000838906 001__ 838906
000838906 005__ 20240711101521.0
000838906 0247_ $$2doi$$a10.1016/j.ijhydene.2017.06.035
000838906 0247_ $$2ISSN$$a0360-3199
000838906 0247_ $$2ISSN$$a1879-3487
000838906 0247_ $$2WOS$$aWOS:000408297500041
000838906 037__ $$aFZJ-2017-07412
000838906 082__ $$a660
000838906 1001_ $$00000-0002-2148-6172$$aHong, Po$$b0
000838906 245__ $$aA new approach to online AC impedance measurement at high frequency of PEM fuel cell stack
000838906 260__ $$aNew York, NY [u.a.]$$bElsevier$$c2017
000838906 3367_ $$2DRIVER$$aarticle
000838906 3367_ $$2DataCite$$aOutput Types/Journal article
000838906 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1510318308_27059
000838906 3367_ $$2BibTeX$$aARTICLE
000838906 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000838906 3367_ $$00$$2EndNote$$aJournal Article
000838906 520__ $$aIn the PEM fuel cell system, the water management strategy is founded on the accurate water content estimation while until now it is still a large obstacle that prevents the application in the field of transportation. Focused on this problem, approaches such as the multi-mixture model have been put forward to estimate the water content but there exist some limitations. Some recent literature work shows that if they are combined with the AC impedance measurement at high frequency the estimation accuracy will be further improved. Hence, in this paper a new approach to online AC impedance measurement at high frequency is proposed by paralleling a DC/DC converter with the PEM fuel cell stack. Then the mathematical model of the stack and the converter is developed and analyzed to verify the feasibility of this method. After that, the DC/DC converter is designed and an experiment is performed on a 30 kW stack of 120-serial cells. To calculate the impedance of a cell, the cell voltage monitor is used to simultaneously measure the output current of the stack and the voltage of each cell and this device is experimentally calibrated. Under pre-scheduled experiment conditions, the variation trend of the impedance at 320 Hz of two cells in serial as a unit validates the capability of AC impedance measurement at high frequency using the DC/DC converter.
000838906 536__ $$0G:(DE-HGF)POF3-135$$a135 - Fuel Cells (POF3-135)$$cPOF3-135$$fPOF III$$x0
000838906 588__ $$aDataset connected to CrossRef
000838906 7001_ $$0P:(DE-Juel1)168338$$aXu, Liangfei$$b1
000838906 7001_ $$0P:(DE-HGF)0$$aJiang, Hongliang$$b2
000838906 7001_ $$0P:(DE-HGF)0$$aLi, Jianqiu$$b3$$eCorresponding author
000838906 7001_ $$0P:(DE-HGF)0$$aOuyang, Minggao$$b4
000838906 773__ $$0PERI:(DE-600)1484487-4$$a10.1016/j.ijhydene.2017.06.035$$gVol. 42, no. 30, p. 19156 - 19169$$n30$$p19156 - 19169$$tInternational journal of hydrogen energy$$v42$$x0360-3199$$y2017
000838906 8564_ $$uhttps://juser.fz-juelich.de/record/838906/files/1-s2.0-S0360319917323017-main.pdf$$yRestricted
000838906 8564_ $$uhttps://juser.fz-juelich.de/record/838906/files/1-s2.0-S0360319917323017-main.gif?subformat=icon$$xicon$$yRestricted
000838906 8564_ $$uhttps://juser.fz-juelich.de/record/838906/files/1-s2.0-S0360319917323017-main.jpg?subformat=icon-1440$$xicon-1440$$yRestricted
000838906 8564_ $$uhttps://juser.fz-juelich.de/record/838906/files/1-s2.0-S0360319917323017-main.jpg?subformat=icon-180$$xicon-180$$yRestricted
000838906 8564_ $$uhttps://juser.fz-juelich.de/record/838906/files/1-s2.0-S0360319917323017-main.jpg?subformat=icon-640$$xicon-640$$yRestricted
000838906 8564_ $$uhttps://juser.fz-juelich.de/record/838906/files/1-s2.0-S0360319917323017-main.pdf?subformat=pdfa$$xpdfa$$yRestricted
000838906 909CO $$ooai:juser.fz-juelich.de:838906$$pVDB
000838906 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)168338$$aForschungszentrum Jülich$$b1$$kFZJ
000838906 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-HGF)0$$aForschungszentrum Jülich$$b3$$kFZJ
000838906 9131_ $$0G:(DE-HGF)POF3-135$$1G:(DE-HGF)POF3-130$$2G:(DE-HGF)POF3-100$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bEnergie$$lSpeicher und vernetzte Infrastrukturen$$vFuel Cells$$x0
000838906 9141_ $$y2017
000838906 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bINT J HYDROGEN ENERG : 2015
000838906 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS
000838906 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline
000838906 915__ $$0StatID:(DE-HGF)0310$$2StatID$$aDBCoverage$$bNCBI Molecular Biology Database
000838906 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search
000838906 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC
000838906 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bThomson Reuters Master Journal List
000838906 915__ $$0StatID:(DE-HGF)0110$$2StatID$$aWoS$$bScience Citation Index
000838906 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection
000838906 915__ $$0StatID:(DE-HGF)0111$$2StatID$$aWoS$$bScience Citation Index Expanded
000838906 915__ $$0StatID:(DE-HGF)1160$$2StatID$$aDBCoverage$$bCurrent Contents - Engineering, Computing and Technology
000838906 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5
000838906 920__ $$lyes
000838906 9201_ $$0I:(DE-Juel1)IEK-3-20101013$$kIEK-3$$lElektrochemische Verfahrenstechnik$$x0
000838906 980__ $$ajournal
000838906 980__ $$aVDB
000838906 980__ $$aI:(DE-Juel1)IEK-3-20101013
000838906 980__ $$aUNRESTRICTED
000838906 981__ $$aI:(DE-Juel1)ICE-2-20101013