001     825324
005     20240619091224.0
024 7 _ |a 10.1088/2057-1976/2/5/05517
|2 doi
024 7 _ |a 2128/15762
|2 Handle
037 _ _ |a FZJ-2016-07787
082 _ _ |a 610
100 1 _ |a Maybeck, Vanessa
|0 P:(DE-Juel1)128705
|b 0
|u fzj
245 _ _ |a An evaluation of extracellular MEA versus optogenetic stimulation of cortical neurons
260 _ _ |a Bristol
|c 2016
|b IOP Publ.
336 7 _ |a article
|2 DRIVER
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1509978372_25965
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
520 _ _ |a Objective. The importance of extracellular neural stimulation has driven the development of multiple technologies. Of growing importance is accurately stimulating single neurons in dense networks. It is unlikely that one approach is best for all applications, however comparisons between methods are lacking. We aim to show the strengths and suitable applications for two tools; micro-electrode array (MEA) stimulation and optogenetics. Approach. We compare MEA-based electrical stimulation to Channelrhodopsin 2 based optogenetic stimulation of dissociated cortical neurons in vitro. Effectivity is compared based on stimulation success rate, spatial and temporal accuracy, and reproducibility. We discuss how necessities of each method may limit performance in each category. Main Results. MEA stimulation outperformed optogenetic stimulation in the speed with which an action potential could be generated. The relation between the size of the stimulating point (electrode or illumination spot) and the area of stimulated tissue was similar in both methods. However, technical difficulties in maintaining low impedance from very small electrodes allows higher spatial specificity in optogenetic stimulation. If simultaneous recording and stimulation are desired, MEA stimulation artifacts were far more impairing than light induce artifacts on MEA recordings. Significance. The like versus like comparison of stimulation technologies provides an incomplete evaluation tool for researchers desiring to apply these technologies. This comparison highlights advantages for specific applications and should promote more cross-topic evaluations.
536 _ _ |a 552 - Engineering Cell Function (POF3-552)
|0 G:(DE-HGF)POF3-552
|c POF3-552
|f POF III
|x 0
700 1 _ |a Schnitker, Jan
|0 P:(DE-Juel1)140152
|b 1
|u fzj
700 1 _ |a Li, Wenfang
|0 P:(DE-Juel1)157679
|b 2
|u fzj
700 1 _ |a Heuschkel, M.
|0 P:(DE-HGF)0
|b 3
700 1 _ |a Offenhäusser, Andreas
|0 P:(DE-Juel1)128713
|b 4
|e Corresponding author
|u fzj
773 _ _ |a 10.1088/2057-1976/2/5/05517
|0 PERI:(DE-600)2844309-3
|n 5
|p 055017
|t Biomedical physics & engineering express
|v 2
|y 2016
|x 2057-1976
856 4 _ |u https://juser.fz-juelich.de/record/825324/files/Maybeck_2016_Biomed._Phys._Eng._Express_2_055017.pdf
|y Restricted
856 4 _ |y OpenAccess
|u https://juser.fz-juelich.de/record/825324/files/Maybeck_2016_BPEX.pdf
856 4 _ |x pdfa
|u https://juser.fz-juelich.de/record/825324/files/Maybeck_2016_Biomed._Phys._Eng._Express_2_055017.pdf?subformat=pdfa
|y Restricted
856 4 _ |y OpenAccess
|x icon
|u https://juser.fz-juelich.de/record/825324/files/Maybeck_2016_BPEX.gif?subformat=icon
856 4 _ |y OpenAccess
|x icon-1440
|u https://juser.fz-juelich.de/record/825324/files/Maybeck_2016_BPEX.jpg?subformat=icon-1440
856 4 _ |y OpenAccess
|x icon-180
|u https://juser.fz-juelich.de/record/825324/files/Maybeck_2016_BPEX.jpg?subformat=icon-180
856 4 _ |y OpenAccess
|x icon-640
|u https://juser.fz-juelich.de/record/825324/files/Maybeck_2016_BPEX.jpg?subformat=icon-640
856 4 _ |y OpenAccess
|x pdfa
|u https://juser.fz-juelich.de/record/825324/files/Maybeck_2016_BPEX.pdf?subformat=pdfa
909 C O |o oai:juser.fz-juelich.de:825324
|p openaire
|p open_access
|p driver
|p VDB
|p dnbdelivery
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 0
|6 P:(DE-Juel1)128705
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 1
|6 P:(DE-Juel1)140152
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 2
|6 P:(DE-Juel1)157679
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 4
|6 P:(DE-Juel1)128713
913 1 _ |a DE-HGF
|b Key Technologies
|l BioSoft – Fundamentals for future Technologies in the fields of Soft Matter and Life Sciences
|1 G:(DE-HGF)POF3-550
|0 G:(DE-HGF)POF3-552
|2 G:(DE-HGF)POF3-500
|v Engineering Cell Function
|x 0
|4 G:(DE-HGF)POF
|3 G:(DE-HGF)POF3
914 1 _ |y 2016
915 _ _ |a OpenAccess
|0 StatID:(DE-HGF)0510
|2 StatID
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0300
|2 StatID
|b Medline
920 _ _ |l yes
920 1 _ |0 I:(DE-Juel1)ICS-8-20110106
|k ICS-8
|l Bioelektronik
|x 0
980 1 _ |a FullTexts
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a UNRESTRICTED
980 _ _ |a I:(DE-Juel1)ICS-8-20110106
981 _ _ |a I:(DE-Juel1)IBI-3-20200312


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21