245 _ _ |a Application of compressed sensing using chirp encoded 3D GRE and MPRAGE sequences
260 _ _ |a New York, NY [u.a.]
|c 2020
|b Wiley
336 7 _ |a article
|2 DRIVER
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1599570306_3001
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
520 _ _ |a An implementation of Non‐Fourier chirp‐encoding in 3D Gradient Recalled Echo (GRE), susceptibility‐weighted imaging (SWI) and Magnetization Prepared Rapid Gradient Echo (MPRAGE) sequences is presented with compressive sensing reconstruction. 3D GRE and MPRAGE sequences were designed, in which the phase encoding (PE) direction was encoded with spatially selective chirp encoding Radio Frequency (RF) pulses, while the slice and the readout directions were Fourier encoded using gradients. During each excitation along the PE direction, a different spatially‐selective RF excitation pulse was used to encode the PE direction with a complete set of unitary chirp encoding basis. Multichannel compressive sensing reconstruction on the undersampled in vivo data demonstrated that images reconstructed from chirp encoded data were able to preserve the spatial resolution better than the Fourier encoding. The mean Structural Similarity (SSIM) across five subjects at the acceleration factor of 6, for chirp encoded MPRAGE was 0.934 compared to 0.912 for Fourier encoded MPRAGE. The implementation of prospective undersampling demonstrated the feasibility of using chirp encoding in clinical practice for accelerated imaging. The minimum intensity projection of the compressive sensing (CS) reconstructed susceptibility weighted images revealed that chirp encoding is able to delineate small vessels better than the Fourier encoding with the SSIM of 0.960 for chirp encoding compared to the SSIM of 0.949 for the Fourier encoding. Improved performance of chirp encoding for CS reconstruction and SWI, along with the feasibility of implementation makes them a practical candidate for clinical MRI scans.
536 _ _ |a 573 - Neuroimaging (POF3-573)
|0 G:(DE-HGF)POF3-573
|c POF3-573
|f POF III
|x 0
588 _ _ |a Dataset connected to CrossRef
700 1 _ |a Chen, Zhaolin
|0 P:(DE-HGF)0
|b 1
700 1 _ |a Zhang, Jingxin
|0 P:(DE-HGF)0
|b 2
700 1 _ |a Shah, N. Jon
|0 P:(DE-Juel1)131794
|b 3
700 1 _ |a Egan, Gary F.
|0 P:(DE-HGF)0
|b 4
773 _ _ |a 10.1002/ima.22401
|g p. ima.22401
|0 PERI:(DE-600)2009087-0
|n 3
|p 592-604
|t International journal of imaging systems and technology
|v 30
|y 2020
|x 1098-1098
856 4 _ |y Published on 2020-02-03. Available in OpenAccess from 2021-02-03.
|u https://juser.fz-juelich.de/record/873941/files/Postprint_2020_Pawar_Imaging_Systems_Tech.pdf
856 4 _ |y Published on 2020-02-03. Available in OpenAccess from 2021-02-03.
|x pdfa
|u https://juser.fz-juelich.de/record/873941/files/Postprint_2020_Pawar_Imaging_Systems_Tech.pdf?subformat=pdfa
909 C O |o oai:juser.fz-juelich.de:873941
|p openaire
|p open_access
|p VDB
|p driver
|p dnbdelivery
910 1 _ |a External Institute
|0 I:(DE-HGF)0
|k Extern
|b 0
|6 0000-0001-6199-2312
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 3
|6 P:(DE-Juel1)131794
913 1 _ |a DE-HGF
|b Key Technologies
|l Decoding the Human Brain
|1 G:(DE-HGF)POF3-570
|0 G:(DE-HGF)POF3-573
|2 G:(DE-HGF)POF3-500
|v Neuroimaging
|x 0
|4 G:(DE-HGF)POF
|3 G:(DE-HGF)POF3
914 1 _ |y 2020
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1160
|2 StatID
|b Current Contents - Engineering, Computing and Technology
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0600
|2 StatID
|b Ebsco Academic Search
915 _ _ |a Embargoed OpenAccess
|0 StatID:(DE-HGF)0530
|2 StatID
915 _ _ |a JCR
|0 StatID:(DE-HGF)0100
|2 StatID
|b INT J IMAG SYST TECH : 2017
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0150
|2 StatID
|b Web of Science Core Collection
915 _ _ |a WoS
|0 StatID:(DE-HGF)0111
|2 StatID
|b Science Citation Index Expanded
915 _ _ |a IF < 5
|0 StatID:(DE-HGF)9900
|2 StatID
915 _ _ |a Peer Review
|0 StatID:(DE-HGF)0030
|2 StatID
|b ASC
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0300
|2 StatID
|b Medline
915 _ _ |a Nationallizenz
|0 StatID:(DE-HGF)0420
|2 StatID
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0199
|2 StatID
|b Clarivate Analytics Master Journal List
920 1 _ |0 I:(DE-Juel1)INM-4-20090406
|k INM-4
|l Physik der Medizinischen Bildgebung
|x 0
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a UNRESTRICTED
980 _ _ |a I:(DE-Juel1)INM-4-20090406
980 1 _ |a FullTexts


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21