% IMPORTANT: The following is UTF-8 encoded.  This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.

@ARTICLE{Sergienko:838754,
      author       = {Sergienko, G. and Esser, H. G. and Kirschner, A. and Huber,
                      A. and Freisinger, M. and Brezinsek, S. and Widdowson, A.
                      and Ayres, Ch. and Weckmann, A. and Heinola, K.},
      title        = {{Q}uartz micro-balance results of pulse-resolved
                      erosion/deposition in the {JET}-{ILW} divertor},
      journal      = {Nuclear materials and energy},
      volume       = {12},
      issn         = {2352-1791},
      address      = {Amsterdam [u.a.]},
      publisher    = {Elsevier},
      reportid     = {FZJ-2017-07291},
      pages        = {478-482},
      year         = {2017},
      abstract     = {A set of quartz crystal microbalances (QMB) was used at JET
                      with full carbon wall to monitor mass erosion/deposition
                      rates in the remote areas of the divertor. After
                      introduction of the ITER- like wall (ILW) in JET with
                      beryllium main wall and tungsten divertor, strong reduction
                      of the material deposition and accompanied fuel retention
                      was observed. Therefore the existing QMB electronics have
                      been modified to improve the accuracy of frequency
                      measurements by a factor of ten down to 0.1 Hz which
                      corresponds to 1.4 ng cm−2. The averaged deposition rates
                      of 1.2–3 ng cm−2 s−1 and erosion rates of 5.6–8.1 ng
                      cm−2 s−1 were observed in the inner divertor of JET -ILW
                      with the inner strike point positions close to the bottom
                      edge of vertical tile 3 and at the horizontal tile 4
                      respectively. The erosion with averaged rates of ≈2.1 ng
                      cm−2 s−1 and ≈120 ng cm−2 s−1 were observed in the
                      outer divertor for the outer strike point positions at tile
                      5 and tile 6 respectively.},
      cin          = {IEK-4},
      ddc          = {333.7},
      cid          = {I:(DE-Juel1)IEK-4-20101013},
      pnm          = {174 - Plasma-Wall-Interaction (POF3-174)},
      pid          = {G:(DE-HGF)POF3-174},
      typ          = {PUB:(DE-HGF)16},
      UT           = {WOS:000417293300074},
      doi          = {10.1016/j.nme.2017.03.007},
      url          = {https://juser.fz-juelich.de/record/838754},
}