Conference Presentation (After Call) FZJ-2019-06601

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Timing Resolution of SiPM technologies before and after neutron irradiation

 ;  ;  ;  ;

2019

International Workshop on Radiation Imaging Detectors, IWORID, CRETECRETE, Greece, 7 Jul 2019 - 12 Jul 20192019-07-072019-07-12

Abstract: In recent years, silicon photomultiplier (SiPM) technology is getting attention from various applications due to its low cost, immunity to magnetic field, compactness and ruggedness. However, its applicability in experiments with harsh radiation environments is still limited due to lack of corresponding radiation damage studies. A typical 10-year lifetime operation in a typical Small Angle Neutron Scattering experiment [1] with an acceptable PDE degradation [2] has already been reported, and in this study, the timing resolutions of SiPMs before and after exposure with cold neutrons (5 Å) were compared. For this purpose, two analog SiPMs, developed by SensL and Hamamatsu, and a digital SiPM manufactured by Philips Digital Photon Counting were irradiated up to a dose of 6∙1012n/cm2 at the KWS-1 instrument of the Heinz Maier-Leibnitz Zentrum (MLZ) in Garching.The used measurement system consists of a 403 nm Laser with a pulse width of 45 ps FWHM, and an oscilloscope (40 GS/s, 14 GHz) for data acquisition. During the characterization campaign, a time resolutions has been measured using ~500 photon pulses impinging on the SiPMs, which were kept under constant temperature of 21 °C. The first result of SensL SiPM show no significant difference in jitter values before and after irradiation up to a dose of 1.9E12 n/cm2. The performed tests provide an insight into feasibility of implementing SiPM based fast and efficient scintillation light detectors for applications such as neutron time-of-flight scattering experiments.

Keyword(s): Engineering, Industrial Materials and Processing (1st) ; Instrument and Method Development (2nd)


Contributing Institute(s):
  1. Zentralinstitut für Elektronik (ZEA-2)
Research Program(s):
  1. 632 - Detector technology and systems (POF3-632) (POF3-632)
Experiment(s):
  1. TREFF: Neutronenreflektometer (NL5S)

Appears in the scientific report 2019
Click to display QR Code for this record

The record appears in these collections:
Document types > Presentations > Conference Presentations
Institute Collections > ZEA > ZEA-2
Institute Collections > PGI > PGI-4
Workflow collections > Public records
Publications database

 Record created 2019-12-16, last modified 2025-01-29


External link:
Download fulltext
Fulltext
Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)