000864784 001__ 864784
000864784 005__ 20240709082009.0
000864784 0247_ $$2doi$$a10.1016/j.energy.2019.06.169
000864784 0247_ $$2ISSN$$a0360-5442
000864784 0247_ $$2ISSN$$a1873-6785
000864784 0247_ $$2altmetric$$aaltmetric:63629288
000864784 0247_ $$2WOS$$aWOS:000484869400034
000864784 037__ $$aFZJ-2019-04441
000864784 082__ $$a600
000864784 1001_ $$00000-0001-7570-1344$$aGibelhaus, Andrej$$b0
000864784 245__ $$aIntegrated design and control of full sorption chiller systems
000864784 260__ $$aAmsterdam [u.a.]$$bElsevier Science$$c2019
000864784 3367_ $$2DRIVER$$aarticle
000864784 3367_ $$2DataCite$$aOutput Types/Journal article
000864784 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1568790567_18935
000864784 3367_ $$2BibTeX$$aARTICLE
000864784 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000864784 3367_ $$00$$2EndNote$$aJournal Article
000864784 520__ $$aThermally-driven sorption chillers offer a sustainable alternative to compression chillers. However, the expected benefits of sorption chillers are often not realised in practice due to high electricity consumption of auxiliaries, such as pumps and fans. To obtain an overall optimal full sorption chiller system, we propose a method for integrated optimisation of design and control. The proposed method applies dynamic optimisation to identify optimal control for each investigated system design. Thus, each design is evaluated under optimal control regarding a problem-specific objective, such as electrical efficiency or total costs. We illustrate the method for a case study of a solar-thermally-driven adsorption chiller system. The results are compared to an established design method and nominal control: optimising for electricity demand allows to increase the electrical energy efficiency ratio (EER) by one order of magnitude. When optimising for total costs, optimal control increases the energy efficiency by a factor 4 and decreases the total costs by 28% to 0.13 EUR/kWh. Moving to a cost-optimal design further increases the energy efficiency by 50% to 16.2 and reduces the total costs by another 8%. Thus, the proposed method allows for efficient integrated design and control of full sorption chiller systems.
000864784 536__ $$0G:(DE-HGF)POF3-153$$a153 - Assessment of Energy Systems – Addressing Issues of Energy Efficiency and Energy Security (POF3-153)$$cPOF3-153$$fPOF III$$x0
000864784 588__ $$aDataset connected to CrossRef
000864784 7001_ $$0P:(DE-HGF)0$$aTangkrachang, Thanaphum$$b1
000864784 7001_ $$0P:(DE-Juel1)172630$$aBau, Uwe$$b2
000864784 7001_ $$00000-0002-8461-7993$$aSeiler, Jan$$b3
000864784 7001_ $$0P:(DE-Juel1)172023$$aBardow, André$$b4$$eCorresponding author
000864784 773__ $$0PERI:(DE-600)2019804-8$$a10.1016/j.energy.2019.06.169$$gVol. 185, p. 409 - 422$$p409 - 422$$tEnergy$$v185$$x0360-5442$$y2019
000864784 909CO $$ooai:juser.fz-juelich.de:864784$$pVDB
000864784 9101_ $$0I:(DE-588b)36225-6$$60000-0001-7570-1344$$aRWTH Aachen$$b0$$kRWTH
000864784 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-HGF)0$$aRWTH Aachen$$b1$$kRWTH
000864784 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)172630$$aForschungszentrum Jülich$$b2$$kFZJ
000864784 9101_ $$0I:(DE-588b)36225-6$$60000-0002-8461-7993$$aRWTH Aachen$$b3$$kRWTH
000864784 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)172023$$aForschungszentrum Jülich$$b4$$kFZJ
000864784 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-Juel1)172023$$aRWTH Aachen$$b4$$kRWTH
000864784 9131_ $$0G:(DE-HGF)POF3-153$$1G:(DE-HGF)POF3-150$$2G:(DE-HGF)POF3-100$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bEnergie$$lTechnologie, Innovation und Gesellschaft$$vAssessment of Energy Systems – Addressing Issues of Energy Efficiency and Energy Security$$x0
000864784 9141_ $$y2019
000864784 915__ $$0StatID:(DE-HGF)0420$$2StatID$$aNationallizenz
000864784 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bENERGY : 2017
000864784 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS
000864784 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline
000864784 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search
000864784 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC
000864784 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List
000864784 915__ $$0StatID:(DE-HGF)0110$$2StatID$$aWoS$$bScience Citation Index
000864784 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection
000864784 915__ $$0StatID:(DE-HGF)0111$$2StatID$$aWoS$$bScience Citation Index Expanded
000864784 915__ $$0StatID:(DE-HGF)1160$$2StatID$$aDBCoverage$$bCurrent Contents - Engineering, Computing and Technology
000864784 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5
000864784 920__ $$lyes
000864784 9201_ $$0I:(DE-Juel1)IEK-10-20170217$$kIEK-10$$lModellierung von Energiesystemen$$x0
000864784 980__ $$ajournal
000864784 980__ $$aVDB
000864784 980__ $$aI:(DE-Juel1)IEK-10-20170217
000864784 980__ $$aUNRESTRICTED
000864784 981__ $$aI:(DE-Juel1)ICE-1-20170217