% IMPORTANT: The following is UTF-8 encoded.  This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.

@ARTICLE{SyedMohd:825739,
      author       = {Syed Mohd, A. and Pütter, S. and Mattauch, S. and
                      Koutsioumpas, Alexandros and Schneider, Harald and Weber,
                      Alexander and Brückel, T.},
      title        = {{A} versatile {UHV} transport and measurement chamber for
                      neutron reflectometry under {UHV} conditions},
      journal      = {Review of scientific instruments},
      volume       = {87},
      number       = {12},
      issn         = {1089-7623},
      address      = {[S.l.]},
      publisher    = {American Institute of Physics},
      reportid     = {FZJ-2017-00051},
      pages        = {123909 -},
      year         = {2016},
      abstract     = {We report on a versatile mini ultra-high vacuum (UHV)
                      chamber which is designed to be used on the MAgnetic
                      Reflectometer with high Incident Angle of the Jülich Centre
                      for Neutron Science at Heinz Maier-Leibnitz Zentrum in
                      Garching, Germany. Samples are prepared in the adjacent thin
                      film laboratory by molecular beam epitaxy and moved into the
                      compact chamber for transfer without exposure to ambient
                      air. The chamber is based on DN 40 CF flanges and equipped
                      with sapphire view ports, a small getter pump, and a wobble
                      stick, which serves also as sample holder. Here, we present
                      polarized neutron reflectivity measurements which have been
                      performed on Co thin films at room temperature in UHV and in
                      ambient air in a magnetic field of 200 mT and in the Q-range
                      of 0.18 Å−1. The results confirm that the Co film is not
                      contaminated during the polarized neutron reflectivity
                      measurement. Herewith it is demonstrated that the mini UHV
                      transport chamber also works as a measurement chamber which
                      opens new possibilities for polarized neutron measurements
                      under UHV conditions.},
      cin          = {JCNS-FRM-II / JCNS-2 / PGI-4 / JARA-FIT},
      ddc          = {530},
      cid          = {I:(DE-Juel1)JCNS-FRM-II-20110218 /
                      I:(DE-Juel1)JCNS-2-20110106 / I:(DE-Juel1)PGI-4-20110106 /
                      $I:(DE-82)080009_20140620$},
      pnm          = {524 - Controlling Collective States (POF3-524) / 6212 -
                      Quantum Condensed Matter: Magnetism, Superconductivity
                      (POF3-621) / 6G15 - FRM II / MLZ (POF3-6G15) / 6G4 - Jülich
                      Centre for Neutron Research (JCNS) (POF3-623) / NFFA-Europe
                      - NANOSCIENCE FOUNDRIES AND FINE ANALYSIS - EUROPE (654360)},
      pid          = {G:(DE-HGF)POF3-524 / G:(DE-HGF)POF3-6212 /
                      G:(DE-HGF)POF3-6G15 / G:(DE-HGF)POF3-6G4 /
                      G:(EU-Grant)654360},
      experiment   = {EXP:(DE-MLZ)MARIA-20140101 / EXP:(DE-MLZ)MBE-MLZ-20151210},
      typ          = {PUB:(DE-HGF)16},
      UT           = {WOS:000392096800038},
      pubmed       = {pmid:28040933},
      doi          = {10.1063/1.4972993},
      url          = {https://juser.fz-juelich.de/record/825739},
}