| Home > Publications database > Amperometric Aptasensor for Amyloid-β Oligomer Detection by Optimized Stem-Loop Structures with an Adjustable Detection Range > print |
| 001 | 872749 | ||
| 005 | 20210130004300.0 | ||
| 024 | 7 | _ | |a 10.1021/acssensors.9b01630 |2 doi |
| 024 | 7 | _ | |a altmetric:70020793 |2 altmetric |
| 024 | 7 | _ | |a pmid:31674772 |2 pmid |
| 024 | 7 | _ | |a WOS:000499737100028 |2 WOS |
| 024 | 7 | _ | |a 2128/24362 |2 Handle |
| 037 | _ | _ | |a FZJ-2020-00227 |
| 082 | _ | _ | |a 570 |
| 100 | 1 | _ | |a Zhang, Yuting |0 P:(DE-Juel1)168161 |b 0 |u fzj |
| 245 | _ | _ | |a Amperometric Aptasensor for Amyloid-β Oligomer Detection by Optimized Stem-Loop Structures with an Adjustable Detection Range |
| 260 | _ | _ | |a Washington, DC |c 2019 |b ACS Publications |
| 336 | 7 | _ | |a article |2 DRIVER |
| 336 | 7 | _ | |a Output Types/Journal article |2 DataCite |
| 336 | 7 | _ | |a Journal Article |b journal |m journal |0 PUB:(DE-HGF)16 |s 1581424596_17628 |2 PUB:(DE-HGF) |
| 336 | 7 | _ | |a ARTICLE |2 BibTeX |
| 336 | 7 | _ | |a JOURNAL_ARTICLE |2 ORCID |
| 336 | 7 | _ | |a Journal Article |0 0 |2 EndNote |
| 520 | _ | _ | |a Amyloid-β oligomers (AβO) have become representative biomarkers for early diagnosis of Alzheimer's disease. Here, we report on an aptasensor based on stem-loop probes for sensitive and specific detection of AβO by an amperometric transducer principle using alternating current voltammetry (ACV). Stem-loop probes with redox-active moieties are immobilized on a gold substrate as a receptor element. The signal transduction mechanism relies on redox ferrocene (Fc) reporting via charge transfer on a molecular recognition event involving a conformational change of the molecular beacon. The stem-loop structures were optimized by considering the aptamers' stem length, spacer, and different ferrocene terminals. In addition, the sensor assembly and signal recording including aptamer concentration and ACV frequency dependence are discussed. Using the optimized stem-loop probe (B-3' Fc), the aptasensor showed a decrease of the Fc peak current induced by AβO binding within the broad concentration range spanning 6 orders of magnitude. Furthermore, the detection limit of the sensor can be further decreased by optimizing the ACV frequency, however at the cost of a narrowed detection range. In this work, a label-free electrochemical aptasensor is demonstrated, which facilitates the quantification of the concentration of AβO with high selectivity and subpicomolar sensitivity, which may be conducive to improving the diagnosis and pharmacology studies of Alzheimer's disease. |
| 536 | _ | _ | |a 553 - Physical Basis of Diseases (POF3-553) |0 G:(DE-HGF)POF3-553 |c POF3-553 |f POF III |x 0 |
| 588 | _ | _ | |a Dataset connected to CrossRef |
| 700 | 1 | _ | |a Figueroa-Miranda, Gabriela |0 P:(DE-HGF)0 |b 1 |
| 700 | 1 | _ | |a Zafiu, Christian |0 P:(DE-Juel1)162137 |b 2 |u fzj |
| 700 | 1 | _ | |a Willbold, Dieter |0 P:(DE-Juel1)132029 |b 3 |
| 700 | 1 | _ | |a Offenhäusser, Andreas |0 P:(DE-Juel1)128713 |b 4 |
| 700 | 1 | _ | |a Mayer, Dirk |0 P:(DE-Juel1)128707 |b 5 |e Corresponding author |
| 773 | _ | _ | |a 10.1021/acssensors.9b01630 |g Vol. 4, no. 11, p. 3042 - 3050 |0 PERI:(DE-600)2843497-3 |n 11 |p 3042 - 3050 |t ACS sensors |v 4 |y 2019 |x 2379-3694 |
| 856 | 4 | _ | |u https://juser.fz-juelich.de/record/872749/files/acssensors.9b01630.pdf |y Restricted |
| 856 | 4 | _ | |x pdfa |u https://juser.fz-juelich.de/record/872749/files/acssensors.9b01630.pdf?subformat=pdfa |y Restricted |
| 856 | 4 | _ | |y Published on 2019-11-01. Available in OpenAccess from 2020-11-01. |u https://juser.fz-juelich.de/record/872749/files/Autorenmanuskript.pdf |
| 856 | 4 | _ | |y Published on 2019-11-01. Available in OpenAccess from 2020-11-01. |x pdfa |u https://juser.fz-juelich.de/record/872749/files/Autorenmanuskript.pdf?subformat=pdfa |
| 909 | C | O | |o oai:juser.fz-juelich.de:872749 |p openaire |p open_access |p VDB |p driver |p dnbdelivery |
| 910 | 1 | _ | |a Forschungszentrum Jülich |0 I:(DE-588b)5008462-8 |k FZJ |b 0 |6 P:(DE-Juel1)168161 |
| 910 | 1 | _ | |a Forschungszentrum Jülich |0 I:(DE-588b)5008462-8 |k FZJ |b 2 |6 P:(DE-Juel1)162137 |
| 910 | 1 | _ | |a Forschungszentrum Jülich |0 I:(DE-588b)5008462-8 |k FZJ |b 3 |6 P:(DE-Juel1)132029 |
| 910 | 1 | _ | |a Forschungszentrum Jülich |0 I:(DE-588b)5008462-8 |k FZJ |b 4 |6 P:(DE-Juel1)128713 |
| 910 | 1 | _ | |a Forschungszentrum Jülich |0 I:(DE-588b)5008462-8 |k FZJ |b 5 |6 P:(DE-Juel1)128707 |
| 913 | 1 | _ | |a DE-HGF |b Key Technologies |l BioSoft – Fundamentals for future Technologies in the fields of Soft Matter and Life Sciences |1 G:(DE-HGF)POF3-550 |0 G:(DE-HGF)POF3-553 |2 G:(DE-HGF)POF3-500 |v Physical Basis of Diseases |x 0 |4 G:(DE-HGF)POF |3 G:(DE-HGF)POF3 |
| 914 | 1 | _ | |y 2019 |
| 915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0200 |2 StatID |b SCOPUS |
| 915 | _ | _ | |a Embargoed OpenAccess |0 StatID:(DE-HGF)0530 |2 StatID |
| 915 | _ | _ | |a JCR |0 StatID:(DE-HGF)0100 |2 StatID |b ACS SENSORS : 2017 |
| 915 | _ | _ | |a IF >= 5 |0 StatID:(DE-HGF)9905 |2 StatID |b ACS SENSORS : 2017 |
| 915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0150 |2 StatID |b Web of Science Core Collection |
| 915 | _ | _ | |a WoS |0 StatID:(DE-HGF)0111 |2 StatID |b Science Citation Index Expanded |
| 915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)1150 |2 StatID |b Current Contents - Physical, Chemical and Earth Sciences |
| 915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0300 |2 StatID |b Medline |
| 915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0199 |2 StatID |b Clarivate Analytics Master Journal List |
| 920 | _ | _ | |l yes |
| 920 | 1 | _ | |0 I:(DE-Juel1)ICS-6-20110106 |k ICS-6 |l Strukturbiochemie |x 0 |
| 980 | 1 | _ | |a FullTexts |
| 980 | _ | _ | |a journal |
| 980 | _ | _ | |a VDB |
| 980 | _ | _ | |a UNRESTRICTED |
| 980 | _ | _ | |a I:(DE-Juel1)ICS-6-20110106 |
| 981 | _ | _ | |a I:(DE-Juel1)IBI-7-20200312 |
| Library | Collection | CLSMajor | CLSMinor | Language | Author |
|---|