001     827181
005     20240610120415.0
024 7 _ |2 doi
|a 10.1002/9783527808465.EMC2016.6971
037 _ _ |a FZJ-2017-01379
041 _ _ |a English
100 1 _ |0 P:(DE-HGF)0
|a Chang, Shery
|b 0
|e Corresponding author
111 2 _ |a 16th European Microscopy Congress (EMC 2016)
|c Lyon
|d 2016-08-28 - 2016-09-02
|w France
245 _ _ |a Low dose electron holography using direct-electron detection camera
260 _ _ |a Weinheim, Germany
|b Wiley-VCH Verlag GmbH & Co. KGaA
|c 2016
295 1 0 |a European Microscopy Congress 2016: Proceedings
300 _ _ |a 769 - 770
336 7 _ |2 ORCID
|a CONFERENCE_PAPER
336 7 _ |0 33
|2 EndNote
|a Conference Paper
336 7 _ |2 BibTeX
|a INPROCEEDINGS
336 7 _ |2 DRIVER
|a conferenceObject
336 7 _ |2 DataCite
|a Output Types/Conference Paper
336 7 _ |0 PUB:(DE-HGF)8
|2 PUB:(DE-HGF)
|a Contribution to a conference proceedings
|b contrib
|m contrib
|s 1485873131_18213
336 7 _ |0 PUB:(DE-HGF)7
|2 PUB:(DE-HGF)
|a Contribution to a book
|m contb
520 _ _ |a The advent of commercially-available direct detection cameras (DDCs) for transmission electron microscopy (TEM) offers the opportunity to reduce noise in images and diffraction patterns as well as providing fast frame rates for image recording. For sufficiently low dose rates, their design can enable significant improvements in detective quantum efficiency (DQE) and modulation transfer function (MTF) when compared to conventional charge-coupled device (CCD) cameras. Existing literature on DDCs is focused predominantly on structural biological applications, where they provide clear advantages under low dose conditions, e.g., typically < 10 e−Å−2 . Whereas the characteristics of DDCs at dose rates and spatial resolutions that are applicable to biological materials are already well established, in many other areas of TEM the dose rate can exceed 1000 e−Å−2, while the spatial resolution can vary from nanometers to better than 1 Å. In these contexts, the benefit of DDCs is less clear.Here, we examine this question in the context of high-resolution phase contrast imaging and off-axis electron holography and demonstrate that the improved MTF and DQE of a DDC result in clear benefits over conventional CCD cameras. For electron holography, we find a significant improvement in the holographic interference fringe visibility and a reduction in statistical error in the phase of the reconstructed electron wavefunction. In addition, we show that at least three-fold improvement in optimum phase resolution using the counting mode provided by DDC with four time less dose rate compared that of a conventional CCD camera (with a fringe spacing of 83pm in this case). Further improvement in SNR could be obtained by correlation and averaging over a series of holograms. As a result of the low camera noise, the correlation of individual hologram is robust even at low dose rates, and the averaging leads to an improvement in SNR that is close to the ideal root-N behavior (N being the number of images).Using BiFeO3 on DyScO3 substrate as an example, we demonstrate that both specimen and birpism fringe drift can be successfully correlated over 100 frames of hologram (total exposure of 20 sec at a dose rate of 10 e− per pixel per sec), as shown in Fig. 2. Our results show that DDCs are highly beneficial for electron holography (and similarly to high-resolution TEM ) at low dose rates, thereby minimising potential specimen damage while maintaining an adequate SNR for analysis.
536 _ _ |0 G:(DE-HGF)POF3-143
|a 143 - Controlling Configuration-Based Phenomena (POF3-143)
|c POF3-143
|f POF III
|x 0
588 _ _ |a Dataset connected to CrossRef Book
700 1 _ |0 P:(DE-Juel1)145711
|a Jin, Lei
|b 1
700 1 _ |0 P:(DE-Juel1)130525
|a Barthel, Juri
|b 2
700 1 _ |0 P:(DE-Juel1)144121
|a Dunin-Borkowski, Rafal
|b 3
700 1 _ |0 P:(DE-Juel1)159157
|a Dwyer, Christian
|b 4
773 _ _ |a 10.1002/9783527808465.EMC2016.6971
856 4 _ |u https://juser.fz-juelich.de/record/827181/files/emc20166971.pdf
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/827181/files/emc20166971.gif?subformat=icon
|x icon
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/827181/files/emc20166971.jpg?subformat=icon-1440
|x icon-1440
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/827181/files/emc20166971.jpg?subformat=icon-180
|x icon-180
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/827181/files/emc20166971.jpg?subformat=icon-640
|x icon-640
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/827181/files/emc20166971.pdf?subformat=pdfa
|x pdfa
|y Restricted
909 C O |o oai:juser.fz-juelich.de:827181
|p VDB
910 1 _ |0 I:(DE-588b)5008462-8
|6 P:(DE-Juel1)145711
|a Forschungszentrum Jülich
|b 1
|k FZJ
910 1 _ |0 I:(DE-588b)5008462-8
|6 P:(DE-Juel1)130525
|a Forschungszentrum Jülich
|b 2
|k FZJ
910 1 _ |0 I:(DE-588b)5008462-8
|6 P:(DE-Juel1)144121
|a Forschungszentrum Jülich
|b 3
|k FZJ
913 1 _ |0 G:(DE-HGF)POF3-143
|1 G:(DE-HGF)POF3-140
|2 G:(DE-HGF)POF3-100
|a DE-HGF
|l Future Information Technology - Fundamentals, Novel Concepts and Energy Efficiency (FIT)
|v Controlling Configuration-Based Phenomena
|x 0
|4 G:(DE-HGF)POF
|3 G:(DE-HGF)POF3
|b Energie
914 1 _ |y 2016
920 _ _ |l yes
920 1 _ |0 I:(DE-Juel1)PGI-5-20110106
|k PGI-5
|l Mikrostrukturforschung
|x 0
920 1 _ |0 I:(DE-Juel1)ER-C-1-20170209
|k ER-C-1
|l Physik Nanoskaliger Systeme
|x 1
980 _ _ |a contrib
980 _ _ |a VDB
980 _ _ |a contb
980 _ _ |a I:(DE-Juel1)PGI-5-20110106
980 _ _ |a I:(DE-Juel1)ER-C-1-20170209
980 _ _ |a UNRESTRICTED
981 _ _ |a I:(DE-Juel1)ER-C-1-20170209


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21