      author       = {Pintsuk, G. and Bellin, B. and Gervash, A. and Linke, J.
                      and Litunovsky, N. and Lorenzetto, P.},
      title        = {{H}igh heat flux testing of first wall mock-ups with and
                      without neutron irradiation},
      journal      = {Nuclear materials and energy},
      volume       = {9},
      issn         = {2352-1791},
      address      = {Amsterdam [u.a.]},
      publisher    = {Elsevier},
      reportid     = {FZJ-2017-06245},
      pages        = {41 - 45},
      year         = {2016},
      abstract     = {Beryllium as the plasma facing material for the first wall
                      of ITER will be exposed to thermal, particle and neutron
                      loads. In the frame of the European qualification program
                      for ITER, two HIPped beryllium small scale flat-tile
                      mock-ups consisting of a steel support structure, a
                      CuCrZr/Cu heat sink and two beryllium tiles on top were
                      manufactured by CEA. One mock-up was exposed to neutron
                      irradiation up to 0.75 dpa in beryllium in the RBT-6 fission
                      reactor at Dimitrovgrad, Russia, while the other one was
                      kept as reference. Furthermore, an identical mock-up was
                      produced in Russia by manufacturing via electron beam
                      induced rapid brazing and also exposed to the same neutron
                      irradiation conditions.For qualification, all three
                      flat-tile mock-ups were exposed to cyclic steady state heat
                      loads in the electron beam facility JUDITH-1 up to a maximum
                      of 3.0 MW/m2. Thereby, each tile was loaded individually as
                      the full loading area exceeds the limits of the facility.},
      cin          = {IEK-4},
      ddc          = {333.7},
      cid          = {I:(DE-Juel1)IEK-4-20101013},
      pnm          = {174 - Plasma-Wall-Interaction (POF3-174)},
      pid          = {G:(DE-HGF)POF3-174},
      typ          = {PUB:(DE-HGF)16},
      UT           = {WOS:000391191500007},
      doi          = {10.1016/j.nme.2016.02.003},
      url          = {https://juser.fz-juelich.de/record/837276},
}