001     845932
005     20240712113046.0
024 7 _ |a 10.1016/j.jpowsour.2018.03.065
|2 doi
024 7 _ |a WOS:000435055500019
|2 WOS
037 _ _ |a FZJ-2018-03130
041 _ _ |a English
082 _ _ |a 620
100 1 _ |a Pfrang, A.
|0 P:(DE-HGF)0
|b 0
245 _ _ |a Long-term cycling induced jelly roll deformation in commercial 18650 cells
260 _ _ |a New York, NY [u.a.]
|c 2018
|b Elsevier
336 7 _ |a article
|2 DRIVER
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1527056711_32309
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
520 _ _ |a The effects of extended charge/discharge cycling on the morphology of the jelly roll of commercial 18650 lithium-ion battery cells (Sanyo UR18650E) are shown and discussed. Using micro X-ray computed tomography combined with post-mortem analysis it is shown that the jelly roll exhibits significant deformations after charge/discharge cycling. This effect appears despite the presence of a solid inner pin, which had been suggested in literature as prohibitive for jelly roll deformation. The effect is related to an inhomogeneous architecture of the cells caused mainly by the cathode tab in the vicinity of which deformations were observed most often. While it is shown here that such deformations eventually lead to delamination of the otherwise rather stable cathode coating and cause a rapid capacity fade, jelly roll deformation has also been observed after more than 1700 equivalent full cycles on cells which show a typical, non-accelerated ageing behavior for this cell type. A correlation between occurrence of delamination and occurrence of deformation was clearly identified by combining post-mortem and computed tomography analysis. It is discussed, if the well-documented deformation is caused by thickness variations of the anode and cathode during charge/discharge cycles. Furthermore, an in-depth characterization of the cell design is documented.
536 _ _ |a 131 - Electrochemical Storage (POF3-131)
|0 G:(DE-HGF)POF3-131
|c POF3-131
|f POF III
|x 0
700 1 _ |a Kersys, A.
|0 P:(DE-HGF)0
|b 1
700 1 _ |a Kriston, A.
|0 P:(DE-HGF)0
|b 2
700 1 _ |a Sauer, Dirk Uwe
|0 P:(DE-Juel1)172625
|b 3
|u fzj
700 1 _ |a Rahe, Christiane
|0 P:(DE-Juel1)168327
|b 4
|u fzj
700 1 _ |a Käbitz, Stefan
|0 P:(DE-Juel1)166431
|b 5
700 1 _ |a Figgemeier, Egbert
|0 P:(DE-Juel1)165182
|b 6
|e Corresponding author
|u fzj
773 _ _ |a 10.1016/j.jpowsour.2018.03.065
|0 PERI:(DE-600)1491915-1
|p 168-175
|t Journal of power sources
|v 392
|y 2018
|x 0378-7753
856 4 _ |u https://juser.fz-juelich.de/record/845932/files/1-s2.0-S0378775318303100-main.pdf
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/845932/files/1-s2.0-S0378775318303100-main.gif?subformat=icon
|x icon
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/845932/files/1-s2.0-S0378775318303100-main.jpg?subformat=icon-1440
|x icon-1440
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/845932/files/1-s2.0-S0378775318303100-main.jpg?subformat=icon-180
|x icon-180
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/845932/files/1-s2.0-S0378775318303100-main.jpg?subformat=icon-640
|x icon-640
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/845932/files/1-s2.0-S0378775318303100-main.pdf?subformat=pdfa
|x pdfa
|y Restricted
909 C O |o oai:juser.fz-juelich.de:845932
|p VDB
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 3
|6 P:(DE-Juel1)172625
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 4
|6 P:(DE-Juel1)168327
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 6
|6 P:(DE-Juel1)165182
913 1 _ |a DE-HGF
|l Speicher und vernetzte Infrastrukturen
|1 G:(DE-HGF)POF3-130
|0 G:(DE-HGF)POF3-131
|2 G:(DE-HGF)POF3-100
|v Electrochemical Storage
|x 0
|4 G:(DE-HGF)POF
|3 G:(DE-HGF)POF3
|b Energie
914 1 _ |y 2018
915 _ _ |a JCR
|0 StatID:(DE-HGF)0100
|2 StatID
|b J POWER SOURCES : 2015
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0300
|2 StatID
|b Medline
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0310
|2 StatID
|b NCBI Molecular Biology Database
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0600
|2 StatID
|b Ebsco Academic Search
915 _ _ |a Peer Review
|0 StatID:(DE-HGF)0030
|2 StatID
|b ASC
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0199
|2 StatID
|b Thomson Reuters Master Journal List
915 _ _ |a WoS
|0 StatID:(DE-HGF)0110
|2 StatID
|b Science Citation Index
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0150
|2 StatID
|b Web of Science Core Collection
915 _ _ |a WoS
|0 StatID:(DE-HGF)0111
|2 StatID
|b Science Citation Index Expanded
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1150
|2 StatID
|b Current Contents - Physical, Chemical and Earth Sciences
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1160
|2 StatID
|b Current Contents - Engineering, Computing and Technology
915 _ _ |a IF >= 5
|0 StatID:(DE-HGF)9905
|2 StatID
|b J POWER SOURCES : 2015
920 _ _ |l yes
920 1 _ |0 I:(DE-Juel1)IEK-12-20141217
|k IEK-12
|l Helmholtz-Institut Münster Ionenleiter für Energiespeicher
|x 0
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a I:(DE-Juel1)IEK-12-20141217
980 _ _ |a UNRESTRICTED
981 _ _ |a I:(DE-Juel1)IMD-4-20141217


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21