000839966 001__ 839966
000839966 005__ 20240711085656.0
000839966 0247_ $$2doi$$a10.1016/j.jpowsour.2017.11.025
000839966 0247_ $$2ISSN$$a0378-7753
000839966 0247_ $$2ISSN$$a1873-2755
000839966 0247_ $$2WOS$$aWOS:000418391900009
000839966 037__ $$aFZJ-2017-07540
000839966 041__ $$aEnglish
000839966 082__ $$a620
000839966 1001_ $$0P:(DE-Juel1)129636$$aMenzler, Norbert H.$$b0$$eCorresponding author
000839966 245__ $$aPost-test characterization of a solid oxide fuel cell stack operated for more than 30,000 hours: The cell
000839966 260__ $$aNew York, NY [u.a.]$$bElsevier$$c2018
000839966 3367_ $$2DRIVER$$aarticle
000839966 3367_ $$2DataCite$$aOutput Types/Journal article
000839966 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1513683962_27845
000839966 3367_ $$2BibTeX$$aARTICLE
000839966 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000839966 3367_ $$00$$2EndNote$$aJournal Article
000839966 520__ $$aA four-layer solid oxide fuel cell stack with planar anode-supported cells was operated galvanostatically at 700 °C and 0.5Acm−2 for nearly 35,000 h. One of the four planes started to degrade more rapidly after ∼28,000 h and finally more progressively after ∼33,000 h. The stack was then shut down and a post-test analysis was carefully performed. The cell was characterized with respect to cathodic impurities and clarification of the reason(s) for failure. Wet chemical analysis revealed very low chromium incorporation into the cathode. However, SEM and TEM observations on polished and fractured surfaces showed catastrophic failure in the degraded layer. The cathode–barrier–electrolyte cell layer system delaminated from the entire cell over large areas. The source of delamination was the formation of a porous, sponge-like secondary phase consisting of zirconia, yttria and manganese (oxide). Large secondary phase islands grew from the electrolyte–anode interface towards the anode and cracked the bonding between both layers. The manganese originated from the contact or protection layers used on the air side. This stack result shows that volatile species – in this case manganese – should be avoided, especially when long-term applications are envisaged.
000839966 536__ $$0G:(DE-HGF)POF3-135$$a135 - Fuel Cells (POF3-135)$$cPOF3-135$$fPOF III$$x0
000839966 536__ $$0G:(DE-Juel1)SOFC-20140602$$aSOFC - Solid Oxide Fuel Cell (SOFC-20140602)$$cSOFC-20140602$$fSOFC$$x1
000839966 588__ $$aDataset connected to CrossRef
000839966 7001_ $$0P:(DE-Juel1)129662$$aSebold, Doris$$b1
000839966 7001_ $$0P:(DE-Juel1)161591$$aGuillon, Olivier$$b2$$ufzj
000839966 773__ $$0PERI:(DE-600)1491915-1$$a10.1016/j.jpowsour.2017.11.025$$gVol. 374, p. 69 - 76$$p69 - 76$$tJournal of power sources$$v374$$x0378-7753$$y2018
000839966 8564_ $$uhttps://juser.fz-juelich.de/record/839966/files/1-s2.0-S0378775317314842-main.pdf$$yRestricted
000839966 8564_ $$uhttps://juser.fz-juelich.de/record/839966/files/1-s2.0-S0378775317314842-main.gif?subformat=icon$$xicon$$yRestricted
000839966 8564_ $$uhttps://juser.fz-juelich.de/record/839966/files/1-s2.0-S0378775317314842-main.jpg?subformat=icon-1440$$xicon-1440$$yRestricted
000839966 8564_ $$uhttps://juser.fz-juelich.de/record/839966/files/1-s2.0-S0378775317314842-main.jpg?subformat=icon-180$$xicon-180$$yRestricted
000839966 8564_ $$uhttps://juser.fz-juelich.de/record/839966/files/1-s2.0-S0378775317314842-main.jpg?subformat=icon-640$$xicon-640$$yRestricted
000839966 8564_ $$uhttps://juser.fz-juelich.de/record/839966/files/1-s2.0-S0378775317314842-main.pdf?subformat=pdfa$$xpdfa$$yRestricted
000839966 909CO $$ooai:juser.fz-juelich.de:839966$$pVDB
000839966 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129636$$aForschungszentrum Jülich$$b0$$kFZJ
000839966 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129662$$aForschungszentrum Jülich$$b1$$kFZJ
000839966 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)161591$$aForschungszentrum Jülich$$b2$$kFZJ
000839966 9131_ $$0G:(DE-HGF)POF3-135$$1G:(DE-HGF)POF3-130$$2G:(DE-HGF)POF3-100$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bEnergie$$lSpeicher und vernetzte Infrastrukturen$$vFuel Cells$$x0
000839966 9141_ $$y2018
000839966 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bJ POWER SOURCES : 2015
000839966 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS
000839966 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline
000839966 915__ $$0StatID:(DE-HGF)0310$$2StatID$$aDBCoverage$$bNCBI Molecular Biology Database
000839966 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search
000839966 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC
000839966 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bThomson Reuters Master Journal List
000839966 915__ $$0StatID:(DE-HGF)0110$$2StatID$$aWoS$$bScience Citation Index
000839966 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection
000839966 915__ $$0StatID:(DE-HGF)0111$$2StatID$$aWoS$$bScience Citation Index Expanded
000839966 915__ $$0StatID:(DE-HGF)1150$$2StatID$$aDBCoverage$$bCurrent Contents - Physical, Chemical and Earth Sciences
000839966 915__ $$0StatID:(DE-HGF)1160$$2StatID$$aDBCoverage$$bCurrent Contents - Engineering, Computing and Technology
000839966 915__ $$0StatID:(DE-HGF)9905$$2StatID$$aIF >= 5$$bJ POWER SOURCES : 2015
000839966 920__ $$lyes
000839966 9201_ $$0I:(DE-Juel1)IEK-1-20101013$$kIEK-1$$lWerkstoffsynthese und Herstellungsverfahren$$x0
000839966 9201_ $$0I:(DE-82)080011_20140620$$kJARA-ENERGY$$lJARA-ENERGY$$x1
000839966 980__ $$ajournal
000839966 980__ $$aVDB
000839966 980__ $$aI:(DE-Juel1)IEK-1-20101013
000839966 980__ $$aI:(DE-82)080011_20140620
000839966 980__ $$aUNRESTRICTED
000839966 981__ $$aI:(DE-Juel1)IMD-2-20101013