000827071 001__ 827071
000827071 005__ 20250129092512.0
000827071 037__ $$aFZJ-2017-01277
000827071 041__ $$aEnglish
000827071 1001_ $$0P:(DE-Juel1)133944$$aStreun, M.$$b0
000827071 1112_ $$aIEEE Medical Imaging Conference 2015$$cSan Diego$$d2015-10-31 - 2015-11-07$$gMIC 2015$$wUSA
000827071 245__ $$aFirst Evaluation of phenoPET
000827071 260__ $$c2016
000827071 3367_ $$033$$2EndNote$$aConference Paper
000827071 3367_ $$2BibTeX$$aINPROCEEDINGS
000827071 3367_ $$2DRIVER$$aconferenceObject
000827071 3367_ $$2ORCID$$aCONFERENCE_POSTER
000827071 3367_ $$2DataCite$$aOutput Types/Conference Poster
000827071 3367_ $$0PUB:(DE-HGF)24$$2PUB:(DE-HGF)$$aPoster$$bposter$$mposter$$s1485958699_20946$$xAfter Call
000827071 500__ $$aThe phenoPET system is a PET scanner dedicated for plant research. It was developed and is being established at the Research Center in Jülich. The scanner employs LuYAP scintillators of 1.85×1.85×10 mm3 and digital SiPM arrays as photo detectors (DPC3200-22-44, Philips Digital Photon Counting) which are arranged in three stacked rings. The field of view measures 18 cm in diameter and 20 cm of axial height. The electronic hardware allows coincidence detection in realtime performed on a Kintex-7 FPGA (Xilinx). The system was introduced in 2014 [1] but at this time consisted of a single detector ring only. Now we will present results obtained from measurements with the complete scanner. [1] M. Streun et al.,  “phenoPET: A dedicated PET Scanner for Plant Research based on digital SiPMs (DPCs)”, NSS/MIC 2014, Seattle, Conf. Rec. M11-18 (2014)
000827071 536__ $$0G:(DE-HGF)POF3-582$$a582 - Plant Science (POF3-582)$$cPOF3-582$$fPOF III$$x0
000827071 536__ $$0G:(DE-Juel1)BMBF-031A053A$$aDPPN - Deutsches Pflanzen Phänotypisierungsnetzwerk (BMBF-031A053A)$$cBMBF-031A053A$$fDeutsches Pflanzen Phänotypisierungsnetzwerk$$x1
000827071 7001_ $$0P:(DE-Juel1)130632$$aErven, A.$$b1
000827071 7001_ $$0P:(DE-Juel1)156472$$aJokhovets, L.$$b2
000827071 7001_ $$0P:(DE-Juel1)133922$$aNöldgen, H.$$b3
000827071 7001_ $$0P:(DE-Juel1)131791$$aScheins, J.$$b4
000827071 7001_ $$0P:(DE-Juel1)129336$$aJahnke, S.$$b5
000827071 7001_ $$0P:(DE-Juel1)142562$$avan Waasen, Stefan$$b6
000827071 7001_ $$0P:(DE-Juel1)129402$$aSchurr, U.$$b7
000827071 7001_ $$0P:(DE-Juel1)167475$$aDegenhardt, Carsten$$b8
000827071 7001_ $$0P:(DE-HGF)0$$aDorscheid, Ralf$$b9
000827071 7001_ $$0P:(DE-HGF)0$$aMeessen, Louis$$b10
000827071 7001_ $$0P:(DE-HGF)0$$aMülhens, Oliver$$b11
000827071 7001_ $$0P:(DE-HGF)0$$aReinartz, Sebastian$$b12
000827071 7001_ $$0P:(DE-HGF)0$$aZwaans, Ben$$b13
000827071 7001_ $$0P:(DE-Juel1)133864$$aBeer, Simone$$b14$$ufzj
000827071 7001_ $$0P:(DE-Juel1)133648$$aDaemen, Jos$$b15$$ufzj
000827071 7001_ $$0P:(DE-Juel1)140423$$aFried, Eduard$$b16
000827071 7001_ $$0P:(DE-HGF)0$$aHämisch, York$$b17
000827071 7001_ $$0P:(DE-Juel1)133720$$aPap, Mihaly$$b18$$ufzj
000827071 7001_ $$0P:(DE-Juel1)133938$$aSchramm, Nils$$b19$$ufzj
000827071 7001_ $$0P:(DE-Juel1)133902$$aKemmerling, Günter$$b20$$ufzj
000827071 909CO $$ooai:juser.fz-juelich.de:827071$$pVDB
000827071 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)133944$$aForschungszentrum Jülich$$b0$$kFZJ
000827071 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)130632$$aForschungszentrum Jülich$$b1$$kFZJ
000827071 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)156472$$aForschungszentrum Jülich$$b2$$kFZJ
000827071 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)133922$$aForschungszentrum Jülich$$b3$$kFZJ
000827071 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)131791$$aForschungszentrum Jülich$$b4$$kFZJ
000827071 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129336$$aForschungszentrum Jülich$$b5$$kFZJ
000827071 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)142562$$aForschungszentrum Jülich$$b6$$kFZJ
000827071 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129402$$aForschungszentrum Jülich$$b7$$kFZJ
000827071 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)167475$$aForschungszentrum Jülich$$b8$$kFZJ
000827071 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)133864$$aForschungszentrum Jülich$$b14$$kFZJ
000827071 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)133648$$aForschungszentrum Jülich$$b15$$kFZJ
000827071 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)133720$$aForschungszentrum Jülich$$b18$$kFZJ
000827071 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)133938$$aForschungszentrum Jülich$$b19$$kFZJ
000827071 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)133902$$aForschungszentrum Jülich$$b20$$kFZJ
000827071 9131_ $$0G:(DE-HGF)POF3-582$$1G:(DE-HGF)POF3-580$$2G:(DE-HGF)POF3-500$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bKey Technologies$$lKey Technologies for the Bioeconomy$$vPlant Science$$x0
000827071 9141_ $$y2016
000827071 915__ $$0StatID:(DE-HGF)0550$$2StatID$$aNo Authors Fulltext
000827071 9201_ $$0I:(DE-Juel1)ZEA-2-20090406$$kZEA-2$$lZentralinstitut für Elektronik$$x0
000827071 9201_ $$0I:(DE-Juel1)IBG-2-3-TA-20110204$$kIBG-2-3-TA$$lBiotechnologie Technische und administrative Infrastruktur IBG-2 und 3$$x1
000827071 980__ $$aposter
000827071 980__ $$aVDB
000827071 980__ $$aUNRESTRICTED
000827071 980__ $$aI:(DE-Juel1)ZEA-2-20090406
000827071 980__ $$aI:(DE-Juel1)IBG-2-3-TA-20110204
000827071 981__ $$aI:(DE-Juel1)PGI-4-20110106