| Home > Publications database > Economic and ecologic evaluation of low temperature waste heatintegration into existing district heating > print |
| 001 | 864634 | ||
| 005 | 20240712112903.0 | ||
| 024 | 7 | _ | |a 2128/22852 |2 Handle |
| 037 | _ | _ | |a FZJ-2019-04339 |
| 041 | _ | _ | |a English |
| 100 | 1 | _ | |a Hering, Dominik |0 P:(DE-Juel1)174202 |b 0 |e Corresponding author |u fzj |
| 111 | 2 | _ | |a Building Simulation 2019 |g BS2019 |c Rome |d 2019-09-02 - 2019-09-04 |w Italy |
| 245 | _ | _ | |a Economic and ecologic evaluation of low temperature waste heatintegration into existing district heating |
| 250 | _ | _ | |a 16th |
| 260 | _ | _ | |c 2019 |b International Building Performance Association (IBPSA) |
| 295 | 1 | 0 | |a Proceedings of the International Building Performance Simulation Association |
| 300 | _ | _ | |a 123 |
| 336 | 7 | _ | |a CONFERENCE_PAPER |2 ORCID |
| 336 | 7 | _ | |a Conference Paper |0 33 |2 EndNote |
| 336 | 7 | _ | |a INPROCEEDINGS |2 BibTeX |
| 336 | 7 | _ | |a conferenceObject |2 DRIVER |
| 336 | 7 | _ | |a Output Types/Conference Paper |2 DataCite |
| 336 | 7 | _ | |a Contribution to a conference proceedings |b contrib |m contrib |0 PUB:(DE-HGF)8 |s 1568791009_18935 |2 PUB:(DE-HGF) |
| 336 | 7 | _ | |a Contribution to a book |0 PUB:(DE-HGF)7 |2 PUB:(DE-HGF) |m contb |
| 520 | _ | _ | |a The integration of waste heat into district heating offersthe potential to decrease the environmental impactof the district heating's energy supply. A signi-cant amount of waste heat is available at low temperatures,compared to existing district heating networks.In this paper, we generate a simulation model of a districtheating network from a database and evaluatethe integration of waste heat compared to the originaldesign. Our simulation demonstrates the feasibility ofintegrating low temperature waste heat into an existingnetwork. The waste heat utilization can decreasethe primary energy consumption and CO2 emissionsfor the respective buildings. These results can beimproved further by optimizing the low-temperaturenetwork connection of each building. |
| 536 | _ | _ | |a 153 - Assessment of Energy Systems – Addressing Issues of Energy Efficiency and Energy Security (POF3-153) |0 G:(DE-HGF)POF3-153 |c POF3-153 |f POF III |x 0 |
| 700 | 1 | _ | |a Xhonneux, André |0 P:(DE-Juel1)8457 |b 1 |u fzj |
| 700 | 1 | _ | |a Müller, Dirk |0 P:(DE-Juel1)172026 |b 2 |u fzj |
| 770 | _ | _ | |z 978-1-7750520-1-2 |
| 856 | 4 | _ | |y OpenAccess |u https://juser.fz-juelich.de/record/864634/files/BS2019_final.pdf |
| 856 | 4 | _ | |y OpenAccess |x pdfa |u https://juser.fz-juelich.de/record/864634/files/BS2019_final.pdf?subformat=pdfa |
| 909 | C | O | |o oai:juser.fz-juelich.de:864634 |p openaire |p open_access |p VDB |p driver |p dnbdelivery |
| 910 | 1 | _ | |a Forschungszentrum Jülich |0 I:(DE-588b)5008462-8 |k FZJ |b 0 |6 P:(DE-Juel1)174202 |
| 910 | 1 | _ | |a Forschungszentrum Jülich |0 I:(DE-588b)5008462-8 |k FZJ |b 1 |6 P:(DE-Juel1)8457 |
| 910 | 1 | _ | |a Forschungszentrum Jülich |0 I:(DE-588b)5008462-8 |k FZJ |b 2 |6 P:(DE-Juel1)172026 |
| 913 | 1 | _ | |a DE-HGF |l Technologie, Innovation und Gesellschaft |1 G:(DE-HGF)POF3-150 |0 G:(DE-HGF)POF3-153 |2 G:(DE-HGF)POF3-100 |v Assessment of Energy Systems – Addressing Issues of Energy Efficiency and Energy Security |x 0 |4 G:(DE-HGF)POF |3 G:(DE-HGF)POF3 |b Energie |
| 914 | 1 | _ | |y 2019 |
| 915 | _ | _ | |a OpenAccess |0 StatID:(DE-HGF)0510 |2 StatID |
| 920 | _ | _ | |l yes |
| 920 | 1 | _ | |0 I:(DE-Juel1)IEK-10-20170217 |k IEK-10 |l Modellierung von Energiesystemen |x 0 |
| 980 | 1 | _ | |a FullTexts |
| 980 | _ | _ | |a contrib |
| 980 | _ | _ | |a VDB |
| 980 | _ | _ | |a UNRESTRICTED |
| 980 | _ | _ | |a contb |
| 980 | _ | _ | |a I:(DE-Juel1)IEK-10-20170217 |
| 981 | _ | _ | |a I:(DE-Juel1)ICE-1-20170217 |
| Library | Collection | CLSMajor | CLSMinor | Language | Author |
|---|