000877618 001__ 877618
000877618 005__ 20240709081915.0
000877618 0247_ $$2doi$$a10.1016/j.energy.2019.03.132
000877618 0247_ $$2ISSN$$a0360-5442
000877618 0247_ $$2ISSN$$a1873-6785
000877618 0247_ $$2altmetric$$aaltmetric:58855632
000877618 0247_ $$2WOS$$aWOS:000466999400104
000877618 037__ $$aFZJ-2020-02333
000877618 082__ $$a600
000877618 1001_ $$0P:(DE-HGF)0$$aLeenders, Ludger$$b0
000877618 245__ $$aCoordinating scheduling of production and utility system using a Stackelberg game
000877618 260__ $$aAmsterdam [u.a.]$$bElsevier Science$$c2019
000877618 3367_ $$2DRIVER$$aarticle
000877618 3367_ $$2DataCite$$aOutput Types/Journal article
000877618 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1592912335_7977
000877618 3367_ $$2BibTeX$$aARTICLE
000877618 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000877618 3367_ $$00$$2EndNote$$aJournal Article
000877618 520__ $$aOperation of the production system and of the utility system is commonly optimized separately without feedback between them. This separated planning in general increases total costs. Conceptually, a joint optimization of production and utility system is desirable, but often not possible in practice. We overcome such practical limitations by proposing a repeated Stackelberg game. In the proposed method, the production schedule is determined such that costs for both production and utility system are reduced. For this purpose, price information are passed from the utility system to the production system leading to fast convergence of the repeated Stackelberg game. The proposed repeated Stackelberg game is applied to two literature-based case studies. The proposed method reduces the total costs in one repetition by 9% and 5%. The suggested method provides an effective and practical approach to operate systems with reduced minimal total costs in practice.
000877618 536__ $$0G:(DE-HGF)POF3-899$$a899 - ohne Topic (POF3-899)$$cPOF3-899$$fPOF III$$x0
000877618 588__ $$aDataset connected to CrossRef
000877618 7001_ $$0P:(DE-HGF)0$$aBahl, Björn$$b1
000877618 7001_ $$0P:(DE-HGF)0$$aHennen, Maike$$b2
000877618 7001_ $$0P:(DE-Juel1)172023$$aBardow, André$$b3$$eCorresponding author$$ufzj
000877618 773__ $$0PERI:(DE-600)2019804-8$$a10.1016/j.energy.2019.03.132$$gVol. 175, p. 1283 - 1295$$p1283 - 1295$$tEnergy$$v175$$x0360-5442$$y2019
000877618 909CO $$ooai:juser.fz-juelich.de:877618$$pVDB
000877618 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-HGF)0$$aRWTH Aachen$$b0$$kRWTH
000877618 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-HGF)0$$aRWTH Aachen$$b1$$kRWTH
000877618 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-HGF)0$$aRWTH Aachen$$b2$$kRWTH
000877618 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)172023$$aForschungszentrum Jülich$$b3$$kFZJ
000877618 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-Juel1)172023$$aRWTH Aachen$$b3$$kRWTH
000877618 9131_ $$0G:(DE-HGF)POF3-899$$1G:(DE-HGF)POF3-890$$2G:(DE-HGF)POF3-800$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bProgrammungebundene Forschung$$lohne Programm$$vohne Topic$$x0
000877618 9141_ $$y2020
000877618 915__ $$0StatID:(DE-HGF)0420$$2StatID$$aNationallizenz$$d2020-01-10$$wger
000877618 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline$$d2020-01-10
000877618 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2020-01-10
000877618 915__ $$0StatID:(DE-HGF)0110$$2StatID$$aWoS$$bScience Citation Index$$d2020-01-10
000877618 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2020-01-10
000877618 915__ $$0StatID:(DE-HGF)0111$$2StatID$$aWoS$$bScience Citation Index Expanded$$d2020-01-10
000877618 915__ $$0StatID:(DE-HGF)0160$$2StatID$$aDBCoverage$$bEssential Science Indicators$$d2020-01-10
000877618 915__ $$0StatID:(DE-HGF)1160$$2StatID$$aDBCoverage$$bCurrent Contents - Engineering, Computing and Technology$$d2020-01-10
000877618 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bENERGY : 2018$$d2020-01-10
000877618 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2020-01-10
000877618 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search$$d2020-01-10
000877618 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC$$d2020-01-10
000877618 915__ $$0StatID:(DE-HGF)9905$$2StatID$$aIF >= 5$$bENERGY : 2018$$d2020-01-10
000877618 920__ $$lyes
000877618 9201_ $$0I:(DE-Juel1)IEK-10-20170217$$kIEK-10$$lModellierung von Energiesystemen$$x0
000877618 980__ $$ajournal
000877618 980__ $$aVDB
000877618 980__ $$aI:(DE-Juel1)IEK-10-20170217
000877618 980__ $$aUNRESTRICTED
000877618 981__ $$aI:(DE-Juel1)ICE-1-20170217