000864097 001__ 864097
000864097 005__ 20240709094448.0
000864097 0247_ $$2doi$$a10.1016/j.ijfatigue.2019.06.030
000864097 0247_ $$2ISSN$$a0142-1123
000864097 0247_ $$2ISSN$$a1879-3452
000864097 0247_ $$2WOS$$aWOS:000482492600043
000864097 0247_ $$2Handle$$a2128/24798
000864097 037__ $$aFZJ-2019-04000
000864097 082__ $$a600
000864097 1001_ $$0P:(DE-Juel1)161596$$aFischer, T.$$b0$$eCorresponding author$$ufzj
000864097 245__ $$aNew Insights Into the Threshold Behavior of a 9–12% Cr Ferritic/Martensitic Steel – Separation and Quantification of Crack Closure Mechanisms
000864097 260__ $$aOxford$$bElsevier$$c2019
000864097 3367_ $$2DRIVER$$aarticle
000864097 3367_ $$2DataCite$$aOutput Types/Journal article
000864097 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1564131503_7548
000864097 3367_ $$2BibTeX$$aARTICLE
000864097 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000864097 3367_ $$00$$2EndNote$$aJournal Article
000864097 520__ $$aThe energy transition and the associated increase in the share of regenerative energies require flexible power plant operation to compensate fluctuations in residual load. As a result of the decreasing dwell times at constant high temperatures, the significance of fatigue damage gains in importance. At present, existing design codes are of limited validity for this new loading scenario. This necessitates the development of adapted design codes based on damage tolerance concepts. For this reason the frequency dependent threshold behavior of the ferritic/martensitic steel X20CrMoV12-1 was investigated in a temperature range from 300 °C to 600 °C. In order to exploit the maximum lifetime of a component without compromising safety, detailed knowledge on active crack closing mechanisms is of elementary importance. Therefore, a general experimental approach for separation and quantification of crack closure mechanisms and their impact on crack propagation threshold values was developed. By this methodology, both the influence of temperature and corrosion on the threshold can be separated and quantified despite superposition of several mechanisms. The only application criterion of this procedure is SR ≪ 1, because roughness induced crack closure has to be negligible small. If roughness induced crack closure cannot be neglected, the methodology developed in this study has to be modified by models which quantify the influence of roughness induced crack closure.
000864097 536__ $$0G:(DE-HGF)POF3-113$$a113 - Methods and Concepts for Material Development (POF3-113)$$cPOF3-113$$fPOF III$$x0
000864097 588__ $$aDataset connected to CrossRef
000864097 7001_ $$0P:(DE-Juel1)129742$$aKuhn, B.$$b1$$ufzj
000864097 773__ $$0PERI:(DE-600)2013377-7$$a10.1016/j.ijfatigue.2019.06.030$$gVol. 127, p. 479 - 487$$p479 - 487$$tInternational journal of fatigue$$v127$$x0142-1123$$y2019
000864097 8564_ $$uhttps://juser.fz-juelich.de/record/864097/files/New%20insights%20into%20the%20threshold%20behavior%20of%20a%209%20-%2012%20%25%20Cr%20ferritic_martensitic%20steel%20-%20separation%20and%20quantification%20of%20crack%20closure%20mechanisms.pdf$$yPublished on 2019-06-26. Available in OpenAccess from 2021-06-26.
000864097 8564_ $$uhttps://juser.fz-juelich.de/record/864097/files/New%20insights%20into%20the%20threshold%20behavior%20of%20a%209%20-%2012%20%25%20Cr%20ferritic_martensitic%20steel%20-%20separation%20and%20quantification%20of%20crack%20closure%20mechanisms.pdf?subformat=pdfa$$xpdfa$$yPublished on 2019-06-26. Available in OpenAccess from 2021-06-26.
000864097 909CO $$ooai:juser.fz-juelich.de:864097$$pdnbdelivery$$pdriver$$pVDB$$popen_access$$popenaire
000864097 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)161596$$aForschungszentrum Jülich$$b0$$kFZJ
000864097 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129742$$aForschungszentrum Jülich$$b1$$kFZJ
000864097 9131_ $$0G:(DE-HGF)POF3-113$$1G:(DE-HGF)POF3-110$$2G:(DE-HGF)POF3-100$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bEnergie$$lEnergieeffizienz, Materialien und Ressourcen$$vMethods and Concepts for Material Development$$x0
000864097 9141_ $$y2019
000864097 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS
000864097 915__ $$0StatID:(DE-HGF)1160$$2StatID$$aDBCoverage$$bCurrent Contents - Engineering, Computing and Technology
000864097 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search
000864097 915__ $$0StatID:(DE-HGF)0530$$2StatID$$aEmbargoed OpenAccess
000864097 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bINT J FATIGUE : 2017
000864097 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection
000864097 915__ $$0StatID:(DE-HGF)0110$$2StatID$$aWoS$$bScience Citation Index
000864097 915__ $$0StatID:(DE-HGF)0111$$2StatID$$aWoS$$bScience Citation Index Expanded
000864097 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5
000864097 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC
000864097 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline
000864097 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List
000864097 9201_ $$0I:(DE-Juel1)IEK-2-20101013$$kIEK-2$$lWerkstoffstruktur und -eigenschaften$$x0
000864097 9801_ $$aFullTexts
000864097 980__ $$ajournal
000864097 980__ $$aVDB
000864097 980__ $$aUNRESTRICTED
000864097 980__ $$aI:(DE-Juel1)IEK-2-20101013
000864097 981__ $$aI:(DE-Juel1)IMD-1-20101013