000834290 001__ 834290
000834290 005__ 20240711101502.0
000834290 0247_ $$2doi$$a10.1016/j.jpowsour.2017.11.075
000834290 0247_ $$2ISSN$$a0378-7753
000834290 0247_ $$2ISSN$$a1873-2755
000834290 0247_ $$2WOS$$aWOS:000424070900009
000834290 037__ $$aFZJ-2017-04272
000834290 082__ $$a620
000834290 1001_ $$0P:(DE-Juel1)168338$$aXu, Liangfei$$b0$$eCorresponding author
000834290 245__ $$aDesing of Durability Test Protocol for Vehicular Fuel Cell System Operated in Power Follow Mode Based on Statistic Results of On-Road Data
000834290 260__ $$aNew York, NY [u.a.]$$bElsevier$$c2017
000834290 3367_ $$2DRIVER$$aarticle
000834290 3367_ $$2DataCite$$aOutput Types/Journal article
000834290 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1515393120_28980
000834290 3367_ $$2BibTeX$$aARTICLE
000834290 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000834290 3367_ $$00$$2EndNote$$aJournal Article
000834290 520__ $$aCity buses using polymer electrolyte membrane (PEM) fuel cells are considered to be the most likely fuel cell vehicles to be commercialized in China. The technical specifications of the fuel cell systems (FCSs) these buses are equipped with will differ based on the powertrain configurations and vehicle control strategies, but can generally be classified into the power-follow and soft-run modes. Each mode imposes different levels of electrochemical stress on the fuel cells. Evaluating the aging behavior of fuel cell stacks under the conditions encountered in fuel cell buses requires new durability test protocols based on statistical results obtained during actual driving tests. In this study, we propose a systematic design method for fuel cell durability test protocols that correspond to the power-follow mode based on three parameters for different fuel cell load ranges. The powertrain configurations and control strategy are described herein, followed by a presentation of the statistical data for the duty cycles of FCSs in one city bus in the demonstration project. Assessment protocols are presented based on the statistical results using mathematical optimization methods, and are compared to existing protocols with respect to common factors, such as time at open circuit voltage and root-mean-square power.
000834290 536__ $$0G:(DE-HGF)POF3-135$$a135 - Fuel Cells (POF3-135)$$cPOF3-135$$fPOF III$$x0
000834290 588__ $$aDataset connected to CrossRef
000834290 7001_ $$0P:(DE-Juel1)6697$$aReimer, Uwe$$b1
000834290 7001_ $$0P:(DE-HGF)0$$aLi, Jianqiu$$b2
000834290 7001_ $$0P:(DE-HGF)0$$aHuang, Haiyan$$b3
000834290 7001_ $$0P:(DE-Juel1)129863$$aJanssen, Holger$$b4
000834290 7001_ $$0P:(DE-HGF)0$$aOuyang, Minggao$$b5
000834290 7001_ $$0P:(DE-Juel1)129883$$aLehnert, Werner$$b6
000834290 773__ $$0PERI:(DE-600)1491915-1$$a10.1016/j.jpowsour.2017.11.075$$gVol. 377, p. 59 - 69$$p59 - 69$$tJournal of power sources$$v377$$x0378-7753$$y2017
000834290 8564_ $$uhttps://juser.fz-juelich.de/record/834290/files/1-s2.0-S0378775317315586-main.pdf$$yRestricted
000834290 8564_ $$uhttps://juser.fz-juelich.de/record/834290/files/1-s2.0-S0378775317315586-main.gif?subformat=icon$$xicon$$yRestricted
000834290 8564_ $$uhttps://juser.fz-juelich.de/record/834290/files/1-s2.0-S0378775317315586-main.jpg?subformat=icon-1440$$xicon-1440$$yRestricted
000834290 8564_ $$uhttps://juser.fz-juelich.de/record/834290/files/1-s2.0-S0378775317315586-main.jpg?subformat=icon-180$$xicon-180$$yRestricted
000834290 8564_ $$uhttps://juser.fz-juelich.de/record/834290/files/1-s2.0-S0378775317315586-main.jpg?subformat=icon-640$$xicon-640$$yRestricted
000834290 8564_ $$uhttps://juser.fz-juelich.de/record/834290/files/1-s2.0-S0378775317315586-main.pdf?subformat=pdfa$$xpdfa$$yRestricted
000834290 909CO $$ooai:juser.fz-juelich.de:834290$$pVDB
000834290 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)168338$$aForschungszentrum Jülich$$b0$$kFZJ
000834290 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)6697$$aForschungszentrum Jülich$$b1$$kFZJ
000834290 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129863$$aForschungszentrum Jülich$$b4$$kFZJ
000834290 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129883$$aForschungszentrum Jülich$$b6$$kFZJ
000834290 9131_ $$0G:(DE-HGF)POF3-135$$1G:(DE-HGF)POF3-130$$2G:(DE-HGF)POF3-100$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bEnergie$$lSpeicher und vernetzte Infrastrukturen$$vFuel Cells$$x0
000834290 9141_ $$y2017
000834290 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bJ POWER SOURCES : 2015
000834290 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS
000834290 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline
000834290 915__ $$0StatID:(DE-HGF)0310$$2StatID$$aDBCoverage$$bNCBI Molecular Biology Database
000834290 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search
000834290 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC
000834290 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bThomson Reuters Master Journal List
000834290 915__ $$0StatID:(DE-HGF)0110$$2StatID$$aWoS$$bScience Citation Index
000834290 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection
000834290 915__ $$0StatID:(DE-HGF)0111$$2StatID$$aWoS$$bScience Citation Index Expanded
000834290 915__ $$0StatID:(DE-HGF)1150$$2StatID$$aDBCoverage$$bCurrent Contents - Physical, Chemical and Earth Sciences
000834290 915__ $$0StatID:(DE-HGF)1160$$2StatID$$aDBCoverage$$bCurrent Contents - Engineering, Computing and Technology
000834290 915__ $$0StatID:(DE-HGF)9905$$2StatID$$aIF >= 5$$bJ POWER SOURCES : 2015
000834290 920__ $$lyes
000834290 9201_ $$0I:(DE-Juel1)IEK-3-20101013$$kIEK-3$$lElektrochemische Verfahrenstechnik$$x0
000834290 980__ $$ajournal
000834290 980__ $$aVDB
000834290 980__ $$aI:(DE-Juel1)IEK-3-20101013
000834290 980__ $$aUNRESTRICTED
000834290 981__ $$aI:(DE-Juel1)ICE-2-20101013