000840173 001__ 840173
000840173 005__ 20210129231751.0
000840173 0247_ $$2doi$$a10.1017/S1431927616007790
000840173 0247_ $$2ISSN$$a1431-9276
000840173 0247_ $$2ISSN$$a1435-8115
000840173 0247_ $$2Handle$$a2128/19355
000840173 037__ $$aFZJ-2017-07728
000840173 082__ $$a570
000840173 1001_ $$0P:(DE-Juel1)131002$$aThust, Andreas$$b0$$ufzj
000840173 245__ $$aIs HRTEM Image Simulation Correct? A Premise-Free Calibration Approach
000840173 260__ $$aNew York, NY$$bCambridge University Press$$c2016
000840173 3367_ $$2DRIVER$$aarticle
000840173 3367_ $$2DataCite$$aOutput Types/Journal article
000840173 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1531743329_26644
000840173 3367_ $$2BibTeX$$aARTICLE
000840173 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000840173 3367_ $$00$$2EndNote$$aJournal Article
000840173 520__ $$aThe comparison of absolute image intensities between experiment and simulation in high-resolutiontransmission electron microscopy (HRTEM) is a long-standing problem, which led to a multitude ofdiscussions and speculations in the past. A huge contrast mismatch, which was first stated by Hytch andStobbs in 1994 [1], could be largely explained in 2009 as a consequence of neglecting the correctmodulation transfer function (MTF) of the recording camera in image simulation [2]. Further smallerrefinements to image simulation, which incorporate also the so-called image-spread effect [3], ledrecently to nearly perfect absolute-intensity matches between experiment and simulation [4,5].
000840173 536__ $$0G:(DE-HGF)POF3-143$$a143 - Controlling Configuration-Based Phenomena (POF3-143)$$cPOF3-143$$fPOF III$$x0
000840173 588__ $$aDataset connected to CrossRef
000840173 7001_ $$0P:(DE-Juel1)130525$$aBarthel, Juri$$b1$$ufzj
000840173 7001_ $$0P:(DE-Juel1)130736$$aJia, Chun-Lin$$b2$$ufzj
000840173 773__ $$0PERI:(DE-600)1481716-0$$a10.1017/S1431927616007790$$gVol. 22, no. S3, p. 1390 - 1391$$nS3$$p1390 - 1391$$tMicroscopy and microanalysis$$v22$$x1435-8115$$y2016
000840173 8564_ $$uhttps://juser.fz-juelich.de/record/840173/files/is_hrtem_image_simulation_correct_a_premisefree_calibration_approach.pdf$$yOpenAccess
000840173 8564_ $$uhttps://juser.fz-juelich.de/record/840173/files/is_hrtem_image_simulation_correct_a_premisefree_calibration_approach.gif?subformat=icon$$xicon$$yOpenAccess
000840173 8564_ $$uhttps://juser.fz-juelich.de/record/840173/files/is_hrtem_image_simulation_correct_a_premisefree_calibration_approach.jpg?subformat=icon-1440$$xicon-1440$$yOpenAccess
000840173 8564_ $$uhttps://juser.fz-juelich.de/record/840173/files/is_hrtem_image_simulation_correct_a_premisefree_calibration_approach.jpg?subformat=icon-180$$xicon-180$$yOpenAccess
000840173 8564_ $$uhttps://juser.fz-juelich.de/record/840173/files/is_hrtem_image_simulation_correct_a_premisefree_calibration_approach.jpg?subformat=icon-640$$xicon-640$$yOpenAccess
000840173 909CO $$ooai:juser.fz-juelich.de:840173$$pdnbdelivery$$pdriver$$pVDB$$popen_access$$popenaire
000840173 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)131002$$aForschungszentrum Jülich$$b0$$kFZJ
000840173 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)130525$$aForschungszentrum Jülich$$b1$$kFZJ
000840173 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)130736$$aForschungszentrum Jülich$$b2$$kFZJ
000840173 9131_ $$0G:(DE-HGF)POF3-143$$1G:(DE-HGF)POF3-140$$2G:(DE-HGF)POF3-100$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bEnergie$$lFuture Information Technology - Fundamentals, Novel Concepts and Energy Efficiency (FIT)$$vControlling Configuration-Based Phenomena$$x0
000840173 9141_ $$y2017
000840173 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS
000840173 915__ $$0StatID:(DE-HGF)1030$$2StatID$$aDBCoverage$$bCurrent Contents - Life Sciences
000840173 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bMICROSC MICROANAL : 2015
000840173 915__ $$0StatID:(DE-HGF)0520$$2StatID$$aAllianz-OA
000840173 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection
000840173 915__ $$0StatID:(DE-HGF)0110$$2StatID$$aWoS$$bScience Citation Index
000840173 915__ $$0StatID:(DE-HGF)0111$$2StatID$$aWoS$$bScience Citation Index Expanded
000840173 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000840173 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5
000840173 915__ $$0StatID:(DE-HGF)0400$$2StatID$$aAllianz-Lizenz / DFG
000840173 915__ $$0StatID:(DE-HGF)1150$$2StatID$$aDBCoverage$$bCurrent Contents - Physical, Chemical and Earth Sciences
000840173 915__ $$0StatID:(DE-HGF)0310$$2StatID$$aDBCoverage$$bNCBI Molecular Biology Database
000840173 915__ $$0StatID:(DE-HGF)1050$$2StatID$$aDBCoverage$$bBIOSIS Previews
000840173 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline
000840173 915__ $$0StatID:(DE-HGF)0420$$2StatID$$aNationallizenz
000840173 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bThomson Reuters Master Journal List
000840173 920__ $$lyes
000840173 9201_ $$0I:(DE-Juel1)ER-C-2-20170209$$kER-C-2$$lMaterialwissenschaft u. Werkstofftechnik$$x0
000840173 980__ $$ajournal
000840173 980__ $$aVDB
000840173 980__ $$aUNRESTRICTED
000840173 980__ $$aI:(DE-Juel1)ER-C-2-20170209
000840173 9801_ $$aFullTexts