000824688 001__ 824688
000824688 005__ 20240711092256.0
000824688 0247_ $$2doi$$a10.1016/j.calphad.2016.03.004
000824688 0247_ $$2WOS$$aWOS:000377315100008
000824688 037__ $$aFZJ-2016-07246
000824688 082__ $$a540
000824688 1001_ $$0P:(DE-Juel1)156565$$aPillai, Rishi$$b0$$eCorresponding author
000824688 245__ $$aMethods to Increase Computtional Efficiency of CALPHAD-Based Thermodynamic and Kinetic Models Employed in Describing High Temperature Material Degradation
000824688 260__ $$aAmsterdam [u.a.]$$bElsevier Science$$c2016
000824688 3367_ $$2DRIVER$$aarticle
000824688 3367_ $$2DataCite$$aOutput Types/Journal article
000824688 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1481207879_21512
000824688 3367_ $$2BibTeX$$aARTICLE
000824688 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000824688 3367_ $$00$$2EndNote$$aJournal Article
000824688 520__ $$aCoupled thermodynamic and kinetic models rely on the thermodynamic and mobility databases which are compiled using critically assessed thermodynamic and diffusivity data acquired from various sources of experimental data. A continuous influx of experimental thermodynamic and kinetic data means that the respective databases have not only increased in complexity but also in size. The time and computational effort for the equilibrium calculations increases with increasing number of components and phases to be considered.In the present work, the applicability of a few methods was investigated to increase the computational efficiency of coupled thermodynamic and kinetic models. Three cases of varying complexities in terms of the number of phases, alloying elements and phenomena to be modelled were considered for demonstration. The distribution of the intensive thermodynamic calculations on multiple computing cores using MPI (Message Passing Interface) was undertaken. The interpolation scheme for dynamic storage of thermodynamic data available in the commercial software DICTRA was employed on a single computing core and the resulting performance was compared with the MPI computations. Additionally, the interpolation scheme was also parallelised to test its scaling capability in comparison to the computations performed solely with MPI.A linear scaling of computation speeds was observed with parallelisation of the thermodynamic calculations with MPI. However, the degree of scaling was dependent on the complexity of the calculation. The interpolation scheme on a single core in comparison with MPI on 48 cores was 20 times faster in one case but about 20–50 times slower in the other two cases. A parallelisation of the interpolation scheme improved its performance in the other two cases. However, the computational scaling was still poor compared to the MPI computations
000824688 536__ $$0G:(DE-HGF)POF3-111$$a111 - Efficient and Flexible Power Plants (POF3-111)$$cPOF3-111$$fPOF III$$x0
000824688 536__ $$0G:(DE-Juel1)HITEC-20170406$$aHITEC - Helmholtz Interdisciplinary Doctoral Training in Energy and Climate Research (HITEC) (HITEC-20170406)$$cHITEC-20170406$$x1
000824688 7001_ $$0P:(DE-Juel1)162507$$aGaliullin, Timur$$b1
000824688 7001_ $$0P:(DE-Juel1)129701$$aChyrkin, Anton$$b2
000824688 7001_ $$0P:(DE-Juel1)129782$$aQuadakkers, Willem J.$$b3
000824688 773__ $$0PERI:(DE-600)1501512-9$$a10.1016/j.calphad.2016.03.004$$p62-71$$tCalphad$$v53$$x0364-5916$$y2016
000824688 8564_ $$uhttps://juser.fz-juelich.de/record/824688/files/1-s2.0-S0364591616300244-main.pdf$$yRestricted
000824688 8564_ $$uhttps://juser.fz-juelich.de/record/824688/files/1-s2.0-S0364591616300244-main.gif?subformat=icon$$xicon$$yRestricted
000824688 8564_ $$uhttps://juser.fz-juelich.de/record/824688/files/1-s2.0-S0364591616300244-main.jpg?subformat=icon-1440$$xicon-1440$$yRestricted
000824688 8564_ $$uhttps://juser.fz-juelich.de/record/824688/files/1-s2.0-S0364591616300244-main.jpg?subformat=icon-180$$xicon-180$$yRestricted
000824688 8564_ $$uhttps://juser.fz-juelich.de/record/824688/files/1-s2.0-S0364591616300244-main.jpg?subformat=icon-640$$xicon-640$$yRestricted
000824688 8564_ $$uhttps://juser.fz-juelich.de/record/824688/files/1-s2.0-S0364591616300244-main.pdf?subformat=pdfa$$xpdfa$$yRestricted
000824688 909CO $$ooai:juser.fz-juelich.de:824688$$pVDB
000824688 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)156565$$aForschungszentrum Jülich$$b0$$kFZJ
000824688 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)162507$$aForschungszentrum Jülich$$b1$$kFZJ
000824688 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129701$$aForschungszentrum Jülich$$b2$$kFZJ
000824688 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129782$$aForschungszentrum Jülich$$b3$$kFZJ
000824688 9131_ $$0G:(DE-HGF)POF3-111$$1G:(DE-HGF)POF3-110$$2G:(DE-HGF)POF3-100$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bEnergie$$lEnergieeffizienz, Materialien und Ressourcen$$vEfficient and Flexible Power Plants$$x0
000824688 9141_ $$y2016
000824688 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS
000824688 915__ $$0StatID:(DE-HGF)1160$$2StatID$$aDBCoverage$$bCurrent Contents - Engineering, Computing and Technology
000824688 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search
000824688 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bCALPHAD : 2015
000824688 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection
000824688 915__ $$0StatID:(DE-HGF)0110$$2StatID$$aWoS$$bScience Citation Index
000824688 915__ $$0StatID:(DE-HGF)0111$$2StatID$$aWoS$$bScience Citation Index Expanded
000824688 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5
000824688 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC
000824688 915__ $$0StatID:(DE-HGF)1150$$2StatID$$aDBCoverage$$bCurrent Contents - Physical, Chemical and Earth Sciences
000824688 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline
000824688 915__ $$0StatID:(DE-HGF)0550$$2StatID$$aNo Authors Fulltext
000824688 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bThomson Reuters Master Journal List
000824688 9201_ $$0I:(DE-Juel1)IEK-2-20101013$$kIEK-2$$lWerkstoffstruktur und -eigenschaften$$x0
000824688 980__ $$ajournal
000824688 980__ $$aVDB
000824688 980__ $$aUNRESTRICTED
000824688 980__ $$aI:(DE-Juel1)IEK-2-20101013
000824688 981__ $$aI:(DE-Juel1)IMD-1-20101013