000860627 001__ 860627
000860627 005__ 20240711113524.0
000860627 0247_ $$2doi$$a10.1016/j.fusengdes.2018.08.014
000860627 0247_ $$2ISSN$$a0920-3796
000860627 0247_ $$2ISSN$$a1873-7196
000860627 0247_ $$2WOS$$aWOS:000454466000015
000860627 037__ $$aFZJ-2019-01300
000860627 082__ $$a530
000860627 1001_ $$00000-0001-7061-1577$$aQu, Shilian$$b0
000860627 245__ $$aDegradation of thermal conductivity of the damaged layer of tungsten irradiated by helium-plasma
000860627 260__ $$aNew York, NY [u.a.]$$bElsevier$$c2018
000860627 3367_ $$2DRIVER$$aarticle
000860627 3367_ $$2DataCite$$aOutput Types/Journal article
000860627 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1549553906_17337
000860627 3367_ $$2BibTeX$$aARTICLE
000860627 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000860627 3367_ $$00$$2EndNote$$aJournal Article
000860627 520__ $$aPure tungsten samples were irradiated by helium plasma in the linear plasma device PSI-2 with an ion energy of 40 eV and a flux of 1.1 × 1022 m−2s−1. The irradiation temperature was from 523 K to 773 K and the fluence was from 1.0 × 1025 to 1.0 × 1026 m−2. A damaged layer of 10 nm thickness was formed on the sample surface with a destroyed crystalline structure. Helium-bubbles and surface modification in nanoscale were observed. Thermal conductivities of the ultra-thin damaged layers were measured by the transient thermoreflectance technique. Result shows that the thermal conductivity reduced two orders of magnitude compared to the bulk value and decreased with increasing irradiation temperature and fluence. Moreover, the helium-irradiated samples were exposed to ELM-like heat load produced by electron beam on EMS-60. The pulse length was 1 ms and each sample was exposed to 5 pulses. Melting occurred under power density of 1.7 GW m−2. As the thermal conductivity of the damaged layer decreased, the molten bath of the irradiated sample deepened. The degraded thermal conductivity led to a lower melting threshold. The characterization of the thermal conductivity of the damaged layer induced by the plasma irradiation is a promising way to estimate the damage level, as well as the failure threshold, of the plasma facing components.
000860627 536__ $$0G:(DE-HGF)POF3-113$$a113 - Methods and Concepts for Material Development (POF3-113)$$cPOF3-113$$fPOF III$$x0
000860627 588__ $$aDataset connected to CrossRef
000860627 7001_ $$0P:(DE-HGF)0$$aSun, Hao$$b1
000860627 7001_ $$0P:(DE-Juel1)130070$$aKreter, Arkadi$$b2
000860627 7001_ $$0P:(DE-Juel1)166383$$aYuan, Yue$$b3
000860627 7001_ $$0P:(DE-HGF)0$$aCheng, Long$$b4
000860627 7001_ $$00000-0003-2014-1225$$aHuang, Zhengxing$$b5
000860627 7001_ $$0P:(DE-HGF)0$$aXu, Ben$$b6
000860627 7001_ $$0P:(DE-HGF)0$$aChen, Wanqi$$b7
000860627 7001_ $$0P:(DE-HGF)0$$aCui, Wei$$b8
000860627 7001_ $$0P:(DE-HGF)0$$aTang, Zhenan$$b9
000860627 7001_ $$0P:(DE-HGF)0$$aJia, Yuzhen$$b10
000860627 7001_ $$0P:(DE-HGF)0$$aLian, YouYun$$b11
000860627 7001_ $$0P:(DE-HGF)0$$aLiu, Xiang$$b12
000860627 7001_ $$0P:(DE-HGF)0$$aLiu, Wei$$b13$$eCorresponding author
000860627 773__ $$0PERI:(DE-600)1492280-0$$a10.1016/j.fusengdes.2018.08.014$$gVol. 137, p. 97 - 103$$p97 - 103$$tFusion engineering and design$$v137$$x0920-3796$$y2018
000860627 8564_ $$uhttps://juser.fz-juelich.de/record/860627/files/1-s2.0-S0920379618306045-main.pdf$$yRestricted
000860627 8564_ $$uhttps://juser.fz-juelich.de/record/860627/files/1-s2.0-S0920379618306045-main.pdf?subformat=pdfa$$xpdfa$$yRestricted
000860627 909CO $$ooai:juser.fz-juelich.de:860627$$pVDB
000860627 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)130070$$aForschungszentrum Jülich$$b2$$kFZJ
000860627 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-HGF)0$$aForschungszentrum Jülich$$b13$$kFZJ
000860627 9131_ $$0G:(DE-HGF)POF3-113$$1G:(DE-HGF)POF3-110$$2G:(DE-HGF)POF3-100$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bEnergie$$lEnergieeffizienz, Materialien und Ressourcen$$vMethods and Concepts for Material Development$$x0
000860627 9141_ $$y2019
000860627 915__ $$0StatID:(DE-HGF)0420$$2StatID$$aNationallizenz
000860627 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bFUSION ENG DES : 2017
000860627 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS
000860627 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search
000860627 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC
000860627 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List
000860627 915__ $$0StatID:(DE-HGF)0110$$2StatID$$aWoS$$bScience Citation Index
000860627 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection
000860627 915__ $$0StatID:(DE-HGF)0111$$2StatID$$aWoS$$bScience Citation Index Expanded
000860627 915__ $$0StatID:(DE-HGF)1160$$2StatID$$aDBCoverage$$bCurrent Contents - Engineering, Computing and Technology
000860627 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5
000860627 9201_ $$0I:(DE-Juel1)IEK-4-20101013$$kIEK-4$$lPlasmaphysik$$x0
000860627 980__ $$ajournal
000860627 980__ $$aVDB
000860627 980__ $$aI:(DE-Juel1)IEK-4-20101013
000860627 980__ $$aUNRESTRICTED
000860627 981__ $$aI:(DE-Juel1)IFN-1-20101013