000867592 001__ 867592
000867592 005__ 20240711114105.0
000867592 0247_ $$2doi$$a10.1088/1741-4326/aa4f83
000867592 0247_ $$2ISSN$$a0029-5515
000867592 0247_ $$2ISSN$$a1741-4326
000867592 0247_ $$2WOS$$aWOS:000394509200001
000867592 0247_ $$2Handle$$a2128/24784
000867592 037__ $$aFZJ-2019-06213
000867592 082__ $$a620
000867592 1001_ $$0P:(DE-Juel1)137057$$aEffenberg, F.$$b0$$eCorresponding author
000867592 245__ $$aNumerical investigation of plasma edge transport and limiter heat fluxes in Wendelstein 7-X startup plasmas with EMC3-EIRENE
000867592 260__ $$aVienna$$bIAEA$$c2017
000867592 3367_ $$2DRIVER$$aarticle
000867592 3367_ $$2DataCite$$aOutput Types/Journal article
000867592 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1575537588_2091
000867592 3367_ $$2BibTeX$$aARTICLE
000867592 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000867592 3367_ $$00$$2EndNote$$aJournal Article
000867592 520__ $$aThe results of a first systematic assessment of plasma edge transport processes for the limiter startup configuration at Wendelstein 7-X are presented. This includes an investigation of transport from intrinsic and externally injected impurities and their impact on the power balance and limiter heat fluxes. The fully 3D coupled plasma fluid and kinetic neutral transport Monte Carlo code EMC3-EIRENE is used.The analysis of the magnetic topology shows that the poloidally and toroidally localized limiters cause a 3D helical scrape-off layer (SOL) consisting of magnetic flux tubes of three different connection lengths L C. The transport in the helical SOL is governed by L C as topological scale length for the parallel plasma loss channel to the limiters. A clear modulation of the plasma pressure with L C is seen. The helical flux tube topology results in counter streaming sonic plasma flows.The heterogeneous SOL plasma structure yields an uneven limiter heat load distribution with localized peaking. Assuming spatially constant anomalous transport coefficients, increasing plasma density yields a reduction of the maximum peak heat loads from 12 MWm−2 to 7.5 MWm−2 and a broadening of the deposited heat fluxes. ...
000867592 536__ $$0G:(DE-HGF)POF3-174$$a174 - Plasma-Wall-Interaction (POF3-174)$$cPOF3-174$$fPOF III$$x0
000867592 588__ $$aDataset connected to CrossRef
000867592 7001_ $$0P:(DE-Juel1)6982$$aFeng, Y.$$b1
000867592 7001_ $$0P:(DE-Juel1)6790$$aSchmitz, O.$$b2
000867592 7001_ $$0P:(DE-Juel1)6766$$aFrerichs, H.$$b3
000867592 7001_ $$0P:(DE-HGF)0$$aBozhenkov, S. A.$$b4
000867592 7001_ $$0P:(DE-HGF)0$$aHölbe, H.$$b5
000867592 7001_ $$0P:(DE-Juel1)159297$$aKönig, R.$$b6
000867592 7001_ $$0P:(DE-HGF)0$$aKrychowiak, M.$$b7
000867592 7001_ $$0P:(DE-HGF)0$$aPedersen, T. Sunn$$b8
000867592 7001_ $$0P:(DE-Juel1)5006$$aReiter, D.$$b9
000867592 7001_ $$0P:(DE-HGF)0$$aStephey, L.$$b10
000867592 773__ $$0PERI:(DE-600)2037980-8$$a10.1088/1741-4326/aa4f83$$gVol. 57, no. 3, p. 036021 -$$n3$$p036021 -$$tNuclear fusion$$v57$$x1741-4326$$y2017
000867592 8564_ $$uhttps://juser.fz-juelich.de/record/867592/files/Effenberg_2017_Nucl._Fusion_57_036021.pdf$$yRestricted
000867592 8564_ $$uhttps://juser.fz-juelich.de/record/867592/files/Effenberg_2017_Nucl._Fusion_57_036021.pdf?subformat=pdfa$$xpdfa$$yRestricted
000867592 8564_ $$uhttps://juser.fz-juelich.de/record/867592/files/WPS1PR16_15966_submitted.pdf$$yOpenAccess
000867592 8564_ $$uhttps://juser.fz-juelich.de/record/867592/files/WPS1PR16_15966_submitted.pdf?subformat=pdfa$$xpdfa$$yOpenAccess
000867592 909CO $$ooai:juser.fz-juelich.de:867592$$pdnbdelivery$$pdriver$$pVDB$$popen_access$$popenaire
000867592 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)6790$$aForschungszentrum Jülich$$b2$$kFZJ
000867592 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)159297$$aForschungszentrum Jülich$$b6$$kFZJ
000867592 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)5006$$aForschungszentrum Jülich$$b9$$kFZJ
000867592 9131_ $$0G:(DE-HGF)POF3-174$$1G:(DE-HGF)POF3-170$$2G:(DE-HGF)POF3-100$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bEnergie$$lKernfusion$$vPlasma-Wall-Interaction$$x0
000867592 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS
000867592 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search
000867592 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bNUCL FUSION : 2017
000867592 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection
000867592 915__ $$0StatID:(DE-HGF)0110$$2StatID$$aWoS$$bScience Citation Index
000867592 915__ $$0StatID:(DE-HGF)0111$$2StatID$$aWoS$$bScience Citation Index Expanded
000867592 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5
000867592 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000867592 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC
000867592 915__ $$0StatID:(DE-HGF)1150$$2StatID$$aDBCoverage$$bCurrent Contents - Physical, Chemical and Earth Sciences
000867592 915__ $$0StatID:(DE-HGF)0430$$2StatID$$aNational-Konsortium
000867592 915__ $$0StatID:(DE-HGF)0420$$2StatID$$aNationallizenz
000867592 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List
000867592 920__ $$lyes
000867592 9201_ $$0I:(DE-Juel1)IEK-4-20101013$$kIEK-4$$lPlasmaphysik$$x0
000867592 9801_ $$aFullTexts
000867592 980__ $$ajournal
000867592 980__ $$aVDB
000867592 980__ $$aUNRESTRICTED
000867592 980__ $$aI:(DE-Juel1)IEK-4-20101013
000867592 981__ $$aI:(DE-Juel1)IFN-1-20101013