000848042 001__ 848042
000848042 005__ 20240711101507.0
000848042 0247_ $$2doi$$a10.1016/j.ijhydene.2018.08.058
000848042 0247_ $$2ISSN$$a0360-3199
000848042 0247_ $$2ISSN$$a1879-3487
000848042 0247_ $$2WOS$$aWOS:000446949400042
000848042 037__ $$aFZJ-2018-03332
000848042 082__ $$a660
000848042 1001_ $$0P:(DE-Juel1)129863$$aJanssen, Holger$$b0$$eCorresponding author
000848042 245__ $$aDesign and Experimental Validation of a HT-PEFC Stack with Metallic BPP
000848042 260__ $$aNew York, NY [u.a.]$$bElsevier$$c2018
000848042 3367_ $$2DRIVER$$aarticle
000848042 3367_ $$2DataCite$$aOutput Types/Journal article
000848042 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1547476301_17711
000848042 3367_ $$2BibTeX$$aARTICLE
000848042 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000848042 3367_ $$00$$2EndNote$$aJournal Article
000848042 520__ $$aThis paper provides detailed insight into the design, construction, production and verification of a metallic bipolar plate for High Temperature Polymer Electrolyte Fuel Cell stacks. With a focusing on applications with power demands of 5–10 kW, the active cell area is set to a maximum of 100 cm2. The double-plate-concept allows for liquid cooling in the inner bipolar plate compartment. Due to the bipolar plate production by hydroforming of thin stainless steel foils the structure of the coolant compartment is dependent on the gas flow field design. To ensure proper cooling functionality a co-design is necessary. The flow field design, in conjunction with the flow configuration of the reactants (reformate, air) and coolant, considers the effects of hydrogen and oxygen depletion on current density distribution, as well as the temperature profile on carbon monoxide poisoning. These specifications are based on previously published results. For validation, a 5-cell stack with commercial Membrane Electrode Assemblies was operated at 160 °C and 0.2 A/cm2 and regularly interrupted for the polarization curve measurement. After 4700 h of continuous operation, the test was terminated due to a rapid voltage drop in one of the cells. In this paper, it is shown that novel metallic bipolar plates from thin metal sheets can be used for the long-term operation of High Temperature Polymer Electrolyte Fuel Cell stacks.
000848042 536__ $$0G:(DE-HGF)POF3-135$$a135 - Fuel Cells (POF3-135)$$cPOF3-135$$fPOF III$$x0
000848042 588__ $$aDataset connected to CrossRef
000848042 7001_ $$0P:(DE-HGF)0$$aEdelmann, Achim$$b1
000848042 7001_ $$0P:(DE-HGF)0$$aMildebrath, Thea$$b2
000848042 7001_ $$0P:(DE-HGF)0$$aMüller, Patrick$$b3
000848042 7001_ $$0P:(DE-Juel1)129883$$aLehnert, Werner$$b4
000848042 7001_ $$0P:(DE-Juel1)129928$$aStolten, Detlef$$b5
000848042 773__ $$0PERI:(DE-600)1484487-4$$a10.1016/j.ijhydene.2018.08.058$$gVol. 43, no. 39, p. 18488 - 18497$$n39$$p18488 - 18497$$tInternational journal of hydrogen energy$$v43$$x0360-3199$$y2018
000848042 8564_ $$uhttps://juser.fz-juelich.de/record/848042/files/1-s2.0-S0360319918325709-main.pdf$$yRestricted
000848042 8564_ $$uhttps://juser.fz-juelich.de/record/848042/files/1-s2.0-S0360319918325709-main.pdf?subformat=pdfa$$xpdfa$$yRestricted
000848042 909CO $$ooai:juser.fz-juelich.de:848042$$pVDB
000848042 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129863$$aForschungszentrum Jülich$$b0$$kFZJ
000848042 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129883$$aForschungszentrum Jülich$$b4$$kFZJ
000848042 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-Juel1)129883$$aRWTH Aachen$$b4$$kRWTH
000848042 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129928$$aForschungszentrum Jülich$$b5$$kFZJ
000848042 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-Juel1)129928$$aRWTH Aachen$$b5$$kRWTH
000848042 9131_ $$0G:(DE-HGF)POF3-135$$1G:(DE-HGF)POF3-130$$2G:(DE-HGF)POF3-100$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bEnergie$$lSpeicher und vernetzte Infrastrukturen$$vFuel Cells$$x0
000848042 9141_ $$y2018
000848042 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bINT J HYDROGEN ENERG : 2015
000848042 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS
000848042 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline
000848042 915__ $$0StatID:(DE-HGF)0310$$2StatID$$aDBCoverage$$bNCBI Molecular Biology Database
000848042 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search
000848042 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC
000848042 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bThomson Reuters Master Journal List
000848042 915__ $$0StatID:(DE-HGF)0110$$2StatID$$aWoS$$bScience Citation Index
000848042 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection
000848042 915__ $$0StatID:(DE-HGF)0111$$2StatID$$aWoS$$bScience Citation Index Expanded
000848042 915__ $$0StatID:(DE-HGF)1160$$2StatID$$aDBCoverage$$bCurrent Contents - Engineering, Computing and Technology
000848042 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5
000848042 920__ $$lyes
000848042 9201_ $$0I:(DE-Juel1)IEK-3-20101013$$kIEK-3$$lElektrochemische Verfahrenstechnik$$x0
000848042 980__ $$ajournal
000848042 980__ $$aVDB
000848042 980__ $$aI:(DE-Juel1)IEK-3-20101013
000848042 980__ $$aUNRESTRICTED
000848042 981__ $$aI:(DE-Juel1)ICE-2-20101013