000861560 001__ 861560
000861560 005__ 20210130000850.0
000861560 0247_ $$2doi$$a10.1063/1.5030489
000861560 0247_ $$2ISSN$$a0003-6951
000861560 0247_ $$2ISSN$$a1077-3118
000861560 0247_ $$2ISSN$$a1520-8842
000861560 0247_ $$2ISSN$$a1931-9401
000861560 0247_ $$2Handle$$a2128/21889
000861560 0247_ $$2WOS$$aWOS:000435987400035
000861560 0247_ $$2altmetric$$aaltmetric:34697226
000861560 037__ $$aFZJ-2019-02011
000861560 082__ $$a530
000861560 1001_ $$00000-0001-8553-3604$$aForoughi, F.$$b0
000861560 245__ $$aA micro-SQUID with dispersive readout for magnetic scanning microscopy
000861560 260__ $$aNew York, NY$$bAIP74335$$c2018
000861560 3367_ $$2DRIVER$$aarticle
000861560 3367_ $$2DataCite$$aOutput Types/Journal article
000861560 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1573560156_30342
000861560 3367_ $$2BibTeX$$aARTICLE
000861560 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000861560 3367_ $$00$$2EndNote$$aJournal Article
000861560 520__ $$aWe have designed and characterized a micro-SQUID with dispersive readout for use in low temperature scanning probe microscopy systems. The design features a capacitively shunted RF SQUID with a tunable resonance frequency from 5 to 12 GHz, micrometer spatial resolution, and integrated superconducting coils for local application of magnetic fields. The SQUID is operated as a nonlinear oscillator with a flux- and power-dependent resonance frequency. Measurements for device characterization and noise benchmarking were carried out at 4 K. The measured flux noise above 10 kHz at 4 K is 80 nΦ0 Hz−1∕2 at a bandwidth of 200 MHz. Estimations suggest that one can benefit from parametric gain based on inherent nonlinearity of the Josephson junction and reduce the flux noise to 30 nΦ0Hz–1∕2 at 100 mK, which corresponds to 10.6 μBHz–1∕2 for a magnetic moment located at the center of the pickup loop.Measuring the magnetic response of mesoscopic samples or mapping it vs. position for extended systems is effective methods for revealing the fundamental quantum properties of condensed matter systems. Over the past few decades, many advanced magnetic imaging schemes have been developed, including magnetic force microscopy,1 scanning Hall probe microscopy,2 superconducting interference devices (SQUIDs),3,4 and NV center based magnetometry.5 The high sensitivity, low back action, and low power dissipation of SQUIDs make them attractive for many types of low temperature experiments. One classic example is the central role of scanning SQUID microscopy in tests of pairing symmetry of high-Tc cuprate superconductors.6 Other prominent applications are the thermodynamic characteristics of persistent currents in normal metal rings7 and proof of edge states in topological insulators in the quantum spin Hall regime.8A key performance for a SQUID is its flux sensitivity. Parametric amplification has been harnessed in nano-SQUIDs based on aluminum junctions9,10 in order to reduce the flux noise down to 30 nΦ0Hz–1∕2 with a bandwidth exceeding 60 MHz.10 Recent studies on parametric amplifiers and dispersive readout of superconducting qubits also harness the nonlinearity of the Josephson junction to boost sensitivity.11–13In scanning SQUID microscopy, signal sources often behave dipole-like, such as superconducting vortices in mesoscopic dots or currents in mesoscopic rings. Smaller SQUIDs provide better coupling to smaller samples which leads to higher spin sensitivity3,14 as the magnetic field of a dipole decreases with 1/r3. Various approaches have been pursued to reduce the size. The smallest nano-SQUID to date has been fabricated by evaporating Nb or Pb15 onto the apex of a sharp quartz tip reaching a loop diameter of below nm and a spin sensitivity of 0.38 μBHz−1/2 at tens of kHz bandwidth. Compared to such size-optimized devices, micro-SQUIDs fabricated using a standard Nb technique have the advantage of on-chip field coils and modulation coils,14 and can be operated at 4 K allowing for a wide range of applications. However, these come at the cost of larger pick-up loops of a few microns and a resulting poorer spin sensitivity of 200 μBHz−1/2 for a magnetic moment located at the center of the pickup loop.The limitation of large pickup loops was previously only overcome by devices with pickup loops defined by the focused-ion-beam,16 but has recently also been achieved by improvements in lithography and shown to offer better spatial resolution as well.17 Here, we present a scanning micro-SQUID which is based on the same fabrication technology incorporating another major advancement. Our design exploits the parametric amplification based on nonlinearities of the SQUID to boost sensitivity. The combination of a smaller pickup loop and parametric amplification of the signal leads to better spin sensitivity (10.6 μBHz−1/2) and higher bandwidth (200 MHz) compared to traditional DC micro-SQUIDs in which the flux sensitivity is mainly limited by internal dissipation.Our devices were fabricated at Hypres Inc. using planarized Nb/AlOx/Nb trilayer Josephson junction technology, including two planarized Nb layers with approximately 0.8 μm minimum feature size. The SQUID consists of a superconducting ring shunted by one Josephson junction with a designed critical current of 20 μA [Fig. 1(a)]. With this geometry, the SQUID is gradiometric, i.e., the effect of any homogeneous background magnetic field approximately cancels out. The smallest pickup loops implemented have an inner (outer) diameter of 1 μm (2 μm). The superconducting loop is shunted by an on-chip parallel-plate capacitor with amorphous silicon dioxide as dielectric which was designed to have a capacitance of 80 pF. The superconducting loop and the capacitor form a resonator with a flux dependent resonance frequency from 5 to 12 GHz. The pickup loops are placed on opposite corners of the parallel-plate capacitor at a distance of about 450 μm so that one loop can be located in close proximity to the sample while the other is kept far away from it. External fields can be applied to the sample by local single-turn field coils situated around each pickup loop. The field coils are fully integrated into the chip layout and can also be used to bias the SQUID at its most sensitive point. Compared to using additional modulation coils,14 this approach has the advantage of reducing the total device inductance, which leads to a higher sensitivity.18 In a scanning microscope, the field coil at the rear end (away from the sample) can be used to bias the SQUID or operate it in flux feedback such that resulting stray fields will not act on the sample, apart from a weak screening current through the pickup loop. The effective diameter of each coil is 7.5 μm, resulting in a mutual inductance of about 0.34 Φ0/mA (for the smallest pickup loop). The SQUID resonator is connected by an on-chip Z0 = 50 Ω coplanar waveguide (CPW) transmission line to the bonding pads. The two field coils are connected by two smaller CPWs to the bottom edge bonding pads [Fig. 1(c)], ending in two parallel-stripline waveguides running alongside the edges of the capacitor towards the respective field coils. Based on estimations, it should thus be possible to apply high frequency signals of at least several GHz to SQUID and sample.
000861560 536__ $$0G:(DE-HGF)POF3-144$$a144 - Controlling Collective States (POF3-144)$$cPOF3-144$$fPOF III$$x0
000861560 588__ $$aDataset connected to CrossRef
000861560 7001_ $$0P:(DE-HGF)0$$aMol, J.-M.$$b1
000861560 7001_ $$0P:(DE-HGF)0$$aMüller, T.$$b2
000861560 7001_ $$00000-0002-2581-3935$$aKirtley, J. R.$$b3
000861560 7001_ $$0P:(DE-HGF)0$$aMoler, K. A.$$b4
000861560 7001_ $$0P:(DE-Juel1)172019$$aBluhm, Hendrik$$b5$$eCorresponding author
000861560 773__ $$0PERI:(DE-600)2265524-4$$a10.1063/1.5030489$$gVol. 112, no. 25, p. 252601 -$$n25$$p252601 -$$tApplied physics reviews$$v112$$x1077-3118$$y2018
000861560 8564_ $$uhttps://juser.fz-juelich.de/record/861560/files/1.5030489.pdf$$yPublished on 2018-06-20. Available in OpenAccess from 2019-06-20.
000861560 8564_ $$uhttps://juser.fz-juelich.de/record/861560/files/1.5030489.pdf?subformat=pdfa$$xpdfa$$yPublished on 2018-06-20. Available in OpenAccess from 2019-06-20.
000861560 909CO $$ooai:juser.fz-juelich.de:861560$$pdnbdelivery$$pdriver$$pVDB$$popen_access$$popenaire
000861560 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)172019$$aForschungszentrum Jülich$$b5$$kFZJ
000861560 9131_ $$0G:(DE-HGF)POF3-144$$1G:(DE-HGF)POF3-140$$2G:(DE-HGF)POF3-100$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bEnergie$$lFuture Information Technology - Fundamentals, Novel Concepts and Energy Efficiency (FIT)$$vControlling Collective States$$x0
000861560 9141_ $$y2019
000861560 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS
000861560 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search
000861560 915__ $$0StatID:(DE-HGF)0530$$2StatID$$aEmbargoed OpenAccess
000861560 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bAPPL PHYS REV : 2017
000861560 915__ $$0StatID:(DE-HGF)9910$$2StatID$$aIF >= 10$$bAPPL PHYS REV : 2017
000861560 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection
000861560 915__ $$0StatID:(DE-HGF)0110$$2StatID$$aWoS$$bScience Citation Index
000861560 915__ $$0StatID:(DE-HGF)0111$$2StatID$$aWoS$$bScience Citation Index Expanded
000861560 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5
000861560 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC
000861560 915__ $$0StatID:(DE-HGF)1150$$2StatID$$aDBCoverage$$bCurrent Contents - Physical, Chemical and Earth Sciences
000861560 915__ $$0StatID:(DE-HGF)0430$$2StatID$$aNational-Konsortium
000861560 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline
000861560 915__ $$0StatID:(DE-HGF)0320$$2StatID$$aDBCoverage$$bPubMed Central
000861560 915__ $$0StatID:(DE-HGF)0420$$2StatID$$aNationallizenz
000861560 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List
000861560 920__ $$lyes
000861560 9201_ $$0I:(DE-Juel1)PGI-11-20170113$$kPGI-11$$lJARA Institut Quanteninformation$$x0
000861560 9201_ $$0I:(DE-82)080009_20140620$$kJARA-FIT$$lJARA-FIT$$x1
000861560 980__ $$ajournal
000861560 980__ $$aVDB
000861560 980__ $$aI:(DE-Juel1)PGI-11-20170113
000861560 980__ $$aI:(DE-82)080009_20140620
000861560 980__ $$aUNRESTRICTED
000861560 9801_ $$aFullTexts