% IMPORTANT: The following is UTF-8 encoded. This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.
@ARTICLE{Cecconello:874308,
author = {Cecconello, M. and Conroy, S. and Ericsson, G. and
Hjalmarsson, H. and Franke, T. and Biel, W.},
title = {{P}re-conceptual study of the {E}uropean {DEMO} neutron
diagnostics},
journal = {Journal of Instrumentation},
volume = {14},
number = {09},
issn = {1748-0221},
address = {London},
publisher = {Inst. of Physics},
reportid = {FZJ-2020-01356},
pages = {C09001 - C09001},
year = {2019},
abstract = {This paper discusses the pre-conceptual design of the
European DEMO neutron diagnostics aimed at the measurement
of the fusion power, the plasma displacement and the fuel
ion ratio for plasma burn control. The design has been based
on the European DEMO design concept with a single divertor
and on the so-called DEMO1 plasma scenario but limited only
to the steady phased of the discharge. The suggested neutron
diagnostics consist of neutron activation systems, fission
chambers and vertical and horizontal collimated neutron flux
monitors with spectroscopy capabilities. The fusion power
can be measured with an accuracy of $1\%$ with a time
resolution of one tenth of the energy confinement time and
the plasma displacement with a time resolution of 1 ms.
Central ion temperature and fuel ion ratio instead can be
measured with a time resolution of about 1 s. Calibration
and interfacing issues are discussed.},
cin = {IEK-4},
ddc = {610},
cid = {I:(DE-Juel1)IEK-4-20101013},
pnm = {174 - Plasma-Wall-Interaction (POF3-174)},
pid = {G:(DE-HGF)POF3-174},
typ = {PUB:(DE-HGF)16},
UT = {WOS:000486989800001},
doi = {10.1088/1748-0221/14/09/C09001},
url = {https://juser.fz-juelich.de/record/874308},
}