000827199 001__ 827199
000827199 005__ 20240610120545.0
000827199 0247_ $$2doi$$a10.1002/9783527808465.EMC2016.6191
000827199 037__ $$aFZJ-2017-01397
000827199 041__ $$aEnglish
000827199 1001_ $$0P:(DE-Juel1)159136$$aMigunov, Vadim$$b0$$eCorresponding author
000827199 1112_ $$a16th European Microscopy Congress (EMC 2016)$$cLyon$$d2016-08-28 - 2016-09-02$$wFrance
000827199 245__ $$aElectron tomography with sub-5-second temporal resolution for dynamic in situ transmission electron microscopy
000827199 260__ $$aWeinheim, Germany$$bWiley-VCH Verlag GmbH & Co. KGaA$$c2016
000827199 29510 $$aEuropean Microscopy Congress 2016: Proceedings
000827199 300__ $$a21 - 22
000827199 3367_ $$2ORCID$$aCONFERENCE_PAPER
000827199 3367_ $$033$$2EndNote$$aConference Paper
000827199 3367_ $$2BibTeX$$aINPROCEEDINGS
000827199 3367_ $$2DRIVER$$aconferenceObject
000827199 3367_ $$2DataCite$$aOutput Types/Conference Paper
000827199 3367_ $$0PUB:(DE-HGF)8$$2PUB:(DE-HGF)$$aContribution to a conference proceedings$$bcontrib$$mcontrib$$s1485877306_18207
000827199 3367_ $$0PUB:(DE-HGF)7$$2PUB:(DE-HGF)$$aContribution to a book$$mcontb
000827199 520__ $$aElectron tomography (ET) is an important technique for the study of the three dimensional morphology, structure and chemical composition of nanoscale materials in the transmission electron microscope (TEM). Although ET is potentially a powerful tool for in situ three-dimensional TEM studies of catalytic reactions, growth processes, phase transformations, switching mechanisms and defect nucleation, motion and interactions, its application to dynamic experiments has been limited, since typical acquisition times for tilt series are typically tens of minutes or longer [1].We have recently demonstrated the rapid acquisition of a tomographic tilt series comprising approximately 3500 images between +30° and −70° in only 3.5 s, as shown in Fig. 1) [2]. Here, we apply the technique to the three-dimensional imaging of the thermal segregation of an InAs V-shaped nanomembrane [3]. The membrane was heated in situ in an FEI Titan TEM up to a temperature of 420 °C. Changes in membrane morphology were tracked by acquiring images on a Gatan K2-IS camera at 400 frames per second while continuously tilting the specimen between +60° and −65°. Each tilt series (i.e., one rotation in one direction) was acquired in approximately 4.3 s and comprised ~1700 frames. Selected frames are shown in Figs 2 and 3.The reconstruction of time-dependent (four-dimensional) tilt series can be performed using two approaches: i) Reconstruction of each individual tilt series and interpolation between each reconstruction in the time domain, resulting in a time resolution that is limited by the acquisition time for each tilt series (i.e., 4.3 s); ii) Model-based reconstruction, involving tracking of changes between individual frames within each tilt series, resulting in sub-second temporal resolution. We are presently pursuing both approaches.We are grateful to Cory Czarnik and Ana Pakzad from Gatan Inc. for making the K2 IS camera available for the experiments and to the European Research Council for an Advanced Grant.
000827199 536__ $$0G:(DE-HGF)POF3-143$$a143 - Controlling Configuration-Based Phenomena (POF3-143)$$cPOF3-143$$fPOF III$$x0
000827199 588__ $$aDataset connected to CrossRef Book
000827199 7001_ $$0P:(DE-HGF)0$$aLeary, Rowan K.$$b1
000827199 7001_ $$0P:(DE-HGF)0$$ade la Mata, María$$b2
000827199 7001_ $$0P:(DE-HGF)0$$aRusso-Averchi, Eleonora$$b3
000827199 7001_ $$0P:(DE-HGF)0$$aTütüncüoglu, Gözde$$b4
000827199 7001_ $$0P:(DE-HGF)0$$aMorral, Anna Fontcuberta i$$b5
000827199 7001_ $$0P:(DE-HGF)0$$aArbiol, Jordi$$b6
000827199 7001_ $$0P:(DE-Juel1)144121$$aDunin-Borkowski, Rafal$$b7
000827199 773__ $$a10.1002/9783527808465.EMC2016.6191
000827199 8564_ $$uhttps://juser.fz-juelich.de/record/827199/files/emc20166191.pdf$$yRestricted
000827199 8564_ $$uhttps://juser.fz-juelich.de/record/827199/files/emc20166191.gif?subformat=icon$$xicon$$yRestricted
000827199 8564_ $$uhttps://juser.fz-juelich.de/record/827199/files/emc20166191.jpg?subformat=icon-1440$$xicon-1440$$yRestricted
000827199 8564_ $$uhttps://juser.fz-juelich.de/record/827199/files/emc20166191.jpg?subformat=icon-180$$xicon-180$$yRestricted
000827199 8564_ $$uhttps://juser.fz-juelich.de/record/827199/files/emc20166191.jpg?subformat=icon-640$$xicon-640$$yRestricted
000827199 8564_ $$uhttps://juser.fz-juelich.de/record/827199/files/emc20166191.pdf?subformat=pdfa$$xpdfa$$yRestricted
000827199 909CO $$ooai:juser.fz-juelich.de:827199$$pVDB
000827199 9141_ $$y2016
000827199 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)159136$$aForschungszentrum Jülich$$b0$$kFZJ
000827199 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)144121$$aForschungszentrum Jülich$$b7$$kFZJ
000827199 9131_ $$0G:(DE-HGF)POF3-143$$1G:(DE-HGF)POF3-140$$2G:(DE-HGF)POF3-100$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bEnergie$$lFuture Information Technology - Fundamentals, Novel Concepts and Energy Efficiency (FIT)$$vControlling Configuration-Based Phenomena$$x0
000827199 920__ $$lyes
000827199 9201_ $$0I:(DE-Juel1)PGI-5-20110106$$kPGI-5$$lMikrostrukturforschung$$x0
000827199 9201_ $$0I:(DE-Juel1)ER-C-1-20170209$$kER-C-1$$lPhysik Nanoskaliger Systeme$$x1
000827199 980__ $$acontrib
000827199 980__ $$aVDB
000827199 980__ $$acontb
000827199 980__ $$aI:(DE-Juel1)PGI-5-20110106
000827199 980__ $$aI:(DE-Juel1)ER-C-1-20170209
000827199 980__ $$aUNRESTRICTED
000827199 981__ $$aI:(DE-Juel1)ER-C-1-20170209