@INPROCEEDINGS{Kumar:868003,
      author       = {Kumar, Shashank and Herzkamp, Matthias and van Waasen,
                      Stefan},
      title        = {{N}on-linearity {A}nalysis of digital {S}i{PM} arrays
                      response in a {P}osition {S}ensitive {N}eutron {D}etector
                      {P}rototype},
      reportid     = {FZJ-2019-06596},
      year         = {2018},
      abstract     = {Silicon photomultipliers (SiPM) are solid-state
                      photodetectors based on Geiger mode avalanche diode
                      technology. The features of SiPMs such as low operating
                      voltages, insusceptibility to magnetic field and low
                      production costs make it a very appealing candidate for
                      single photon detection applications. In the recent past its
                      applicability in neutron detection had been assessed and
                      proved feasible. Motivated by this investigation, a new kind
                      of scintillation neutron detector based on digital SiPMs is
                      under development. This detector prototype with an active
                      area of 13 cm × 13 cm, is assembled with SiPM modules from
                      Philips Digital Photon Counting and a 6Li glass
                      scintillator. It is aimed to be used in the future for
                      neutron reflectometry (NR) at the Heinz Maier-Leibnitz
                      Zentrum (MLZ) in Garching, Germany for the TREFF instrument.
                      In order to achieve the goal of two dimensional spatial
                      resolution of 1 mm × 1 mm, and a neutron counting rate of
                      20 Mcps/m², non-linearity characterization of the SiPM has
                      been performed. This work presents the simulation results
                      performed using Geant4 tool-kit for the SiPM proportionality
                      response at the pixel and cell levels under the design
                      considerations of this detector prototype.},
      month         = {Nov},
      date          = {2018-11-10},
      organization  = {IEEE Nuclear Science Symposium and
                       Medical Imaging Conference, Sydney
                       (Australia), 10 Nov 2018 - 18 Nov 2018},
      subtyp        = {After Call},
      cin          = {ZEA-2},
      cid          = {I:(DE-Juel1)ZEA-2-20090406},
      pnm          = {632 - Detector technology and systems (POF3-632)},
      pid          = {G:(DE-HGF)POF3-632},
      experiment   = {EXP:(DE-MLZ)TREFF-20140101},
      typ          = {PUB:(DE-HGF)24},
      url          = {https://juser.fz-juelich.de/record/868003},
}