000866894 001__ 866894
000866894 005__ 20240712113055.0
000866894 0247_ $$2doi$$a10.1016/j.est.2018.04.029
000866894 0247_ $$2ISSN$$a2352-152X
000866894 0247_ $$2ISSN$$a2352-1538
000866894 0247_ $$2Handle$$a2128/24275
000866894 0247_ $$2WOS$$aWOS:000439496500014
000866894 037__ $$aFZJ-2019-05954
000866894 082__ $$a333.7
000866894 1001_ $$0P:(DE-HGF)0$$aLewerenz, Meinert$$b0$$eCorresponding author
000866894 245__ $$aIrreversible calendar aging and quantification of the reversible capacity loss caused by anode overhang
000866894 260__ $$aAmsterdam [u.a.]$$bElsevier$$c2018
000866894 3367_ $$2DRIVER$$aarticle
000866894 3367_ $$2DataCite$$aOutput Types/Journal article
000866894 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1581001600_22021
000866894 3367_ $$2BibTeX$$aARTICLE
000866894 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000866894 3367_ $$00$$2EndNote$$aJournal Article
000866894 520__ $$aCalendar aging tests are presented quantifying the reversible capacity loss caused by lithium migration from the active part to the overhang of the anode. Based on these tests, capacity loss at five different SOCs with respect to the anode is evaluated. The remaining capacity shows a non-linear part in the beginning representing the reversible capacity loss caused by the overhang. The subsequent linear part ending after 100–200 days corresponds to the irreversible capacity loss. By extrapolating the linear part to t = 0, the lithium lost to the overhang is measureable for each storage condition. This approach matches well to theoretical values calculated using a simple equation. In later stages of the capacity loss curve, another superposed effect can be observed that decreases capacity fade. The reason is found in an increasing homogeneity of lithium distribution that correlates to the peak height of differential voltage characteristics. In this publication an increasing homogeneity is associated with a higher extractable capacity and vice versa. An especially high increase of homogeneity is observable when a high voltage difference coincides with pressure change due to lithium insertion. Finally, the temperature dependency of the lateral lithium flow is shown for three temperatures at a fixed storage position.
000866894 536__ $$0G:(DE-HGF)POF3-131$$a131 - Electrochemical Storage (POF3-131)$$cPOF3-131$$fPOF III$$x0
000866894 588__ $$aDataset connected to CrossRef
000866894 7001_ $$0P:(DE-HGF)0$$aFuchs, Georg$$b1
000866894 7001_ $$0P:(DE-HGF)0$$aBecker, Lisa$$b2
000866894 7001_ $$0P:(DE-Juel1)172625$$aSauer, Dirk Uwe$$b3
000866894 773__ $$0PERI:(DE-600)2826805-2$$a10.1016/j.est.2018.04.029$$gVol. 18, p. 149 - 159$$p149 - 159$$tJournal of energy storage$$v18$$x2352-152X$$y2018
000866894 8564_ $$uhttps://juser.fz-juelich.de/record/866894/files/2018_quantification_of_overhang.pdf$$yPublished on 2018-05-08. Available in OpenAccess from 2020-05-08.$$zStatID:(DE-HGF)0510
000866894 8564_ $$uhttps://juser.fz-juelich.de/record/866894/files/JournalVersion.pdf$$yRestricted
000866894 8564_ $$uhttps://juser.fz-juelich.de/record/866894/files/2018_quantification_of_overhang.pdf?subformat=pdfa$$xpdfa$$yPublished on 2018-05-08. Available in OpenAccess from 2020-05-08.$$zStatID:(DE-HGF)0510
000866894 8564_ $$uhttps://juser.fz-juelich.de/record/866894/files/JournalVersion.pdf?subformat=pdfa$$xpdfa$$yRestricted
000866894 909CO $$ooai:juser.fz-juelich.de:866894$$pdnbdelivery$$pdriver$$pVDB$$popen_access$$popenaire
000866894 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-HGF)0$$aRWTH Aachen$$b0$$kRWTH
000866894 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-HGF)0$$aRWTH Aachen$$b1$$kRWTH
000866894 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-HGF)0$$aRWTH Aachen$$b2$$kRWTH
000866894 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)172625$$aForschungszentrum Jülich$$b3$$kFZJ
000866894 9131_ $$0G:(DE-HGF)POF3-131$$1G:(DE-HGF)POF3-130$$2G:(DE-HGF)POF3-100$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bEnergie$$lSpeicher und vernetzte Infrastrukturen$$vElectrochemical Storage$$x0
000866894 9141_ $$y2019
000866894 915__ $$0StatID:(DE-HGF)0530$$2StatID$$aEmbargoed OpenAccess
000866894 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS
000866894 915__ $$0StatID:(DE-HGF)0112$$2StatID$$aWoS$$bEmerging Sources Citation Index
000866894 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection
000866894 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List
000866894 920__ $$lyes
000866894 9201_ $$0I:(DE-Juel1)IEK-12-20141217$$kIEK-12$$lHelmholtz-Institut Münster Ionenleiter für Energiespeicher$$x0
000866894 9201_ $$0I:(DE-82)080011_20140620$$kJARA-ENERGY$$lJARA-ENERGY$$x1
000866894 9801_ $$aFullTexts
000866894 980__ $$ajournal
000866894 980__ $$aVDB
000866894 980__ $$aUNRESTRICTED
000866894 980__ $$aI:(DE-Juel1)IEK-12-20141217
000866894 980__ $$aI:(DE-82)080011_20140620
000866894 981__ $$aI:(DE-Juel1)IMD-4-20141217