukturbiochemie $$x0
000821058 980__ $$acontb
000821058 980__ $$aVDB
000821058 980__ $$aI:(DE-Juel1)ICS-6-20110106
000821058 980__ $$aUNRESTRICTED
000821058 981__ $$aI:(DE-Juel1)IBI-7-20200312