000827062 1001_ $$0P:(DE-Juel1)133944$$aStreun, M.$$b0$$eCorresponding author
000827062 1112_ $$aIEEE Medical Imaging Conference 2016$$cStrasbourg$$d2016-10-31 - 2016-11-05$$gMIC 2016$$wFrance
000827062 245__ $$aphenoPET – Results from the Plant Scanner
000827062 260__ $$c2016
000827062 3367_ $$033$$2EndNote$$aConference Paper
000827062 3367_ $$2DataCite$$aOther
000827062 3367_ $$2BibTeX$$aINPROCEEDINGS
000827062 3367_ $$2DRIVER$$aconferenceObject
000827062 3367_ $$2ORCID$$aLECTURE_SPEECH
000827062 3367_ $$0PUB:(DE-HGF)6$$2PUB:(DE-HGF)$$aConference Presentation$$bconf$$mconf$$s1485958614_20953$$xAfter Call
000827062 520__ $$aWithin the German Plant Phenotyping Network (DPPN), we developed a novel PET scanner based on Philips Digital Photon Counters (DPCs, or dSiPMs = digital Silicon Photomultipliers). The scanner is dedicated for plant research and provides functional information on carbon transport within the plant. To this end the detector ring is oriented horizontally.  It provides a Field-of-View of 18 cm dia. and 20 cm in height. The read-out electronics cluster hits from different photodetector pixels when they originate from the same scintillation event. These single events are written via USB 3.0 with up to 300 MB/s to the computer system. Crystal identification, energy discrimination and coincidence detection is realized in software. The spatial resolution in the center Field-of-View (CFOV) could be estimated to approx. 1.6 mm from measurements of a dedicated hot rod phantom. Preliminary sensitivity measurements result in a peak sensitivity of 4.04% (ΔE = 250-750 keV) in the CFOV and a Coincidence Resolving Time of 298 ps could be achieved.
000827062 536__ $$0G:(DE-HGF)POF3-582$$a582 - Plant Science (POF3-582)$$cPOF3-582$$fPOF III$$x0
000827062 536__ $$0G:(DE-Juel1)BMBF-031A053A$$aDPPN - Deutsches Pflanzen Phänotypisierungsnetzwerk (BMBF-031A053A)$$cBMBF-031A053A$$fDeutsches Pflanzen Phänotypisierungsnetzwerk$$x1
000827062 7001_ $$0P:(DE-Juel1)131784$$aPflugfelder, D.$$b1
000827062 7001_ $$0P:(DE-Juel1)130632$$aErven, A.$$b2
000827062 7001_ $$0P:(DE-Juel1)156472$$aJokhovets, L.$$b3
000827062 7001_ $$0P:(DE-Juel1)129360$$aMetzner, R.$$b4
000827062 7001_ $$0P:(DE-Juel1)133922$$aNöldgen, H.$$b5
000827062 7001_ $$0P:(DE-Juel1)131791$$aScheins, J.$$b6
000827062 7001_ $$0P:(DE-Juel1)129303$$aChlubek, A.$$b7
000827062 7001_ $$0P:(DE-Juel1)129336$$aJahnke, S.$$b8
000827062 7001_ $$0P:(DE-Juel1)142562$$avan Waasen, Stefan$$b9
000827062 7001_ $$0P:(DE-Juel1)129402$$aSchurr, U.$$b10
000827062 7001_ $$0P:(DE-Juel1)142421$$aBorggrewe, Kerstin$$b11$$ufzj
000827062 7001_ $$0P:(DE-Juel1)129307$$aDautzenberg, Marco$$b12$$ufzj
000827062 7001_ $$0P:(DE-Juel1)167475$$aDegenhardt, Carsten$$b13$$ufzj
000827062 7001_ $$0P:(DE-HGF)0$$aDorscheid, Ralf$$b14
000827062 7001_ $$0P:(DE-Juel1)161528$$aDurini, Daniel$$b15$$ufzj
000827062 7001_ $$0P:(DE-HGF)0$$aMeessen, Louis$$b16
000827062 7001_ $$0P:(DE-HGF)0$$aMülhens, Oliver$$b17
000827062 7001_ $$0P:(DE-HGF)0$$aReinartz, Sebastian$$b18
000827062 7001_ $$0P:(DE-HGF)0$$aZwaans, Ben$$b19
000827062 909CO $$ooai:juser.fz-juelich.de:827062$$pVDB
000827062 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)133944$$aForschungszentrum Jülich$$b0$$kFZJ
000827062 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)131784$$aForschungszentrum Jülich$$b1$$kFZJ
000827062 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)130632$$aForschungszentrum Jülich$$b2$$kFZJ
000827062 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)156472$$aForschungszentrum Jülich$$b3$$kFZJ
000827062 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129360$$aForschungszentrum Jülich$$b4$$kFZJ
000827062 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)133922$$aForschungszentrum Jülich$$b5$$kFZJ
000827062 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)131791$$aForschungszentrum Jülich$$b6$$kFZJ
000827062 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129303$$aForschungszentrum Jülich$$b7$$kFZJ
000827062 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129336$$aForschungszentrum Jülich$$b8$$kFZJ
000827062 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)142562$$aForschungszentrum Jülich$$b9$$kFZJ
000827062 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129402$$aForschungszentrum Jülich$$b10$$kFZJ
000827062 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)142421$$aForschungszentrum Jülich$$b11$$kFZJ
000827062 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129307$$aForschungszentrum Jülich$$b12$$kFZJ
000827062 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)167475$$aForschungszentrum Jülich$$b13$$kFZJ
000827062 9101_ $$0I:(DE-HGF)0$$6P:(DE-HGF)0$$aExternal Institute$$b14$$kExtern
000827062 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)161528$$aForschungszentrum Jülich$$b15$$kFZJ
000827062 9131_ $$0G:(DE-HGF)POF3-582$$1G:(DE-HGF)POF3-580$$2G:(DE-HGF)POF3-500$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bKey Technologies$$lKey Technologies for the Bioeconomy$$vPlant Science$$x0
000827062 9141_ $$y2016
000827062 915__ $$0StatID:(DE-HGF)0550$$2StatID$$aNo Authors Fulltext
000827062 9201_ $$0I:(DE-Juel1)ZEA-2-20090406$$kZEA-2$$lZentralinstitut für Elektronik$$x0
000827062 9201_ $$0I:(DE-Juel1)IBG-2-3-TA-20110204$$kIBG-2-3-TA$$lBiotechnologie Technische und administrative Infrastruktur IBG-2 und 3$$x1
000827062 980__ $$aconf
000827062 980__ $$aVDB
000827062 980__ $$aUNRESTRICTED
000827062 980__ $$aI:(DE-Juel1)ZEA-2-20090406
000827062 980__ $$aI:(DE-Juel1)IBG-2-3-TA-20110204
000827062 981__ $$aI:(DE-Juel1)PGI-4-20110106