@INPROCEEDINGS{Han:859078,
      author       = {Han, Qinghua and Gao, Anran and Narimani, Keyvan and Wang,
                      Yuelin and Li, Tie and Mantl, Siegfried and Zhao, Qing-Tai},
      title        = {{U}ltrathin lateral unidirectional bipolar-type
                      insulated-gate transistor as p{H} sensor},
      publisher    = {IEEE},
      reportid     = {FZJ-2019-00029},
      pages        = {268-271},
      year         = {2017},
      comment      = {2017 47th European Solid-State Device Research Conference
                      (ESSDERC) : [Proceedings] - IEEE, 2017. - ISBN
                      978-1-5090-5978-2},
      booktitle     = {2017 47th European Solid-State Device
                       Research Conference (ESSDERC) :
                       [Proceedings] - IEEE, 2017. - ISBN
                       978-1-5090-5978-2},
      abstract     = {Here, the utilizing of lateral unidirectional bipolar-type
                      insulated-gate transistors (Lubistors) for pH detection was
                      demonstrated for the first time. The high on current and
                      ambipolarity of Lubistors are favorable properties for
                      reliable sensing application. The ultrathin Lubistors were
                      fabricated on 20-nm-thick SOI substrates in planar geometry.
                      The triode-like current-voltage characteristic and excellent
                      gate modulation property for Lubistor were demonstrated.
                      Without any surface modification, this Lubistor based pH
                      sensor was capable of detecting the change of hydrogen ion
                      concentration by the corresponding change in anode current.
                      The anode current revealed nonlinear pH-dependence and
                      complementary change at different working regions. The
                      Lubistor sensor showed stable, reversible and reproducible
                      pH sensing performance. The proposed Lubistor based sensor
                      holds great potential for high reliable biological species
                      detection.},
      month         = {Sep},
      date          = {2017-09-11},
      organization  = {ESSDERC 2017 - 47th IEEE European
                       Solid-State Device Research Conference
                       (ESSDERC), Leuven (Belgium), 11 Sep
                       2017 - 14 Sep 2017},
      cin          = {PGI-9},
      cid          = {I:(DE-Juel1)PGI-9-20110106},
      pnm          = {521 - Controlling Electron Charge-Based Phenomena
                      (POF3-521)},
      pid          = {G:(DE-HGF)POF3-521},
      typ          = {PUB:(DE-HGF)8 / PUB:(DE-HGF)7},
      doi          = {10.1109/ESSDERC.2017.8066643},
      url          = {https://juser.fz-juelich.de/record/859078},
}