% IMPORTANT: The following is UTF-8 encoded. This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.
@ARTICLE{DREWS:861466,
author = {DREWS, P. and NIEMANN, H. and COSFELD, J. and GAO, Y. and
GEIGER, J. and GRULKE, O. and HENKEL, M. and HÖSCHEN, D.
and HOLLFELD, K. and KILLER, C. and KRÄMER-FLECKEN, A. and
LIANG, Y. and LIU, S. and NICOLAI, D. and NEUBAUER, O. and
RACK, M. and SCHWEER, B. and SATHEESWARAN, G. and
RUDISCHHAUSER, L. and SANDRI, N. and WANG, N.},
title = {{M}agnetic configuration effects on the edge heat flux in
the limiter plasma on {W}7-{X} measured using the infrared
camera and the combined probe},
journal = {Plasma science $\&$ technology},
volume = {20},
number = {5},
issn = {1009-0630},
address = {Bristol},
publisher = {IOP},
reportid = {FZJ-2019-01931},
pages = {054003 -},
year = {2018},
abstract = {Controlling the heat and particle fluxes in the plasma edge
and on the plasma facing components is important for the
safe and effective operation of every magnetically confined
fusion device. This was attempted on Wendelstein 7-X in the
first operational campaign, with the modification of the
magnetic configuration by use of the trim coils and tuning
the field coil currents, commonly named iota scan. Ideally,
the heat loads on the five limiters are equal. However, they
differ between each limiter and are non-uniform, due to the
(relatively small) error fields caused by the misalignment
of components. It is therefore necessary to study the
influence of the configuration changes on the transport of
heat and particles in the plasma edge caused by the
application of error fields and the change of the magnetic
configuration. In this paper the up-stream measurements
conducted with the combined probe are compared to the
downstream measurements with the DIAS infrared camera on the
limiter.},
cin = {IEK-4 / ZEA-1 / JARA-HPC},
ddc = {530},
cid = {I:(DE-Juel1)IEK-4-20101013 / I:(DE-Juel1)ZEA-1-20090406 /
$I:(DE-82)080012_20140620$},
pnm = {174 - Plasma-Wall-Interaction (POF3-174) / Predictive
EMC3-EIRENE modelling and diagnostic interpretation for
Wendelstein 7-X and EAST $(jiek42_20180501)$},
pid = {G:(DE-HGF)POF3-174 / $G:(DE-Juel1)jiek42_20180501$},
typ = {PUB:(DE-HGF)16},
UT = {WOS:000431134200003},
doi = {10.1088/2058-6272/aaa968},
url = {https://juser.fz-juelich.de/record/861466},
}