000866897 001__ 866897
000866897 005__ 20240712113056.0
000866897 0247_ $$2doi$$a10.3390/app8060873
000866897 0247_ $$2Handle$$a2128/24281
000866897 0247_ $$2altmetric$$aaltmetric:42966116
000866897 0247_ $$2WOS$$aWOS:000436488000032
000866897 037__ $$aFZJ-2019-05957
000866897 082__ $$a600
000866897 1001_ $$0P:(DE-HGF)0$$aKwiecien, Monika$$b0$$eCorresponding author
000866897 245__ $$aDetermination of SoH of Lead-Acid Batteries by Electrochemical Impedance Spectroscopy
000866897 260__ $$aBasel$$bMDPI$$c2018
000866897 3367_ $$2DRIVER$$aarticle
000866897 3367_ $$2DataCite$$aOutput Types/Journal article
000866897 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1581003518_22020
000866897 3367_ $$2BibTeX$$aARTICLE
000866897 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000866897 3367_ $$00$$2EndNote$$aJournal Article
000866897 520__ $$aThe aging mechanisms of lead-acid batteries change the electrochemical characteristics. For example, sulfation influences the active surface area, and corrosion increases the resistance. Therefore, it is expected that the state of health (SoH) can be reflected through differentiable changes in the impedance of a lead-acid battery. However, for lead-acid batteries, no reliable SoH algorithm is available based on single impedance values or the spectrum. Additionally, the characteristic changes of the spectrum during aging are unknown. In this work, lead-acid test cells were aged under specific cycle regimes known as AK3.4, and periodic electrochemical impedance spectroscopy (EIS) measurements and capacity tests were conducted. It was examined that single impedance values increased linearly with capacity decay, but with varying slopes depending on the pre-history of the cell and measurement frequency of impedance. Thereby, possible reasons for ineffective SoH estimation were found. The spectra were fitted to an equivalent electrical circuit containing, besides other elements, an ohmic and a charge-transfer resistance of the negative electrode. The linear increase of the ohmic resistance and the charge-transfer resistance were characterized for the performed cyclic aging test. Results from chemical analysis confirmed the expected aging process and the correlation between capacity decay and impedance change. Furthermore, the positive influence of charging on the SoH could be detected via EIS. The results presented here show that SoH estimation using EIS can be a viable technique for lead-acid batteries
000866897 536__ $$0G:(DE-HGF)POF3-131$$a131 - Electrochemical Storage (POF3-131)$$cPOF3-131$$fPOF III$$x0
000866897 588__ $$aDataset connected to CrossRef
000866897 7001_ $$0P:(DE-HGF)0$$aBadeda, Julia$$b1
000866897 7001_ $$00000-0002-1180-4077$$aHuck, Moritz$$b2
000866897 7001_ $$0P:(DE-HGF)0$$aKomut, Kuebra$$b3
000866897 7001_ $$0P:(DE-HGF)0$$aDuman, Dilek$$b4
000866897 7001_ $$0P:(DE-Juel1)172625$$aSauer, Dirk$$b5$$ufzj
000866897 773__ $$0PERI:(DE-600)2704225-X$$a10.3390/app8060873$$gVol. 8, no. 6, p. 873 -$$n6$$p873 -$$tApplied Sciences$$v8$$x2076-3417$$y2018
000866897 8564_ $$uhttps://juser.fz-juelich.de/record/866897/files/20180607_publishedVersion.pdf$$yOpenAccess
000866897 8564_ $$uhttps://juser.fz-juelich.de/record/866897/files/20180607_publishedVersion.pdf?subformat=pdfa$$xpdfa$$yOpenAccess
000866897 909CO $$ooai:juser.fz-juelich.de:866897$$pdnbdelivery$$pdriver$$pVDB$$popen_access$$popenaire
000866897 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-HGF)0$$aRWTH Aachen$$b0$$kRWTH
000866897 9101_ $$0I:(DE-588b)36225-6$$60000-0002-1180-4077$$aRWTH Aachen$$b2$$kRWTH
000866897 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-HGF)0$$aRWTH Aachen$$b3$$kRWTH
000866897 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-HGF)0$$aRWTH Aachen$$b4$$kRWTH
000866897 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)172625$$aForschungszentrum Jülich$$b5$$kFZJ
000866897 9131_ $$0G:(DE-HGF)POF3-131$$1G:(DE-HGF)POF3-130$$2G:(DE-HGF)POF3-100$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bEnergie$$lSpeicher und vernetzte Infrastrukturen$$vElectrochemical Storage$$x0
000866897 9141_ $$y2019
000866897 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS
000866897 915__ $$0StatID:(DE-HGF)1160$$2StatID$$aDBCoverage$$bCurrent Contents - Engineering, Computing and Technology
000866897 915__ $$0LIC:(DE-HGF)CCBY4$$2HGFVOC$$aCreative Commons Attribution CC BY 4.0
000866897 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bAPPL SCI-BASEL : 2017
000866897 915__ $$0StatID:(DE-HGF)0501$$2StatID$$aDBCoverage$$bDOAJ Seal
000866897 915__ $$0StatID:(DE-HGF)0500$$2StatID$$aDBCoverage$$bDOAJ
000866897 915__ $$0StatID:(DE-HGF)0111$$2StatID$$aWoS$$bScience Citation Index Expanded
000866897 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection
000866897 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5
000866897 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000866897 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bDOAJ : Blind peer review
000866897 915__ $$0StatID:(DE-HGF)1150$$2StatID$$aDBCoverage$$bCurrent Contents - Physical, Chemical and Earth Sciences
000866897 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline
000866897 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List
000866897 920__ $$lyes
000866897 9201_ $$0I:(DE-Juel1)IEK-12-20141217$$kIEK-12$$lHelmholtz-Institut Münster Ionenleiter für Energiespeicher$$x0
000866897 9201_ $$0I:(DE-82)080011_20140620$$kJARA-ENERGY$$lJARA-ENERGY$$x1
000866897 9801_ $$aFullTexts
000866897 980__ $$ajournal
000866897 980__ $$aVDB
000866897 980__ $$aUNRESTRICTED
000866897 980__ $$aI:(DE-Juel1)IEK-12-20141217
000866897 980__ $$aI:(DE-82)080011_20140620
000866897 981__ $$aI:(DE-Juel1)IMD-4-20141217