001     863475
005     20210130002131.0
024 7 _ |a 10.1002/mrm.27796
|2 doi
024 7 _ |a 0740-3194
|2 ISSN
024 7 _ |a 1522-2594
|2 ISSN
024 7 _ |a pmid:31241224
|2 pmid
024 7 _ |a WOS:000483917000019
|2 WOS
024 7 _ |a altmetric:63824746
|2 altmetric
037 _ _ |a FZJ-2019-03529
082 _ _ |a 610
100 1 _ |a Buschbeck, Richard P.
|0 P:(DE-Juel1)168245
|b 0
245 _ _ |a 3D rigid-body motion information from spherical Lissajous navigators at small k-space radii: A proof of concept
260 _ _ |a New York, NY [u.a.]
|c 2019
|b Wiley-Liss
336 7 _ |a article
|2 DRIVER
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1563200247_12078
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
520 _ _ |a PurposeTo demonstrate, for the first time, the feasibility of obtaining low‐latency 3D rigid‐body motion information from spherical Lissajous navigators acquired at extremely small k‐space radii, which has significant advantages compared with previous techniques.Theory and MethodsA spherical navigator concept is proposed in which the surface of a k‐space sphere is sampled on a 3D Lissajous curve at a radius of 0.1/cm. The navigator only uses a single excitation and is acquired in less than 5 ms. Rotation estimations were calculated with an algorithm from computer vision that exploits a rotation theorem of the spherical harmonics transform and has minimal computational cost. The effectiveness of the concept was investigated with phantom and in vivo measurements on a commercial 3T MRI scanner.ResultsScanner‐induced in vivo motion was measured with maximum absolute errors of 0.58° and 0.33 mm for rotations and translations, respectively. In the case of real, in vivo motion, the proposed method showed good agreement with motion information from FSL image registrations (mean/maximum deviations of 0.37°/1.24° and 0.44 mm/1.35 mm). In addition, phantom measurements indicated precisions of 0.014° and 0.013 mm. The computations for complete motion information took, on average, 24 ms on an ordinary laptop.
536 _ _ |a 573 - Neuroimaging (POF3-573)
|0 G:(DE-HGF)POF3-573
|c POF3-573
|f POF III
|x 0
588 _ _ |a Dataset connected to CrossRef
700 1 _ |a Yun, Seong Dae
|0 P:(DE-Juel1)141899
|b 1
|u fzj
700 1 _ |a Shah, N. J.
|0 P:(DE-Juel1)131794
|b 2
|e Corresponding author
|u fzj
773 _ _ |a 10.1002/mrm.27796
|0 PERI:(DE-600)1493786-4
|n 4
|p 1462-1470
|t Magnetic resonance in medicine
|v 84
|y 2019
|x 0740-3194
856 4 _ |u https://juser.fz-juelich.de/record/863475/files/Buschbeck_et_al-2019-Magnetic_Resonance_in_Medicine.pdf
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/863475/files/Buschbeck_et_al-2019-Magnetic_Resonance_in_Medicine.pdf?subformat=pdfa
|x pdfa
|y Restricted
909 C O |o oai:juser.fz-juelich.de:863475
|p VDB
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 0
|6 P:(DE-Juel1)168245
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 1
|6 P:(DE-Juel1)141899
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 2
|6 P:(DE-Juel1)131794
913 1 _ |a DE-HGF
|b Key Technologies
|l Decoding the Human Brain
|1 G:(DE-HGF)POF3-570
|0 G:(DE-HGF)POF3-573
|2 G:(DE-HGF)POF3-500
|v Neuroimaging
|x 0
|4 G:(DE-HGF)POF
|3 G:(DE-HGF)POF3
914 1 _ |y 2019
915 _ _ |a Nationallizenz
|0 StatID:(DE-HGF)0420
|2 StatID
915 _ _ |a JCR
|0 StatID:(DE-HGF)0100
|2 StatID
|b MAGN RESON MED : 2017
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0300
|2 StatID
|b Medline
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0199
|2 StatID
|b Clarivate Analytics Master Journal List
915 _ _ |a WoS
|0 StatID:(DE-HGF)0110
|2 StatID
|b Science Citation Index
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0150
|2 StatID
|b Web of Science Core Collection
915 _ _ |a WoS
|0 StatID:(DE-HGF)0111
|2 StatID
|b Science Citation Index Expanded
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1110
|2 StatID
|b Current Contents - Clinical Medicine
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1030
|2 StatID
|b Current Contents - Life Sciences
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1050
|2 StatID
|b BIOSIS Previews
915 _ _ |a IF < 5
|0 StatID:(DE-HGF)9900
|2 StatID
920 1 _ |0 I:(DE-Juel1)INM-4-20090406
|k INM-4
|l Physik der Medizinischen Bildgebung
|x 0
920 1 _ |0 I:(DE-Juel1)INM-11-20170113
|k INM-11
|l Jara-Institut Quantum Information
|x 1
920 1 _ |0 I:(DE-82)080010_20140620
|k JARA-BRAIN
|l JARA-BRAIN
|x 2
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a I:(DE-Juel1)INM-4-20090406
980 _ _ |a I:(DE-Juel1)INM-11-20170113
980 _ _ |a I:(DE-82)080010_20140620
980 _ _ |a UNRESTRICTED


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21