000843635 001__ 843635
000843635 005__ 20210129232622.0
000843635 0247_ $$2doi$$a10.1016/j.nima.2018.01.040
000843635 0247_ $$2ISSN$$a0168-9002
000843635 0247_ $$2ISSN$$a1872-9576
000843635 0247_ $$2WOS$$aWOS:000425974100007
000843635 0247_ $$2altmetric$$aaltmetric:32666430
000843635 037__ $$aFZJ-2018-01213
000843635 082__ $$a530
000843635 1001_ $$0P:(DE-Juel1)159131$$aBerneking, Arne$$b0$$eCorresponding author
000843635 245__ $$aA new PET detector concept for compact preclinical high-resolution hybrid MR-PET
000843635 260__ $$aAmsterdam$$bNorth-Holland Publ. Co.$$c2018
000843635 3367_ $$2DRIVER$$aarticle
000843635 3367_ $$2DataCite$$aOutput Types/Journal article
000843635 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1518010714_8812
000843635 3367_ $$2BibTeX$$aARTICLE
000843635 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000843635 3367_ $$00$$2EndNote$$aJournal Article
000843635 520__ $$aThis work presents a new PET detector concept for compact preclinical hybrid MR-PET. The detector concept is based on Linearly-Graded SiPM produced with current FBK RGB-HD technology. One 7.75 mm x 7.75 mm large sensor chip is coupled with optical grease to a black coated 8 mm x 8 mm large and 3 mm thick monolithic LYSO crystal. The readout is obtained from four readout channels with the linear encoding based on integrated resistors and the Center of Gravity approach.To characterize the new detector concept, the spatial and energy resolutions were measured. Therefore, the measurement setup was prepared to radiate a collimated beam to 25 different points perpendicular to the monolithic scintillator crystal. Starting in the center point of the crystal at 0 mm / 0 mm and sampling a grid with a pitch of 1.75 mm, all significant points of the detector were covered by the collimator beam.The measured intrinsic spatial resolution (FWHM) was 0.74 +/- 0.01 mm in x- and 0.69 +/- 0.01 mm in the y-direction at the center of the detector. At the same point, the measured energy resolution (FWHM) was 13.01 +/- 0.05 %. The mean intrinsic spatial resolution (FWHM) over the whole detector was 0.80 +/- 0.28 mm in x- and 0.72 +/- 0.19 mm in y-direction. The energy resolution (FWHM) of the detector was between 13 and 17.3 % with an average energy resolution of 15.7 +/- 1.0 %. Due to the reduced thickness, the sensitivity of this gamma detector is low but still higher than pixelated designs with the same thickness due to the monolithic crystals. Combining compact design, high spatial resolution, and high sensitivity, the detector concept is particularly suitable for applications where the scanner bore size is limited and high resolution is required — as is the case in small animal hybrid MR-PET.
000843635 536__ $$0G:(DE-HGF)POF3-573$$a573 - Neuroimaging (POF3-573)$$cPOF3-573$$fPOF III$$x0
000843635 588__ $$aDataset connected to CrossRef
000843635 7001_ $$0P:(DE-HGF)0$$aGola, Alberto$$b1
000843635 7001_ $$0P:(DE-HGF)0$$aFerri, Alessandro$$b2
000843635 7001_ $$0P:(DE-Juel1)169335$$aFinster, Felix$$b3
000843635 7001_ $$0P:(DE-HGF)0$$aRucatti, Daniele$$b4
000843635 7001_ $$0P:(DE-HGF)0$$aPaternoster, Giovanni$$b5
000843635 7001_ $$0P:(DE-Juel1)131794$$aShah, N. J.$$b6$$ufzj
000843635 7001_ $$0P:(DE-HGF)0$$aPiemonte, Claudio$$b7
000843635 7001_ $$0P:(DE-Juel1)164254$$aLerche, Christoph$$b8$$ufzj
000843635 773__ $$0PERI:(DE-600)1466532-3$$a10.1016/j.nima.2018.01.040$$gVol. 888, p. 44 - 52$$p44 - 52$$tNuclear instruments & methods in physics research / A$$v888$$x0168-9002$$y2018
000843635 8564_ $$uhttps://juser.fz-juelich.de/record/843635/files/1-s2.0-S0168900218300573-main.pdf$$yRestricted
000843635 8564_ $$uhttps://juser.fz-juelich.de/record/843635/files/1-s2.0-S0168900218300573-main.gif?subformat=icon$$xicon$$yRestricted
000843635 8564_ $$uhttps://juser.fz-juelich.de/record/843635/files/1-s2.0-S0168900218300573-main.jpg?subformat=icon-1440$$xicon-1440$$yRestricted
000843635 8564_ $$uhttps://juser.fz-juelich.de/record/843635/files/1-s2.0-S0168900218300573-main.jpg?subformat=icon-180$$xicon-180$$yRestricted
000843635 8564_ $$uhttps://juser.fz-juelich.de/record/843635/files/1-s2.0-S0168900218300573-main.jpg?subformat=icon-640$$xicon-640$$yRestricted
000843635 8564_ $$uhttps://juser.fz-juelich.de/record/843635/files/1-s2.0-S0168900218300573-main.pdf?subformat=pdfa$$xpdfa$$yRestricted
000843635 909CO $$ooai:juser.fz-juelich.de:843635$$pVDB
000843635 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)131794$$aForschungszentrum Jülich$$b6$$kFZJ
000843635 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)164254$$aForschungszentrum Jülich$$b8$$kFZJ
000843635 9131_ $$0G:(DE-HGF)POF3-573$$1G:(DE-HGF)POF3-570$$2G:(DE-HGF)POF3-500$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bKey Technologies$$lDecoding the Human Brain$$vNeuroimaging$$x0
000843635 9141_ $$y2018
000843635 915__ $$0StatID:(DE-HGF)0420$$2StatID$$aNationallizenz
000843635 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bNUCL INSTRUM METH A : 2015
000843635 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS
000843635 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline
000843635 915__ $$0StatID:(DE-HGF)0310$$2StatID$$aDBCoverage$$bNCBI Molecular Biology Database
000843635 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search
000843635 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC
000843635 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bThomson Reuters Master Journal List
000843635 915__ $$0StatID:(DE-HGF)0110$$2StatID$$aWoS$$bScience Citation Index
000843635 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection
000843635 915__ $$0StatID:(DE-HGF)0111$$2StatID$$aWoS$$bScience Citation Index Expanded
000843635 915__ $$0StatID:(DE-HGF)1150$$2StatID$$aDBCoverage$$bCurrent Contents - Physical, Chemical and Earth Sciences
000843635 915__ $$0StatID:(DE-HGF)1160$$2StatID$$aDBCoverage$$bCurrent Contents - Engineering, Computing and Technology
000843635 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5
000843635 9201_ $$0I:(DE-Juel1)INM-4-20090406$$kINM-4$$lPhysik der Medizinischen Bildgebung$$x0
000843635 9201_ $$0I:(DE-82)080010_20140620$$kJARA-BRAIN$$lJARA-BRAIN$$x1
000843635 980__ $$ajournal
000843635 980__ $$aVDB
000843635 980__ $$aI:(DE-Juel1)INM-4-20090406
000843635 980__ $$aI:(DE-82)080010_20140620
000843635 980__ $$aUNRESTRICTED