001     866894
005     20240712113055.0
024 7 _ |a 10.1016/j.est.2018.04.029
|2 doi
024 7 _ |a 2352-152X
|2 ISSN
024 7 _ |a 2352-1538
|2 ISSN
024 7 _ |a 2128/24275
|2 Handle
024 7 _ |a WOS:000439496500014
|2 WOS
037 _ _ |a FZJ-2019-05954
082 _ _ |a 333.7
100 1 _ |a Lewerenz, Meinert
|0 P:(DE-HGF)0
|b 0
|e Corresponding author
245 _ _ |a Irreversible calendar aging and quantification of the reversible capacity loss caused by anode overhang
260 _ _ |a Amsterdam [u.a.]
|c 2018
|b Elsevier
336 7 _ |a article
|2 DRIVER
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1581001600_22021
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
520 _ _ |a Calendar aging tests are presented quantifying the reversible capacity loss caused by lithium migration from the active part to the overhang of the anode. Based on these tests, capacity loss at five different SOCs with respect to the anode is evaluated. The remaining capacity shows a non-linear part in the beginning representing the reversible capacity loss caused by the overhang. The subsequent linear part ending after 100–200 days corresponds to the irreversible capacity loss. By extrapolating the linear part to t = 0, the lithium lost to the overhang is measureable for each storage condition. This approach matches well to theoretical values calculated using a simple equation. In later stages of the capacity loss curve, another superposed effect can be observed that decreases capacity fade. The reason is found in an increasing homogeneity of lithium distribution that correlates to the peak height of differential voltage characteristics. In this publication an increasing homogeneity is associated with a higher extractable capacity and vice versa. An especially high increase of homogeneity is observable when a high voltage difference coincides with pressure change due to lithium insertion. Finally, the temperature dependency of the lateral lithium flow is shown for three temperatures at a fixed storage position.
536 _ _ |a 131 - Electrochemical Storage (POF3-131)
|0 G:(DE-HGF)POF3-131
|c POF3-131
|f POF III
|x 0
588 _ _ |a Dataset connected to CrossRef
700 1 _ |a Fuchs, Georg
|0 P:(DE-HGF)0
|b 1
700 1 _ |a Becker, Lisa
|0 P:(DE-HGF)0
|b 2
700 1 _ |a Sauer, Dirk Uwe
|0 P:(DE-Juel1)172625
|b 3
773 _ _ |a 10.1016/j.est.2018.04.029
|g Vol. 18, p. 149 - 159
|0 PERI:(DE-600)2826805-2
|p 149 - 159
|t Journal of energy storage
|v 18
|y 2018
|x 2352-152X
856 4 _ |y Published on 2018-05-08. Available in OpenAccess from 2020-05-08.
|z StatID:(DE-HGF)0510
|u https://juser.fz-juelich.de/record/866894/files/2018_quantification_of_overhang.pdf
856 4 _ |u https://juser.fz-juelich.de/record/866894/files/JournalVersion.pdf
|y Restricted
856 4 _ |y Published on 2018-05-08. Available in OpenAccess from 2020-05-08.
|x pdfa
|z StatID:(DE-HGF)0510
|u https://juser.fz-juelich.de/record/866894/files/2018_quantification_of_overhang.pdf?subformat=pdfa
856 4 _ |x pdfa
|u https://juser.fz-juelich.de/record/866894/files/JournalVersion.pdf?subformat=pdfa
|y Restricted
909 C O |o oai:juser.fz-juelich.de:866894
|p openaire
|p open_access
|p VDB
|p driver
|p dnbdelivery
910 1 _ |a RWTH Aachen
|0 I:(DE-588b)36225-6
|k RWTH
|b 0
|6 P:(DE-HGF)0
910 1 _ |a RWTH Aachen
|0 I:(DE-588b)36225-6
|k RWTH
|b 1
|6 P:(DE-HGF)0
910 1 _ |a RWTH Aachen
|0 I:(DE-588b)36225-6
|k RWTH
|b 2
|6 P:(DE-HGF)0
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 3
|6 P:(DE-Juel1)172625
913 1 _ |a DE-HGF
|l Speicher und vernetzte Infrastrukturen
|1 G:(DE-HGF)POF3-130
|0 G:(DE-HGF)POF3-131
|2 G:(DE-HGF)POF3-100
|v Electrochemical Storage
|x 0
|4 G:(DE-HGF)POF
|3 G:(DE-HGF)POF3
|b Energie
914 1 _ |y 2019
915 _ _ |a Embargoed OpenAccess
|0 StatID:(DE-HGF)0530
|2 StatID
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
915 _ _ |a WoS
|0 StatID:(DE-HGF)0112
|2 StatID
|b Emerging Sources Citation Index
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0150
|2 StatID
|b Web of Science Core Collection
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0199
|2 StatID
|b Clarivate Analytics Master Journal List
920 _ _ |l yes
920 1 _ |0 I:(DE-Juel1)IEK-12-20141217
|k IEK-12
|l Helmholtz-Institut Münster Ionenleiter für Energiespeicher
|x 0
920 1 _ |0 I:(DE-82)080011_20140620
|k JARA-ENERGY
|l JARA-ENERGY
|x 1
980 1 _ |a FullTexts
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a UNRESTRICTED
980 _ _ |a I:(DE-Juel1)IEK-12-20141217
980 _ _ |a I:(DE-82)080011_20140620
981 _ _ |a I:(DE-Juel1)IMD-4-20141217


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21