% IMPORTANT: The following is UTF-8 encoded.  This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.

@ARTICLE{DREWS:861466,
      author       = {DREWS, P. and NIEMANN, H. and COSFELD, J. and GAO, Y. and
                      GEIGER, J. and GRULKE, O. and HENKEL, M. and HÖSCHEN, D.
                      and HOLLFELD, K. and KILLER, C. and KRÄMER-FLECKEN, A. and
                      LIANG, Y. and LIU, S. and NICOLAI, D. and NEUBAUER, O. and
                      RACK, M. and SCHWEER, B. and SATHEESWARAN, G. and
                      RUDISCHHAUSER, L. and SANDRI, N. and WANG, N.},
      title        = {{M}agnetic configuration effects on the edge heat flux in
                      the limiter plasma on {W}7-{X} measured using the infrared
                      camera and the combined probe},
      journal      = {Plasma science $\&$ technology},
      volume       = {20},
      number       = {5},
      issn         = {1009-0630},
      address      = {Bristol},
      publisher    = {IOP},
      reportid     = {FZJ-2019-01931},
      pages        = {054003 -},
      year         = {2018},
      abstract     = {Controlling the heat and particle fluxes in the plasma edge
                      and on the plasma facing components is important for the
                      safe and effective operation of every magnetically confined
                      fusion device. This was attempted on Wendelstein 7-X in the
                      first operational campaign, with the modification of the
                      magnetic configuration by use of the trim coils and tuning
                      the field coil currents, commonly named iota scan. Ideally,
                      the heat loads on the five limiters are equal. However, they
                      differ between each limiter and are non-uniform, due to the
                      (relatively small) error fields caused by the misalignment
                      of components. It is therefore necessary to study the
                      influence of the configuration changes on the transport of
                      heat and particles in the plasma edge caused by the
                      application of error fields and the change of the magnetic
                      configuration. In this paper the up-stream measurements
                      conducted with the combined probe are compared to the
                      downstream measurements with the DIAS infrared camera on the
                      limiter.},
      cin          = {IEK-4 / ZEA-1 / JARA-HPC},
      ddc          = {530},
      cid          = {I:(DE-Juel1)IEK-4-20101013 / I:(DE-Juel1)ZEA-1-20090406 /
                      $I:(DE-82)080012_20140620$},
      pnm          = {174 - Plasma-Wall-Interaction (POF3-174) / Predictive
                      EMC3-EIRENE modelling and diagnostic interpretation for
                      Wendelstein 7-X and EAST $(jiek42_20180501)$},
      pid          = {G:(DE-HGF)POF3-174 / $G:(DE-Juel1)jiek42_20180501$},
      typ          = {PUB:(DE-HGF)16},
      UT           = {WOS:000431134200003},
      doi          = {10.1088/2058-6272/aaa968},
      url          = {https://juser.fz-juelich.de/record/861466},
}