001     851119
005     20240712113106.0
024 7 _ |a 10.1016/j.electacta.2017.06.125
|2 doi
024 7 _ |a 0013-4686
|2 ISSN
024 7 _ |a 1873-3859
|2 ISSN
024 7 _ |a WOS:000406942800115
|2 WOS
037 _ _ |a FZJ-2018-04821
082 _ _ |a 540
100 1 _ |a Mönnighoff, Xaver
|0 P:(DE-HGF)0
|b 0
245 _ _ |a Post-Mortem Investigations of Fluorinated Flame Retardants for Lithium Ion Battery Electrolytes by Gas Chromatography with Chemical Ionization
260 _ _ |a New York, NY [u.a.]
|c 2017
|b Elsevier
336 7 _ |a article
|2 DRIVER
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1534250970_1034
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
520 _ _ |a Using flame retardants (FRs) in lithium ion battery (LIB) electrolytes is usually a tradeoff between electrochemical performance and electrolyte flammability. Fluorinated FRs are a promising class of FRs which are currently under investigation. During this work, three FRs originating from triethyl phosphate with varying degree of fluorination were investigated regarding their electrochemical stability on cathode (LiNi0.33Co0.33Mn0.33O2, NCM) and anode (graphite) in half cells. During long-term cycling, changes in performance were observed. Especially on the anode side the FR addition showed a decrease in performance in comparison to the standard electrolyte (DEC/EC 1:1, 1M LiPF6). The electrolytes containing the three FRs were extracted from the cells and analyzed regarding their changes in composition and structural degradation. The decomposition products were investigated by gas chromatography (GC) with electron impact (EI) ionization and mass selective (MS) detection. To obtain more information with regard to the identification of unknown decomposition products further GC‐MS experiments with positive chemical ionization (PCI) and negative chemical ionization (NCI) were performed. Twelve different volatile organic decomposition products were identified. These decomposition products can be subdivided regarding their basic structure. Ether based, carbonate based and phosphate based fluorinated and non-fluorinated decomposition products were identified. Furthermore, possible formation pathways for all groups of decomposition products were postulated taking existing literature into account.
536 _ _ |a 131 - Electrochemical Storage (POF3-131)
|0 G:(DE-HGF)POF3-131
|c POF3-131
|f POF III
|x 0
588 _ _ |a Dataset connected to CrossRef
700 1 _ |a Murmann, Patrick
|0 P:(DE-HGF)0
|b 1
700 1 _ |a Weber, Waldemar
|0 P:(DE-HGF)0
|b 2
700 1 _ |a Winter, Martin
|0 P:(DE-Juel1)166130
|b 3
|u fzj
700 1 _ |a Nowak, Sascha
|0 P:(DE-HGF)0
|b 4
|e Corresponding author
773 _ _ |a 10.1016/j.electacta.2017.06.125
|g Vol. 246, p. 1042 - 1051
|0 PERI:(DE-600)1483548-4
|p 1042 - 1051
|t Electrochimica acta
|v 246
|y 2017
|x 0013-4686
856 4 _ |u https://juser.fz-juelich.de/record/851119/files/1-s2.0-S0013468617313634-main.pdf
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/851119/files/1-s2.0-S0013468617313634-main.gif?subformat=icon
|x icon
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/851119/files/1-s2.0-S0013468617313634-main.jpg?subformat=icon-1440
|x icon-1440
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/851119/files/1-s2.0-S0013468617313634-main.jpg?subformat=icon-180
|x icon-180
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/851119/files/1-s2.0-S0013468617313634-main.jpg?subformat=icon-640
|x icon-640
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/851119/files/1-s2.0-S0013468617313634-main.pdf?subformat=pdfa
|x pdfa
|y Restricted
909 C O |o oai:juser.fz-juelich.de:851119
|p VDB
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 3
|6 P:(DE-Juel1)166130
913 1 _ |a DE-HGF
|l Speicher und vernetzte Infrastrukturen
|1 G:(DE-HGF)POF3-130
|0 G:(DE-HGF)POF3-131
|2 G:(DE-HGF)POF3-100
|v Electrochemical Storage
|x 0
|4 G:(DE-HGF)POF
|3 G:(DE-HGF)POF3
|b Energie
914 1 _ |y 2018
915 _ _ |a Nationallizenz
|0 StatID:(DE-HGF)0420
|2 StatID
915 _ _ |a JCR
|0 StatID:(DE-HGF)0100
|2 StatID
|b ELECTROCHIM ACTA : 2015
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0300
|2 StatID
|b Medline
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0310
|2 StatID
|b NCBI Molecular Biology Database
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0600
|2 StatID
|b Ebsco Academic Search
915 _ _ |a Peer Review
|0 StatID:(DE-HGF)0030
|2 StatID
|b ASC
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0199
|2 StatID
|b Thomson Reuters Master Journal List
915 _ _ |a WoS
|0 StatID:(DE-HGF)0110
|2 StatID
|b Science Citation Index
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0150
|2 StatID
|b Web of Science Core Collection
915 _ _ |a WoS
|0 StatID:(DE-HGF)0111
|2 StatID
|b Science Citation Index Expanded
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1150
|2 StatID
|b Current Contents - Physical, Chemical and Earth Sciences
915 _ _ |a IF < 5
|0 StatID:(DE-HGF)9900
|2 StatID
920 1 _ |0 I:(DE-Juel1)IEK-12-20141217
|k IEK-12
|l Helmholtz-Institut Münster Ionenleiter für Energiespeicher
|x 0
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a I:(DE-Juel1)IEK-12-20141217
980 _ _ |a UNRESTRICTED
981 _ _ |a I:(DE-Juel1)IMD-4-20141217


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21