000834300 001__ 834300
000834300 005__ 20241127124646.0
000834300 0247_ $$2doi$$a10.1016/j.ijhydene.2017.05.230
000834300 0247_ $$2ISSN$$a0360-3199
000834300 0247_ $$2ISSN$$a1879-3487
000834300 0247_ $$2WOS$$aWOS:000406725500004
000834300 037__ $$aFZJ-2017-04282
000834300 082__ $$a660
000834300 1001_ $$0P:(DE-Juel1)129902$$aPeters, Ralf$$b0$$eCorresponding author
000834300 245__ $$aSpray Formation of Middle Destillates for Autothermal Reforming
000834300 260__ $$aNew York, NY [u.a.]$$bElsevier$$c2017
000834300 3367_ $$2DRIVER$$aarticle
000834300 3367_ $$2DataCite$$aOutput Types/Journal article
000834300 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1515579359_18136
000834300 3367_ $$2BibTeX$$aARTICLE
000834300 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000834300 3367_ $$00$$2EndNote$$aJournal Article
000834300 520__ $$aThe reforming of diesel and diesel-like fuels plays a central role in the development of fuel cell systems for on-board power supplies. The vaporization of the fuel via a spray formation and the subsequent mixture with water vapor and air determine the quality of the reforming process, as is shown in this paper. By using a high quality nozzle residual hydrocarbons were below 25 ppmV during the reforming of standard diesel. Through the use of a fuel injector in pulsed operation, the load range was able to be increased from 1:1.67 to 1:6. Spray pattern analyses were conducted using a high-speed camera. The formation of the spray pattern lasted 1.5–2 ms. The testing of a fast-closing magnetic valve manufactured by GSR Ventiltechnik was carried out on the autothermal reformer (ATR) type AH2. It exist not any direct influence of the pulsed operation on hydrogen production.
000834300 536__ $$0G:(DE-HGF)POF3-135$$a135 - Fuel Cells (POF3-135)$$cPOF3-135$$fPOF III$$x0
000834300 588__ $$aDataset connected to CrossRef
000834300 7001_ $$0P:(DE-Juel1)129898$$aPasel, Joachim$$b1
000834300 7001_ $$0P:(DE-Juel1)207065$$aSamsun, Remzi Can$$b2
000834300 7001_ $$0P:(DE-HGF)0$$aScharf, Florian$$b3
000834300 7001_ $$0P:(DE-Juel1)129935$$aTschauder, Andreas$$b4
000834300 7001_ $$0P:(DE-HGF)0$$aMüller, Michael$$b5
000834300 7001_ $$0P:(DE-HGF)0$$aMüller, Axel$$b6
000834300 7001_ $$0P:(DE-HGF)0$$aBeer, Michael$$b7
000834300 7001_ $$0P:(DE-Juel1)129928$$aStolten, Detlef$$b8
000834300 773__ $$0PERI:(DE-600)1484487-4$$a10.1016/j.ijhydene.2017.05.230$$gVol. 42, no. 27, p. 16946 - 16960$$n27$$p16946 - 16960$$tInternational journal of hydrogen energy$$v42$$x0360-3199$$y2017
000834300 8564_ $$uhttps://juser.fz-juelich.de/record/834300/files/1-s2.0-S0360319917322140-main.pdf$$yRestricted
000834300 8564_ $$uhttps://juser.fz-juelich.de/record/834300/files/1-s2.0-S0360319917322140-main.gif?subformat=icon$$xicon$$yRestricted
000834300 8564_ $$uhttps://juser.fz-juelich.de/record/834300/files/1-s2.0-S0360319917322140-main.jpg?subformat=icon-1440$$xicon-1440$$yRestricted
000834300 8564_ $$uhttps://juser.fz-juelich.de/record/834300/files/1-s2.0-S0360319917322140-main.jpg?subformat=icon-180$$xicon-180$$yRestricted
000834300 8564_ $$uhttps://juser.fz-juelich.de/record/834300/files/1-s2.0-S0360319917322140-main.jpg?subformat=icon-640$$xicon-640$$yRestricted
000834300 8564_ $$uhttps://juser.fz-juelich.de/record/834300/files/1-s2.0-S0360319917322140-main.pdf?subformat=pdfa$$xpdfa$$yRestricted
000834300 909CO $$ooai:juser.fz-juelich.de:834300$$pVDB
000834300 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129902$$aForschungszentrum Jülich$$b0$$kFZJ
000834300 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129898$$aForschungszentrum Jülich$$b1$$kFZJ
000834300 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)207065$$aForschungszentrum Jülich$$b2$$kFZJ
000834300 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129935$$aForschungszentrum Jülich$$b4$$kFZJ
000834300 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129928$$aForschungszentrum Jülich$$b8$$kFZJ
000834300 9131_ $$0G:(DE-HGF)POF3-135$$1G:(DE-HGF)POF3-130$$2G:(DE-HGF)POF3-100$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bEnergie$$lSpeicher und vernetzte Infrastrukturen$$vFuel Cells$$x0
000834300 9141_ $$y2017
000834300 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bINT J HYDROGEN ENERG : 2015
000834300 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS
000834300 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline
000834300 915__ $$0StatID:(DE-HGF)0310$$2StatID$$aDBCoverage$$bNCBI Molecular Biology Database
000834300 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search
000834300 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC
000834300 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bThomson Reuters Master Journal List
000834300 915__ $$0StatID:(DE-HGF)0110$$2StatID$$aWoS$$bScience Citation Index
000834300 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection
000834300 915__ $$0StatID:(DE-HGF)0111$$2StatID$$aWoS$$bScience Citation Index Expanded
000834300 915__ $$0StatID:(DE-HGF)1160$$2StatID$$aDBCoverage$$bCurrent Contents - Engineering, Computing and Technology
000834300 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5
000834300 920__ $$lyes
000834300 9201_ $$0I:(DE-Juel1)IEK-3-20101013$$kIEK-3$$lElektrochemische Verfahrenstechnik$$x0
000834300 980__ $$ajournal
000834300 980__ $$aVDB
000834300 980__ $$aI:(DE-Juel1)IEK-3-20101013
000834300 980__ $$aUNRESTRICTED
000834300 981__ $$aI:(DE-Juel1)ICE-2-20101013