% IMPORTANT: The following is UTF-8 encoded.  This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.

@ARTICLE{Zhukeshov:874864,
      author       = {Zhukeshov, A. M. and Moldabekov, Zh. M. and Ioffe,
                      Alexander},
      title        = {{T}he plasma parameters and neutron yield at device of
                      "{P}lasma focus"},
      journal      = {Physical Sciences and Technology},
      volume       = {6},
      number       = {1},
      issn         = {2409-6121},
      address      = {Almaty},
      publisher    = {Al-Farabi Kazakh National University},
      reportid     = {FZJ-2020-01669},
      pages        = {68-74},
      year         = {2019},
      abstract     = {Present work presents calculations and experimental studies
                      on the formation and dynamics of plasma onthe “plasma
                      focus” set up. Physical conditions were determined and
                      critical parameters were calculatedfor estimating the
                      neutron yield for kilojoule and megajoule set ups. The
                      results of plasma diagnostics andflow formation in the
                      CPA-30 and PF-4 set ups are also shown. A comparison of
                      calculated data andexperimental values is performed. The
                      value of the neutron yield parameter is justified and the
                      possiblecause of the appearance of saturation is indicated.
                      The rationale for the development of further research inthe
                      direction of creating conditions for thermonuclear fusion in
                      installations of the plasma focus type isgiven. The neutron
                      flux was observed on high-voltage gas discharges with a
                      specific geometry of theelectrodes. The result of measuring
                      the anisotropy of the neutron yield along the axial z and
                      radial φdirections was equal to Yn(z)/Yn(φ)~ 2 ÷ 3, which
                      contradicts the thermonuclear mechanism.},
      cin          = {JCNS-FRM-II / JCNS-2 / MLZ},
      ddc          = {530},
      cid          = {I:(DE-Juel1)JCNS-FRM-II-20110218 /
                      I:(DE-Juel1)JCNS-2-20110106 / I:(DE-588b)4597118-3},
      pnm          = {6G4 - Jülich Centre for Neutron Research (JCNS) (POF3-623)
                      / 6G15 - FRM II / MLZ (POF3-6G15)},
      pid          = {G:(DE-HGF)POF3-6G4 / G:(DE-HGF)POF3-6G15},
      experiment   = {EXP:(DE-MLZ)NOSPEC-20140101},
      typ          = {PUB:(DE-HGF)16},
      doi          = {10.26577/phst-2019-1-p2},
      url          = {https://juser.fz-juelich.de/record/874864},
}