001     837559
005     20240619091230.0
024 7 _ |a 10.1587/transele.E100.C.269
|2 doi
024 7 _ |a 0916-8524
|2 ISSN
024 7 _ |a 1745-1353
|2 ISSN
024 7 _ |a WOS:000399373200007
|2 WOS
024 7 _ |a 2128/20690
|2 Handle
037 _ _ |a FZJ-2017-06447
082 _ _ |a 620
100 1 _ |a TANAKA, Saburo
|0 P:(DE-HGF)0
|b 0
245 _ _ |a Prototype of Multi-Channel High-Tc SQUID Metallic Contaminant Detector for Large Sized Packaged Food
260 _ _ |a Tokyo
|c 2017
|b IEICE
336 7 _ |a article
|2 DRIVER
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1504853548_17820
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
520 _ _ |a We report on the fabrication of a magnetic metallic contaminant detector using multi-channel high-Tc RF-SQUIDs (superconducting quantum interference devices) for large packaged food. For food safety finding small metallic contaminants is an important issue for a food manufacturer. Hence, a detection method for small sized contaminants is required. Some detection systems for food inspection using high-Tc SQUIDs have been reported to date. The system described here is different from the previous systems in its permitted size for inspection, being larger at 150mm in height × 300mm in width. For inspection of large sized food packages, improvement of the signal to noise ratio (SNR) is an important issue because the signal intensity is inversely proportional to the cube of the distance between the SQUID sensor and the object. Therefore a digital filter was introduced and its parameters were optimized. As a result, a steel ball as small as 0.5mm in diameter at a stand-off distance of 167mm was successfully detected with more than SNR = 3.3.
536 _ _ |a 523 - Controlling Configuration-Based Phenomena (POF3-523)
|0 G:(DE-HGF)POF3-523
|c POF3-523
|f POF III
|x 0
588 _ _ |a Dataset connected to CrossRef
700 1 _ |a OHTANI, Takeyoshi
|0 P:(DE-HGF)0
|b 1
700 1 _ |a KRAUSE, Hans-Joachim
|0 P:(DE-Juel1)128697
|b 2
|u fzj
773 _ _ |a 10.1587/transele.E100.C.269
|g Vol. E100.C, no. 3, p. 269 - 273
|0 PERI:(DE-600)2214514-X
|n 3
|p 269 - 273
|t IEICE transactions / E / C
|v E100.C
|y 2017
|x 1745-1353
856 4 _ |y OpenAccess
|u https://juser.fz-juelich.de/record/837559/files/E100.C_269-1.pdf
856 4 _ |y OpenAccess
|x pdfa
|u https://juser.fz-juelich.de/record/837559/files/E100.C_269-1.pdf?subformat=pdfa
909 C O |o oai:juser.fz-juelich.de:837559
|p openaire
|p open_access
|p VDB
|p driver
|p dnbdelivery
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 2
|6 P:(DE-Juel1)128697
913 1 _ |a DE-HGF
|b Key Technologies
|l Future Information Technology - Fundamentals, Novel Concepts and Energy Efficiency (FIT)
|1 G:(DE-HGF)POF3-520
|0 G:(DE-HGF)POF3-523
|2 G:(DE-HGF)POF3-500
|v Controlling Configuration-Based Phenomena
|x 0
|4 G:(DE-HGF)POF
|3 G:(DE-HGF)POF3
914 1 _ |y 2017
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0150
|2 StatID
|b Web of Science Core Collection
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1160
|2 StatID
|b Current Contents - Engineering, Computing and Technology
915 _ _ |a OpenAccess
|0 StatID:(DE-HGF)0510
|2 StatID
915 _ _ |a JCR
|0 StatID:(DE-HGF)0100
|2 StatID
|b IEICE T ELECTRON : 2015
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
915 _ _ |a WoS
|0 StatID:(DE-HGF)0111
|2 StatID
|b Science Citation Index Expanded
915 _ _ |a IF < 5
|0 StatID:(DE-HGF)9900
|2 StatID
915 _ _ |a Allianz-Lizenz / DFG
|0 StatID:(DE-HGF)0400
|2 StatID
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0199
|2 StatID
|b Thomson Reuters Master Journal List
920 _ _ |l yes
920 1 _ |0 I:(DE-Juel1)ICS-8-20110106
|k ICS-8
|l Bioelektronik
|x 0
980 1 _ |a FullTexts
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a UNRESTRICTED
980 _ _ |a I:(DE-Juel1)ICS-8-20110106
981 _ _ |a I:(DE-Juel1)IBI-3-20200312


LibraryCollectionCLSMajorCLSMinorLanguageAuthor