001     840139
005     20240711101449.0
024 7 _ |a 10.1115/1.4038628
|2 doi
024 7 _ |a 2381-6872
|2 ISSN
024 7 _ |a 2381-6910
|2 ISSN
024 7 _ |a WOS:000427845700003
|2 WOS
037 _ _ |a FZJ-2017-07698
082 _ _ |a 620
100 1 _ |a Xu, Liangfei
|0 P:(DE-Juel1)168338
|b 0
|e Corresponding author
245 _ _ |a Self-humidification of a Proton Electrolyte Membrane Fuel Cell System with Cathodic Exhaust Gas Recirculation
260 _ _ |a New York, NY
|c 2018
|b ASME
336 7 _ |a article
|2 DRIVER
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1524551721_25912
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
520 _ _ |a Water management is critical for the operation of a polymer electrolyte membrane fuel cell (PEMFC). For the purposes of high power and long working-lifetime of PEMFCs, external humidifiers are always utilized as a necessary part of balance of plants to keep the imported air and fuel wet. However, they have several disadvantages, and it is beneficial to remove them so as to reduce system volume and to enhance the cold-starting capability. In this paper, a self-humidified PEMFC of an active area 250 cm2 and cell number 320 is proposed and investigated. The imported dry air on the cathode side is mixed with moisty exhaust gas by using a recirculation valve, and the dry hydrogen on the anode side is humidified by back-diffusion water through the membrane. A nonlinear model is set up based on mass transport and energy conservation equations to capture dynamics of gases in the supply and exhaust manifolds, the gas diffusion layers (GDLs), and the membrane. An analysis is conducted to investigate the influences of parameters on dynamic and stable performances. Simulation results show that system performances can be greatly affected by parameters such as air stoichiometry, current density, exhaust gas recirculation (EGR) ratio, and membrane thickness. By accurately controlling the EGR ratio and carefully selecting design and operation parameters, it is probably for a PEMFC without an external humidifier to have similar system efficiency compared to a traditional system.
536 _ _ |a 135 - Fuel Cells (POF3-135)
|0 G:(DE-HGF)POF3-135
|c POF3-135
|f POF III
|x 0
588 _ _ |a Dataset connected to CrossRef
700 1 _ |a Fang, Chuan
|0 P:(DE-HGF)0
|b 1
700 1 _ |a Hu, Junming
|0 P:(DE-HGF)0
|b 2
700 1 _ |a Cheng, Siliang
|0 P:(DE-HGF)0
|b 3
700 1 _ |a Li, Jianqiu
|0 P:(DE-HGF)0
|b 4
700 1 _ |a Ouyang, Minggao
|0 P:(DE-HGF)0
|b 5
700 1 _ |a Lehnert, Werner
|0 P:(DE-Juel1)129883
|b 6
|u fzj
773 _ _ |a 10.1115/1.4038628
|0 PERI:(DE-600)2866995-2
|n 2
|p 021003
|t Journal of electrochemical energy conversion and storage
|v 15
|y 2018
|x 2381-6872
856 4 _ |u https://juser.fz-juelich.de/record/840139/files/jeecs_015_02_021003.pdf
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/840139/files/jeecs_015_02_021003.gif?subformat=icon
|x icon
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/840139/files/jeecs_015_02_021003.jpg?subformat=icon-1440
|x icon-1440
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/840139/files/jeecs_015_02_021003.jpg?subformat=icon-180
|x icon-180
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/840139/files/jeecs_015_02_021003.jpg?subformat=icon-640
|x icon-640
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/840139/files/jeecs_015_02_021003.pdf?subformat=pdfa
|x pdfa
|y Restricted
909 C O |o oai:juser.fz-juelich.de:840139
|p VDB
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 6
|6 P:(DE-Juel1)129883
913 1 _ |a DE-HGF
|l Speicher und vernetzte Infrastrukturen
|1 G:(DE-HGF)POF3-130
|0 G:(DE-HGF)POF3-135
|2 G:(DE-HGF)POF3-100
|v Fuel Cells
|x 0
|4 G:(DE-HGF)POF
|3 G:(DE-HGF)POF3
|b Energie
914 1 _ |y 2018
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0199
|2 StatID
|b Thomson Reuters Master Journal List
915 _ _ |a WoS
|0 StatID:(DE-HGF)0111
|2 StatID
|b Science Citation Index Expanded
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0150
|2 StatID
|b Web of Science Core Collection
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1160
|2 StatID
|b Current Contents - Engineering, Computing and Technology
920 _ _ |l yes
920 1 _ |0 I:(DE-Juel1)IEK-3-20101013
|k IEK-3
|l Elektrochemische Verfahrenstechnik
|x 0
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a I:(DE-Juel1)IEK-3-20101013
980 _ _ |a UNRESTRICTED
981 _ _ |a I:(DE-Juel1)ICE-2-20101013


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21